• Home
  • HANNA HI96771-11 Cal Check™ Standard Cuvettes for use with HI96771 Portable Free Chlorine Photomete

HANNA HI96771-11 Cal Check™ Standard Cuvettes for use with HI96771 Portable Free Chlorine Photometer (Ultra High Range)

  • The HI96771-11 Low Range Free Chlorine and Ultra High Range Chlorine CAL Check™ Standards provide a simple solution to calibrating and validating the HI96771 portable photometer
  • The standards are used for both the 0.00 to 5.00 mg/L (ppm) low range free chlorine and the 0 to 500 mg/L (ppm) ultra high chlorine range
  • This high quality set of standards is manufactured in Hanna Instrument's state-of-the-art facility and comes supplied with a Certificate of Analysis
  • The Certificate of Analysis provides the lot number, reference values, and expiration date for traceability when certifying the HI96771 photometer
  • Standard value of 1.00 ±0.02 mg/L for low range and 100 ±2 mg/L chlorine for ultra high range @ 25°C
  • Sold Individually
  • Manufacturer Part No: HI96771-11
(0) No Reviews yet

PLEASE NOTE: Product images and descriptions may not exactly represent the product. Prior to making your purchase, please confirm that the manufacturer part number shown above matches the product you seek. Returns are not allowed for such differences if the correct manufacturer part number is shipped.

Item Number: HAN-HI96771-11
$185.00

Sold in: Eaches

UnitMSRPYour PriceStock StatusQty
Each185.00185.00Lead Time

new

Details

HI96771-11 is a high quality set of calibration standards that allows users to validate and calibrate the HI96771 portable photometer that has a 0.00 to 5.00 mg/L (ppm) and 0 to 500 mg/L free chlorine range. The HI96771-11 includes one sealed “A” cuvette for zeroing the meter and one “B” cuvette that is used to validate or calibrate. An acceptable reading using the standards with the HI96771 is 1.00 ±0.03 mg/L for the low range and 100 ±3 mg/L chlorine for the ultra high range @ 25°C. The calibration set is produced in our state-of-the-art manufacturing facility using reagent grade chemicals in a temperature controlled environment.

Documents & Videos

HI96771-11 is a high quality set of calibration standards that allows users to validate and calibrate the HI96771 portable photometer that has a 0.00 to 5.00 mg/L (ppm) and 0 to 500 mg/L free chlorine range. The HI96771-11 includes one sealed “A” cuvette for zeroing the meter and one “B” cuvette that is used to validate or calibrate. An acceptable reading using the standards with the HI96771 is 1.00 ±0.03 mg/L for the low range and 100 ±3 mg/L chlorine for the ultra high range @ 25°C. The calibration set is produced in our state-of-the-art manufacturing facility using reagent grade chemicals in a temperature controlled environment.

Ratings & Reviews

No reviews available

Be the first to Write a Review