HANNA HI98703-01 EPA Compliant Portable Turbidity Meter with Fast Tracker™ Technology, Electrical: 115V

  • Manufacturer Part No: HI98703-01
(0) No Reviews yet

PLEASE NOTE: Product images and descriptions may not exactly represent the product. Prior to making your purchase, please confirm that the manufacturer part number shown above matches the product you seek. Returns are not allowed for such differences if the correct manufacturer part number is shipped.

Item Number: HAN-HI98703-01
$1,238.00

Sold in: Eaches

UnitMSRPYour PriceStock StatusQty
Each1,238.001,238.00Lead Time

New

Details

HANNA's new HI 98703 portable Turbidity Meter utilizes an EPA compliant tungsten light source and state-of-the-art optical system that allows consistently reliable and accurate measurements for turbidity. Users will appreciate the accuracy and sensitivity of this instrument, particularly at very low turbidity levels.To meet EPA reporting requirements these portable turbidimeters have an EPA compliance reading mode. HI 98703 meets all EPA requirements with regards to the Standard Methods for Turbidity Measurements. Turbidity is measured up to 1000 NTU. Depending on the measured sample and required accuracy, users can select normal measurement, continuous measurement or signal averaging. HI 98703 can be equipped with HANNA's (optional) Tag Identification System (TIS) which allows users to record the time and location of a specific measurement or series of measurements. Logged data can be downloaded to a PC through either USB or RS232 connections. Reliable performance of the instrument is validated using Hanna's exclusive Cal Check® system and our ready-made, NiST traceable chlorine standards. For turbidity, a two, three or four-point calibration is available using pre-set or user defined standards. Frequent Calibration isn't necessary as the system compensates for variations in the intensity of the light source. This portable turbidity meter features Good Laboratory Practice (GLP) functions allow traceability of calibration conditions including the time, date and last calibration points. At startup, the meter displays the percentage of remaining battery life. A 'low battery' warning message is also displayed on the LCD to avoid unexpected battery failure. This instruments is equipped with backlighting. The current date and time can be displayed on the LCD. Hanna #: HI 98703. • Range (Turbidity): 0.00 to 9.99 NTU; 10.0 to 99.9 NTU; 100 to 1000 NTU.• Range Selection (Turbidity): Automatic • Resolution (Turbidity): 0.01 NTU from 0.00 to 9.99 NTU; 0.1 NTU from 10.0 to 99.9 NTU; 1 NTU from 100 to 1000 NTU.• Accuracy Turbidity ±2% of reading plus 0.02 NTU • Repeatability: ±1% of reading or 0.02 NTU, whichever is greater.• Stray Light: < 0.02 NTU • Typical EMC Deviation: ±0.05 NTU • Light Detection: Silicon Photocell • Method (Turbidity): Ratio Nephelometric Method (90°), ratio of scattered and transmitted light; Adaptation of the USEPA Method 180.1 and Standard Method 2130 B. • Measuring Modes: Normal, Average, Continuous • Turbidity Standards 1, 10, 100 and 750 NTU • Typical EMC Deviation: ±0.05 mg/L • Light Source: Silicon photocell with 525 nm narrow band interference filters.• Calibration: Two, three or four-point calibration • Light Source: Tungsten filament lamp • Lamp Life: Greater than 100,000 readings • Display: 60 x 90 mm LCD with back light • Logging Memory: 200 records • Serial Interface: USB 1.1 or RS 232 • Environment: To 50°C (122°F); max 95% RH non-condensing • Power Supply: (4) 1.5V AA alkaline batteries or AC adapter • Auto Shut-Off: After 15 minutes of non-use • Dimensions: 224 x 87 x 77 mm (8.8 x 3.4 x 3.0”) • Weight: 512 g (18 oz.) The HI 98703 portable turbidity meter is furnished complete with:• Five Sample Cuvets and Caps• Calibration Cuvets (HI 98703-11)• Silicone Oil (HI 93703-58)• Tissue for wiping the cuvets• Five Tag holders with Tags (HI 920005)• Batteries (4 pcs.)• AC Adapter• Instruction Manual• Instrument Quality Certificate• Rigid Carrying Case. HANNA #: HI98703-01.

Documents & Videos

HANNA's new HI 98703 portable Turbidity Meter utilizes an EPA compliant tungsten light source and state-of-the-art optical system that allows consistently reliable and accurate measurements for turbidity. Users will appreciate the accuracy and sensitivity of this instrument, particularly at very low turbidity levels.To meet EPA reporting requirements these portable turbidimeters have an EPA compliance reading mode. HI 98703 meets all EPA requirements with regards to the Standard Methods for Turbidity Measurements. Turbidity is measured up to 1000 NTU. Depending on the measured sample and required accuracy, users can select normal measurement, continuous measurement or signal averaging. HI 98703 can be equipped with HANNA's (optional) Tag Identification System (TIS) which allows users to record the time and location of a specific measurement or series of measurements. Logged data can be downloaded to a PC through either USB or RS232 connections. Reliable performance of the instrument is validated using Hanna's exclusive Cal Check® system and our ready-made, NiST traceable chlorine standards. For turbidity, a two, three or four-point calibration is available using pre-set or user defined standards. Frequent Calibration isn't necessary as the system compensates for variations in the intensity of the light source. This portable turbidity meter features Good Laboratory Practice (GLP) functions allow traceability of calibration conditions including the time, date and last calibration points. At startup, the meter displays the percentage of remaining battery life. A 'low battery' warning message is also displayed on the LCD to avoid unexpected battery failure. This instruments is equipped with backlighting. The current date and time can be displayed on the LCD. Hanna #: HI 98703. • Range (Turbidity): 0.00 to 9.99 NTU; 10.0 to 99.9 NTU; 100 to 1000 NTU.• Range Selection (Turbidity): Automatic • Resolution (Turbidity): 0.01 NTU from 0.00 to 9.99 NTU; 0.1 NTU from 10.0 to 99.9 NTU; 1 NTU from 100 to 1000 NTU.• Accuracy Turbidity ±2% of reading plus 0.02 NTU • Repeatability: ±1% of reading or 0.02 NTU, whichever is greater.• Stray Light: < 0.02 NTU • Typical EMC Deviation: ±0.05 NTU • Light Detection: Silicon Photocell • Method (Turbidity): Ratio Nephelometric Method (90°), ratio of scattered and transmitted light; Adaptation of the USEPA Method 180.1 and Standard Method 2130 B. • Measuring Modes: Normal, Average, Continuous • Turbidity Standards 1, 10, 100 and 750 NTU • Typical EMC Deviation: ±0.05 mg/L • Light Source: Silicon photocell with 525 nm narrow band interference filters.• Calibration: Two, three or four-point calibration • Light Source: Tungsten filament lamp • Lamp Life: Greater than 100,000 readings • Display: 60 x 90 mm LCD with back light • Logging Memory: 200 records • Serial Interface: USB 1.1 or RS 232 • Environment: To 50°C (122°F); max 95% RH non-condensing • Power Supply: (4) 1.5V AA alkaline batteries or AC adapter • Auto Shut-Off: After 15 minutes of non-use • Dimensions: 224 x 87 x 77 mm (8.8 x 3.4 x 3.0”) • Weight: 512 g (18 oz.) The HI 98703 portable turbidity meter is furnished complete with:• Five Sample Cuvets and Caps• Calibration Cuvets (HI 98703-11)• Silicone Oil (HI 93703-58)• Tissue for wiping the cuvets• Five Tag holders with Tags (HI 920005)• Batteries (4 pcs.)• AC Adapter• Instruction Manual• Instrument Quality Certificate• Rigid Carrying Case. HANNA #: HI98703-01.

Ratings & Reviews

No reviews available

Be the first to Write a Review