  • Maximum speed: 16,400 rpm
  • Includes aluminum lid
  • 30-Place Rotor - Holds 1.5mL or 2.0mL centrifuge tubes
  • Autoclavable for 2 h at 140°C to eliminate prior contamination
  • Sold individually
  • Manufacturer Part No: EP-022636006
(0) No Reviews yet

PLEASE NOTE: Product images and descriptions may not exactly represent the product. Prior to making your purchase, please confirm that the manufacturer part number shown above matches the product you seek. Returns are not allowed for such differences if the correct manufacturer part number is shipped.

Item Number: C1788-2
This item is discontinued. Please contact customer service at 512.836.1667 if you would like assistance finding an alternative item.

Details

Eppendorf® Fixed-angle rotor F-45-30-11 for Centrifuge 5417 C or 5417 R comes with adapters for 0.2mL PCR tubes, 0.4mL centrifuge tubes, 0.5mL micro test tubes and 0.6mL tubes, Maximum rotational speed: 16,400 rpm (max. rcf: 25,000 x g ) Choose from standard 30 place rotor or aerosol-tight* centrifugation with 24-place Rotor FA-45-24-11 and 30-place Rotor FA-45-30-11, Rotors, rotor lids and adapters are autoclavable (121°C, 20 minutes), Aerosol-tight rotors and lids can be autoclaved for 2 h at 140°C to eliminate prior contamination, Acceleration/deceleration <11 s (30-place rotor max.rotational speed), Aerosol-tightness has been tested and approved in accordance with the procedure of Bennett et al. from the Centre for Applied Microbiology and Research in Porton Down, CAMR, Great Britain, and according to annex AA of the IEC 1010-2-020 safety standard. The test procedure simulates the accidental release of biological material (bacteria) inside the closed rotor or closed rectangular bucket. Air and swab samples are taken to ensure that no material is released from the closed rectangular buckets or closed rotor during operation. Eppendorf® #: 022636006.

Documents & Videos

Eppendorf® Fixed-angle rotor F-45-30-11 for Centrifuge 5417 C or 5417 R comes with adapters for 0.2mL PCR tubes, 0.4mL centrifuge tubes, 0.5mL micro test tubes and 0.6mL tubes, Maximum rotational speed: 16,400 rpm (max. rcf: 25,000 x g ) Choose from standard 30 place rotor or aerosol-tight* centrifugation with 24-place Rotor FA-45-24-11 and 30-place Rotor FA-45-30-11, Rotors, rotor lids and adapters are autoclavable (121°C, 20 minutes), Aerosol-tight rotors and lids can be autoclaved for 2 h at 140°C to eliminate prior contamination, Acceleration/deceleration <11 s (30-place rotor max.rotational speed), Aerosol-tightness has been tested and approved in accordance with the procedure of Bennett et al. from the Centre for Applied Microbiology and Research in Porton Down, CAMR, Great Britain, and according to annex AA of the IEC 1010-2-020 safety standard. The test procedure simulates the accidental release of biological material (bacteria) inside the closed rotor or closed rectangular bucket. Air and swab samples are taken to ensure that no material is released from the closed rectangular buckets or closed rotor during operation. Eppendorf® #: 022636006.

Ratings & Reviews

No reviews available