• Home
  • Atago MASTER-BCF Battery Coolant Checker Refractometer for Freezing Temperature in Fahrenheit, EG &

Atago MASTER-BCF Battery Coolant Checker Refractometer for Freezing Temperature in Fahrenheit, EG & PG Scales: 32 to -60°F32 to -50°F

  • Ethylene Glycol/Propylene Glycol - Freezing Temperature Scale Range: 32 to -60F°/0 to -60F°; Battery Fluid Specific Gravity (d20/20) Range: 1.150 to 1.300; Accuracies: 10F°/0.01
  • Exclusive scale for measuring specific gravity of battery fluid
  • Evaluates freezing temperature of ethylene glycol and propylene glycol
  • Graduated in °F
  • Accommodates salty and acid samples
  • Manufacturer Part No: 2932
(0) No Reviews yet

PLEASE NOTE: Product images and descriptions may not exactly represent the product. Prior to making your purchase, please confirm that the manufacturer part number shown above matches the product you seek. Returns are not allowed for such differences if the correct manufacturer part number is shipped.

Item Number: ATA-2932
$335.78

Sold in: Eaches

UnitMSRPYour PriceStock StatusQty
Each353.87335.78Lead Time

Details

This Atago industrial hand held refractometer has an exclusive scale for measuring specific gravity of battery fluid and evaluates the freezing temperature of ethylene glycol and propylene glycol which are used as antifreeze mixture in automobiles - thermal catalyst for solar power systems and other industrial applications. MASTER-BCF is the successor model to the conventional BC-3E. The scale is graduated in °F. Constructed with NEW material which is durable for salty and acid samples. Scale Range/Freezing Temperature Scale: E.G. 32 to -60°F; P.G. 32 to -50°F. Battery Fluid: 20/20; 1.150 to 1.300. Minimum Scale/Freezing temperature scale: E.G. 10°F; P.G. 10°F. Battery Fluid: d20/20; 0.01. Size & Weight: 3.2x3.4x 16.8cm - 90g. 1/Each. Atago #: 2932.

Documents & Videos

This Atago industrial hand held refractometer has an exclusive scale for measuring specific gravity of battery fluid and evaluates the freezing temperature of ethylene glycol and propylene glycol which are used as antifreeze mixture in automobiles - thermal catalyst for solar power systems and other industrial applications. MASTER-BCF is the successor model to the conventional BC-3E. The scale is graduated in °F. Constructed with NEW material which is durable for salty and acid samples. Scale Range/Freezing Temperature Scale: E.G. 32 to -60°F; P.G. 32 to -50°F. Battery Fluid: 20/20; 1.150 to 1.300. Minimum Scale/Freezing temperature scale: E.G. 10°F; P.G. 10°F. Battery Fluid: d20/20; 0.01. Size & Weight: 3.2x3.4x 16.8cm - 90g. 1/Each. Atago #: 2932.

Ratings & Reviews

No reviews available