LAUDA® LWG 859 Model WKL 900 Recirculating Chiller, Air Cooled, Range: -20 To 40°C, Cooling Output at 20°C: 0.95kW, Max Flow Rate: 30L/Min, 208-220V/60Hz

Item is discontinued. No replacement
  • Working Temp Range: -20 to 40°C | Filling Volume: 8 to 12L | Electrical: 208-220V/60Hz | Air-Cooled Design
  • Max Pump Pressure: 1.0bar | Max Pump Flow: 30L/min | Cooling Output at 20°C: 0.95kW | Dimensions: 350 x 480 x 595mm
  • LED display and 3-button operation. Features a submersible pump that eliminates seal problems at the pump shaft.
  • LAUDA® recirculating chillers provide a constant temperature and allow constant flow of lab reasearch and production irrespective of the time of year and pressure fluctuations
  • Designed for laboratory use with rotary evaporators, Soxhlet extractors, X-ray units, Refractometers and Distilling Apparatus.
  • Sold individually
  • Manufacturer Part No: LWG 859
(0) No Reviews yet

PLEASE NOTE: Product images and descriptions may not exactly represent the product. Prior to making your purchase, please confirm that the manufacturer part number shown above matches the product you seek. Returns are not allowed for such differences if the correct manufacturer part number is shipped.

Item Number: LAU-LWG 859
This item is discontinued. Please contact customer service at 512.836.1667 if you would like assistance finding an alternative item.

Details

This air-cooled WKL 900 circulation chiller with a filling volume of 8 to 12L has a closed cooler circuit for continuous nonstop work in research production at temperatures from -20 to 40°C. It is used where operating heat has to be discharged reliably and quickly in chemical production processes or from technical systems in harsh, constant use environments. Unlike cooling with tap water, this chilling circulator provides a constant temperature irrespective of the time of year and pressure fluctuations. The independent cooling-water system instead of a central cooling-water supply avoids the leakage of substances that are hazardous to the environment. The water savings also protects the environment and significantly reduces operating costs. The WKL 900 has an LED display and a 3-button operation, and features a submersible pump that eliminates seal problems at the pump shaft. Standard accessories include M16 x 1 pump connection threads, nipples, and screw caps. Applications include rotary evaporators and Soxhlet systems, analytical devices such as electron microscopes, X-ray units, refractometers, distilling systems, X-ray control systems such as at airports and semiconductor systems, control of cooling traps such as in the drying of gasses, and central cooling water supplies for complete laboratories to replace cooling with tap water. Working Temperature Range: -20 To 40°C. Resolution Of Setting: 0.1 To 1.0°C. Control: Compressor On/Off. Temperature Stability: +/- 1.0K. Effective Cooling Output At 20°C: 0.95kW. Effective Cooling Output At 0°C: 0.64kW. Effective Cooling Output At -20°C: 0.15kW. Pump Connection Thread: M16 x 1. Nipple Diameter: 10mm. Maximum Pump Pressure: 1.0bar. Maximum Pump Flow: 30L/min. For Tubings: 1/2in. Filling Volume: 8 To 12L. Dimensions: 350 x 480 x 595mm. Pressure Measurement/Parameter: No. Protection Level: IP32. Noise Level: 54dB(A). Additional Feature: Level Indication. Power Supply: 208-220V/60Hz. Weight: 46kg. Loading: 0.8kW. Lauda® #: LWG 859.

Documents & Videos

This air-cooled WKL 900 circulation chiller with a filling volume of 8 to 12L has a closed cooler circuit for continuous nonstop work in research production at temperatures from -20 to 40°C. It is used where operating heat has to be discharged reliably and quickly in chemical production processes or from technical systems in harsh, constant use environments. Unlike cooling with tap water, this chilling circulator provides a constant temperature irrespective of the time of year and pressure fluctuations. The independent cooling-water system instead of a central cooling-water supply avoids the leakage of substances that are hazardous to the environment. The water savings also protects the environment and significantly reduces operating costs. The WKL 900 has an LED display and a 3-button operation, and features a submersible pump that eliminates seal problems at the pump shaft. Standard accessories include M16 x 1 pump connection threads, nipples, and screw caps. Applications include rotary evaporators and Soxhlet systems, analytical devices such as electron microscopes, X-ray units, refractometers, distilling systems, X-ray control systems such as at airports and semiconductor systems, control of cooling traps such as in the drying of gasses, and central cooling water supplies for complete laboratories to replace cooling with tap water. Working Temperature Range: -20 To 40°C. Resolution Of Setting: 0.1 To 1.0°C. Control: Compressor On/Off. Temperature Stability: +/- 1.0K. Effective Cooling Output At 20°C: 0.95kW. Effective Cooling Output At 0°C: 0.64kW. Effective Cooling Output At -20°C: 0.15kW. Pump Connection Thread: M16 x 1. Nipple Diameter: 10mm. Maximum Pump Pressure: 1.0bar. Maximum Pump Flow: 30L/min. For Tubings: 1/2in. Filling Volume: 8 To 12L. Dimensions: 350 x 480 x 595mm. Pressure Measurement/Parameter: No. Protection Level: IP32. Noise Level: 54dB(A). Additional Feature: Level Indication. Power Supply: 208-220V/60Hz. Weight: 46kg. Loading: 0.8kW. Lauda® #: LWG 859.

Ratings & Reviews