Oakton 00652-48 Traceable® Conductivity & TDS Standard, 1,000uS, Individually Tested, 500mL Bottle

  • Traceable® Conductivity Standards, a Certified Reference Material, is 100% compatible with all makes of instruments and probes
  • Microsiemens/Micromhos: 1000; Megohms: 0.001; TDS/PPM: 666; capacity: 16oz; individually tested
  • Accuracy At 25°C: ±0.25 Microsiemen (Micromho) for the 1, 5, 10 values; ±0.25% for all other values
  • Bottle is labeled for calibrating conductivity (microsiemens/micromhos), resistivity (ohms), and dissolved solids (parts per million)
  • Bottle is supplied with step-by-step calibration instructions, individual temperature compensation chart, traceability information, and Traceable® Certificate
  • Manufacturer Part No: EW-00652-48
(0) No Reviews yet

PLEASE NOTE: Product images and descriptions may not exactly represent the product. Prior to making your purchase, please confirm that the manufacturer part number shown above matches the product you seek. Returns are not allowed for such differences if the correct manufacturer part number is shipped.

Item Number: OAK-00652-48
$100.12

Sold in: Eaches

UnitMSRPYour PriceStock StatusQty
Each106.00100.12Lead Time

New

Details

This Traceable® Conductivity Standards, a Certified Reference Material, is 100% compatible with all makes of instruments and probes. Traceable® Conductivity Standards are the most accurate available. Accuracy at 25°C is (±0.25 microsiemens for 1, 5, 10 microsiemen solution or ±0.25% for other solutions) or the uncertainty shown on the certificate, whichever is greater. Each bottle is labeled for calibrating conductivity (microsiemens/micromhos), resistivity (ohms), and dissolved solids (parts per million). This Certified reference material meets test requirements for Federal, State, and local agencies, CAP, ASTM, NCCLS, CLSI, ACS, CLIA, AOAC, EPA, APHA, AWWA, WEF, USGS, USP, and ISO. Traceable® Certified reference material complies with and is essential for use in these official methods: AOAC 973.40, EPA 120.1, standard method 2510 (APHA, AWWA, WEF), ISO 7888, DIN 38404, ASTM D1125, USGS I-1780, USP 645, and for A2LA/NVLAP accreditations/ISO 9000 certifications. Material may be used to calibrate all conductivity meters and to determine all conductivity cell constants. To assure accuracy an individually serial-numbered Traceable® Certificate is supplied to indicate traceability to standards provided by NIST (National Institute of Standards and Technology) and/or a National Standards Laboratory. Double A2LA accredited certification provides the highest achievable level of quality assurance, documentation, and accuracy. Certified Reference Materials are produced in an A2LA accredited ISO 17025 calibration laboratory by an A2LA accredited ISO Guide 34 reference material producer. Additional accreditations include ISO 31 (certificate content) and ISO 35 (statistical analysis), plus ISO 9001 (certified quality manufacturer). Each bottle is supplied with step-by-step calibration instructions, individual temperature compensation chart, traceability information, and Traceable® Certificate. Individually Tested. Capacity: 16oz. Accuracy At 25°C: ±0.25 Microsiemen (Micromho) For The 1, 5, 10 Values; ±0.25% For All Other Values. Microsiemens/Micromhos: 1000. Megohms: 0.001. TDS/PPM: 666. Oakton Instruments #: 00652-48.

Documents & Videos

This Traceable® Conductivity Standards, a Certified Reference Material, is 100% compatible with all makes of instruments and probes. Traceable® Conductivity Standards are the most accurate available. Accuracy at 25°C is (±0.25 microsiemens for 1, 5, 10 microsiemen solution or ±0.25% for other solutions) or the uncertainty shown on the certificate, whichever is greater. Each bottle is labeled for calibrating conductivity (microsiemens/micromhos), resistivity (ohms), and dissolved solids (parts per million). This Certified reference material meets test requirements for Federal, State, and local agencies, CAP, ASTM, NCCLS, CLSI, ACS, CLIA, AOAC, EPA, APHA, AWWA, WEF, USGS, USP, and ISO. Traceable® Certified reference material complies with and is essential for use in these official methods: AOAC 973.40, EPA 120.1, standard method 2510 (APHA, AWWA, WEF), ISO 7888, DIN 38404, ASTM D1125, USGS I-1780, USP 645, and for A2LA/NVLAP accreditations/ISO 9000 certifications. Material may be used to calibrate all conductivity meters and to determine all conductivity cell constants. To assure accuracy an individually serial-numbered Traceable® Certificate is supplied to indicate traceability to standards provided by NIST (National Institute of Standards and Technology) and/or a National Standards Laboratory. Double A2LA accredited certification provides the highest achievable level of quality assurance, documentation, and accuracy. Certified Reference Materials are produced in an A2LA accredited ISO 17025 calibration laboratory by an A2LA accredited ISO Guide 34 reference material producer. Additional accreditations include ISO 31 (certificate content) and ISO 35 (statistical analysis), plus ISO 9001 (certified quality manufacturer). Each bottle is supplied with step-by-step calibration instructions, individual temperature compensation chart, traceability information, and Traceable® Certificate. Individually Tested. Capacity: 16oz. Accuracy At 25°C: ±0.25 Microsiemen (Micromho) For The 1, 5, 10 Values; ±0.25% For All Other Values. Microsiemens/Micromhos: 1000. Megohms: 0.001. TDS/PPM: 666. Oakton Instruments #: 00652-48.

Ratings & Reviews

No reviews available

Be the first to Write a Review