PLEASE NOTE: Product images and descriptions may not exactly represent the product. Prior to making your purchase, please confirm that the manufacturer part number shown above matches the product you seek. Returns are not allowed for such differences if the correct manufacturer part number is shipped.
Details
Product Specifications
TEST | SPECIFICATION |
For Laboratory,Research,or Manufacturing Use | |
ACS - Assay (CH₃OH) (by GC) | >= 99.9 % |
Carbonyl Compounds - Acetaldehyde | <= 0.001 % |
Carbonyl Compounds - Acetone | <= 0.001 % |
Carbonyl Compounds - Formaldehyde | <= 0.001 % |
Color (APHA) | <= 10 |
Residue after Evaporation | <= 0.0002 % |
Solubility in H₂O | Passes Test |
Substances Darkened by H₂SO₄ | Passes Test |
Substances Reducing Permanganate | Passes Test |
Titrable Acid (meq/g) | <= 0.0003 |
Titrable Base (meq/g) | <= 0.0002 |
Water (H₂O)(by Karl Fischer titrn) | <= 0.05 % |
Ultraviolet Absorbance (1.00-cm cell vs. water) - 205 nm | <= 1.00 |
Ultraviolet Absorbance (1.00-cm cell vs. water) - 210 nm | <= 0.80 |
Ultraviolet Absorbance (1.00-cm cell vs. water) - 220 nm | <= 0.25 |
Ultraviolet Absorbance (1.00-cm cell vs. water) - 230 nm | <= 0.20 |
Ultraviolet Absorbance (1.00-cm cell vs. water) - 240 nm | <= 0.05 |
Ultraviolet Absorbance (1.00-cm cell vs. water) - 254 nm | <= 0.01 |
Ultraviolet Absorbance (1.00-cm cell vs. water) - 260 nm | <= 0.04 |
Ultraviolet Absorbance (1.00-cm cell vs. water) - 280 nm | <= 0.005 |
Ultraviolet Absorbance (1.00-cm cell vs. water) - 280 - 400 nm | <= 0.01 |
Ultraviolet Absorbance (1.00-cm cell vs. water) - 350 nm | <= 0.005 |
Ultraviolet Absorbance (1.00-cm cell vs. water): | Passes Test |
HPLC Gradient Elution (No Peak Greater than 25% of Full Scale)(0.005 au) | Passes Test |
Appearance (clear, colorless liquid) | |
Filtered through a 0.2 micron filter. |
Documents & Videos
Product Specifications
TEST | SPECIFICATION |
For Laboratory,Research,or Manufacturing Use | |
ACS - Assay (CH₃OH) (by GC) | >= 99.9 % |
Carbonyl Compounds - Acetaldehyde | <= 0.001 % |
Carbonyl Compounds - Acetone | <= 0.001 % |
Carbonyl Compounds - Formaldehyde | <= 0.001 % |
Color (APHA) | <= 10 |
Residue after Evaporation | <= 0.0002 % |
Solubility in H₂O | Passes Test |
Substances Darkened by H₂SO₄ | Passes Test |
Substances Reducing Permanganate | Passes Test |
Titrable Acid (meq/g) | <= 0.0003 |
Titrable Base (meq/g) | <= 0.0002 |
Water (H₂O)(by Karl Fischer titrn) | <= 0.05 % |
Ultraviolet Absorbance (1.00-cm cell vs. water) - 205 nm | <= 1.00 |
Ultraviolet Absorbance (1.00-cm cell vs. water) - 210 nm | <= 0.80 |
Ultraviolet Absorbance (1.00-cm cell vs. water) - 220 nm | <= 0.25 |
Ultraviolet Absorbance (1.00-cm cell vs. water) - 230 nm | <= 0.20 |
Ultraviolet Absorbance (1.00-cm cell vs. water) - 240 nm | <= 0.05 |
Ultraviolet Absorbance (1.00-cm cell vs. water) - 254 nm | <= 0.01 |
Ultraviolet Absorbance (1.00-cm cell vs. water) - 260 nm | <= 0.04 |
Ultraviolet Absorbance (1.00-cm cell vs. water) - 280 nm | <= 0.005 |
Ultraviolet Absorbance (1.00-cm cell vs. water) - 280 - 400 nm | <= 0.01 |
Ultraviolet Absorbance (1.00-cm cell vs. water) - 350 nm | <= 0.005 |
Ultraviolet Absorbance (1.00-cm cell vs. water): | Passes Test |
HPLC Gradient Elution (No Peak Greater than 25% of Full Scale)(0.005 au) | Passes Test |
Appearance (clear, colorless liquid) | |
Filtered through a 0.2 micron filter. |