Advanced® 3900 Multi-Sample Osmometer, 130V/250V
- Designed to automate testing for laboratories processing moderate to high volumes of samples.
- Range; 0 to 4000 mOsm/kg H2O
- Holds up to three continuously loadable 10-sample cassettes.
- Osmometer start-up time: 3 - 10min.
- Repeatability: 0 to 400: ±2 mOsm/kg H2O (1 S.D.) | Resolution: ±1 mOsm/kg H2O.
- Manufacturer Part No: 3900
PLEASE NOTE: Product images and descriptions may not exactly represent the product. Prior to making your purchase, please confirm that the manufacturer part number shown above matches the product you seek. Returns are not allowed for such differences if the correct manufacturer part number is shipped.
Details
Advanced® Model 3900 Multi-Sample Osmometer. The Advanced® Model 3900 Multi-Sample Osmometer is designed to automate testing for laboratories processing moderate to high volumes of samples. Approximately 30 samples per hour at 73°F or 23°C; less at higher ambient temperature and in high range. Holds up to three continuously loadable 10-sample cassettes plus insertable single sample stat test. By using the industry-preferred method of freezing-point technology for an accurate determination of total concentration, combined with high, continuous throughput, the Advanced Instruments Model 3900 will provide your laboratory optimal efficiency, easily, accurately, and reliably. Drift is less than 1 unit per month plus 1 unit for every 9°F or 5°C ambient temperature change. One-year limited warranty on workmanship and all parts except glass, plastic and parts warranted by their makers. Sample Size: 0.2 - 0.3ml. Ranges - Low: 0 - 1550mOsm/kg H2O; - High: 1450 - 4000mOsm/kg H2O. Linearity: ±0.5% (0-1500); ±1% (1500-4000). Repeatability: 0 to 400: ±2 mOsm/kg H2O (1 S.D.). Resolution: ±1 mOsm/kg H2O. Communications: DTE EIA-232/V.24 (RS-232). Storage Temperature: -40°F to +113°F (-40°C to +70°C). Operating Temperature - Low Range: 64°F to 95°F (18°C to 35°C); - High Range: 64°F to 86°F (18°C to 30°C). Room Humidity: 5-80% (non-condensing). Start-up Time: 3 - 10min. Dimensions (W x H x D): 21.5 x 21.5 x 20cm. 100 - 130V or 200 - 250V. 350W. Shipping weight: 103lb. Advanced Instruments #: 3900.
Documents & Videos
Advanced® Model 3900 Multi-Sample Osmometer. The Advanced® Model 3900 Multi-Sample Osmometer is designed to automate testing for laboratories processing moderate to high volumes of samples. Approximately 30 samples per hour at 73°F or 23°C; less at higher ambient temperature and in high range. Holds up to three continuously loadable 10-sample cassettes plus insertable single sample stat test. By using the industry-preferred method of freezing-point technology for an accurate determination of total concentration, combined with high, continuous throughput, the Advanced Instruments Model 3900 will provide your laboratory optimal efficiency, easily, accurately, and reliably. Drift is less than 1 unit per month plus 1 unit for every 9°F or 5°C ambient temperature change. One-year limited warranty on workmanship and all parts except glass, plastic and parts warranted by their makers. Sample Size: 0.2 - 0.3ml. Ranges - Low: 0 - 1550mOsm/kg H2O; - High: 1450 - 4000mOsm/kg H2O. Linearity: ±0.5% (0-1500); ±1% (1500-4000). Repeatability: 0 to 400: ±2 mOsm/kg H2O (1 S.D.). Resolution: ±1 mOsm/kg H2O. Communications: DTE EIA-232/V.24 (RS-232). Storage Temperature: -40°F to +113°F (-40°C to +70°C). Operating Temperature - Low Range: 64°F to 95°F (18°C to 35°C); - High Range: 64°F to 86°F (18°C to 30°C). Room Humidity: 5-80% (non-condensing). Start-up Time: 3 - 10min. Dimensions (W x H x D): 21.5 x 21.5 x 20cm. 100 - 130V or 200 - 250V. 350W. Shipping weight: 103lb. Advanced Instruments #: 3900.