Oakton Instruments® WD-35419-22 Ion 700 Benchtop pH Meter with Electrode Stand, Parameters: pH/mV/ISE/Temperature, 110/240V
- pH/ISE Meter and Electrode Stand Only, 110/220V 50/60Hz
- Measures pH, mV, relative mV, and temperature while adding ion measurement capabilities. Ion concentration is directly read in ppm for easy use.
- Features HOLD, ATC, recorder output, and electrode diagnostics. Automatic temperature compensation (ATC)
- Five-point pH calibration, with automatic buffer recognition for both USA and NIST required calibration.
- Meter accepts pH, ORP, or ion-selective electrodes with BNC connetion.
- Sold individually
- Manufacturer Part No: EW-35419-22
PLEASE NOTE: Product images and descriptions may not exactly represent the product. Prior to making your purchase, please confirm that the manufacturer part number shown above matches the product you seek. Returns are not allowed for such differences if the correct manufacturer part number is shipped.
Details
The Oakton Ion 700 meter measures pH, mV, relative mV, and temperature while adding ion measurement capabilities. Ion concentration is directly read in ppm for easy use. Verify electrode operation while taking measurements with the dual ppm and mV display. Up to three ion-concentration standards (choose from 0.1, 1.0, 10.0, 100.0, or 1000.0 ppm) may be calibrated.
The easy-to-use, microprocessor-based meter features HOLD, ATC, recorder output, and electrode diagnostics. Automatic temperature compensation (ATC) maintains reading accuracy even with fluctuating temperatures. Five-point pH calibration, with automatic buffer recognition for both USA (pH 1.68, 4.01, 7.00, 10.01, 12.45) and NIST (pH 1.68, 4.01, 6.86, 9.18, 12.45) pH buffers, makes for easy calibration no matter which requirement you need to meet. The convenient pull-out quick reference card keeps procedures handy at all times. The large, dual-display LCD provides excellent visibility—even from a distance. Meter accepts pH, ORP, or ion-selective electrodes with BNC connetion.
- Custom 3-1/4 x 2-7/16-Inch LCD display
- Small size conserves valuable benchspace
- Store and recall up to 100 data sets
Measures | pH, mV, Ion, and Temperature (°C or F) |
pHRange | 0.00 to 14.00 pH |
pHResolution | 0.01 pH |
pHAccuracy | ±0.01 pH |
pHCalibration | Up to 5 points (USA: 1.68,4.01, 7.00, 10.01, 12.45 or NIST: 1.68,4.01, 6.86, 9.18, 12.45) with autobuffer recognition |
mVRange | ±2000 mV |
mVResolution | 0.1 within 199.9 mV, 1 beyond 200 mV |
mVAccuracy | ±0.2 within 199.9mV, ±2 beyond 200 mV |
mVCalibration | Offset up to ±150 mV |
IonRange | 0.01 to 2000 ppm |
IonResolution | 0.01 ppm from 0.01 to 0.99 ppm 0.1 ppm from 1.0 to 199.9 ppm 1 ppm from 200 to 2000 ppm |
IonAccuracy | ±0.5% of reading FS (mono-valent) ±1.0% of reading FS (di-valent) |
IonCalibration | From 2 to 5 consecutive points 0.1, 1.0, 10.0, 100.0, or 1000.0 ppm |
TemperatureRange | 32 to 100°F (0.0 to 100.0°C) |
TemperatureResolution | 0.1 °F or C |
TemperatureAccuracy | ±0.3 °F or C |
TemperatureCalibration | Offset 0.1°C increments up to ±5°C/±9°F |
Memory | Up to 100 data sets |
Dimensions | 6 1/8" x 6 7/8" x 2 3/4" (15.5 x 17.5 x 6.9 cm) |
Documents & Videos
The Oakton Ion 700 meter measures pH, mV, relative mV, and temperature while adding ion measurement capabilities. Ion concentration is directly read in ppm for easy use. Verify electrode operation while taking measurements with the dual ppm and mV display. Up to three ion-concentration standards (choose from 0.1, 1.0, 10.0, 100.0, or 1000.0 ppm) may be calibrated.
The easy-to-use, microprocessor-based meter features HOLD, ATC, recorder output, and electrode diagnostics. Automatic temperature compensation (ATC) maintains reading accuracy even with fluctuating temperatures. Five-point pH calibration, with automatic buffer recognition for both USA (pH 1.68, 4.01, 7.00, 10.01, 12.45) and NIST (pH 1.68, 4.01, 6.86, 9.18, 12.45) pH buffers, makes for easy calibration no matter which requirement you need to meet. The convenient pull-out quick reference card keeps procedures handy at all times. The large, dual-display LCD provides excellent visibility—even from a distance. Meter accepts pH, ORP, or ion-selective electrodes with BNC connetion.
- Custom 3-1/4 x 2-7/16-Inch LCD display
- Small size conserves valuable benchspace
- Store and recall up to 100 data sets
Measures | pH, mV, Ion, and Temperature (°C or F) |
pHRange | 0.00 to 14.00 pH |
pHResolution | 0.01 pH |
pHAccuracy | ±0.01 pH |
pHCalibration | Up to 5 points (USA: 1.68,4.01, 7.00, 10.01, 12.45 or NIST: 1.68,4.01, 6.86, 9.18, 12.45) with autobuffer recognition |
mVRange | ±2000 mV |
mVResolution | 0.1 within 199.9 mV, 1 beyond 200 mV |
mVAccuracy | ±0.2 within 199.9mV, ±2 beyond 200 mV |
mVCalibration | Offset up to ±150 mV |
IonRange | 0.01 to 2000 ppm |
IonResolution | 0.01 ppm from 0.01 to 0.99 ppm 0.1 ppm from 1.0 to 199.9 ppm 1 ppm from 200 to 2000 ppm |
IonAccuracy | ±0.5% of reading FS (mono-valent) ±1.0% of reading FS (di-valent) |
IonCalibration | From 2 to 5 consecutive points 0.1, 1.0, 10.0, 100.0, or 1000.0 ppm |
TemperatureRange | 32 to 100°F (0.0 to 100.0°C) |
TemperatureResolution | 0.1 °F or C |
TemperatureAccuracy | ±0.3 °F or C |
TemperatureCalibration | Offset 0.1°C increments up to ±5°C/±9°F |
Memory | Up to 100 data sets |
Dimensions | 6 1/8" x 6 7/8" x 2 3/4" (15.5 x 17.5 x 6.9 cm) |