Oakton® WD-35433-00 CD 650 Portable Waterproof Multiparameter Meter with 2-Electrode Conductivity Cell Probe & DO Probe, Parameters: Conductivity/TDS/Temperature/DO/Resistivity/NaCl

  • Includes meter, conductivity cell 35408-57, DO probe 35640-50 and batteries
  • Great for salt water testing; durable waterproof and dustproof design with IP67 rating; push-button calibration for all parameters
  • Large backlit graphic display; user-settable 'calibration due' alarm
  • Built-in real-time clock; store up to 500 data sets
  • Set point alarms; research-grade accuracy; electrode status indicator; password protection
  • Manufacturer Part No: EW-35433-00
(0) No Reviews yet

PLEASE NOTE: Product images and descriptions may not exactly represent the product. Prior to making your purchase, please confirm that the manufacturer part number shown above matches the product you seek. Returns are not allowed for such differences if the correct manufacturer part number is shipped.

Item Number: OAK-WD-35433-00

New

Details

Even with no probes attached and the battery compartment open. 6 points each for pH and conductivity; 3 points for DO. Multi-line display with electrode status indicator - calibration data and more. Time-and-date stamping meets Good Laboratory Practice (GLP) standards. Infrared IrDA wireless technology makes PC downloading convenient and easy. Audible warning when readings are outside set points limit. Resolution to 0.001 pH and accuracy to +/-0.002 pH. Calibration data provides electrode diagnostic tool. Security for calibration and setup menus. TDS factor: 0.40 to 1.00 - cell constant: 0.100 to 10.000 - DO salinity correction range: 0.0 to 50.0 ppt; resolution: 0.1 ppt - DO pressure correction Range: 500 to 1499 mm Hg - 66.6 to 199.9 kPa Resolution: 1 mm Hg - 0.1 kPa - memory: up to 500 sets with GLP date and time - output: infrared - IrDA - real-time clock: time-and-date stamp on calibration and stored data - temperature normalization: 15 or 30 degree C - temperature compensation: automatic or manual (selectable) - from 0 to 100 degree C - ambient operating temperature: 0 to 50 degree C (32 to 122 degree F) - power: 4 1.5V AA batteries (included) or optional universal AC adapter - up to 200 hours continuous use - meter measures: 7.25' length by 3.25' width by 2.25' height - boxed measures: 9.2' length by 9.2' width by 2.75' height - meter weight: 1.0 lb (0.45 kg); boxed weight: 2.0 lb (0.9 kg). Conductivity range is 0 to 500.0 mS - TDS range is 0 to 500 ppt - salinity range is 0 to 80 ppt - resistivity range is 0 to 20.00 milliohm - DO range is 0.00 to 90.00 mg/L (ppm) - 0.0 to 600.0 percent. Conductivity resolution is 0.05 percent full-scale - TDS resolution is 0.05 percent full-scale - DO resolution is 0.01 mg/L (ppm) - 0.1 percent - temperature resolution is 0.1 degree C (0.1 degree F). Conductivity accuracy is +/-1 percent full-scale - TDS accuracy is +/-1 percent full-scale - DO accuracy is +/-0.2 mg/L; +/-2 percent.

Documents & Videos

Even with no probes attached and the battery compartment open. 6 points each for pH and conductivity; 3 points for DO. Multi-line display with electrode status indicator - calibration data and more. Time-and-date stamping meets Good Laboratory Practice (GLP) standards. Infrared IrDA wireless technology makes PC downloading convenient and easy. Audible warning when readings are outside set points limit. Resolution to 0.001 pH and accuracy to +/-0.002 pH. Calibration data provides electrode diagnostic tool. Security for calibration and setup menus. TDS factor: 0.40 to 1.00 - cell constant: 0.100 to 10.000 - DO salinity correction range: 0.0 to 50.0 ppt; resolution: 0.1 ppt - DO pressure correction Range: 500 to 1499 mm Hg - 66.6 to 199.9 kPa Resolution: 1 mm Hg - 0.1 kPa - memory: up to 500 sets with GLP date and time - output: infrared - IrDA - real-time clock: time-and-date stamp on calibration and stored data - temperature normalization: 15 or 30 degree C - temperature compensation: automatic or manual (selectable) - from 0 to 100 degree C - ambient operating temperature: 0 to 50 degree C (32 to 122 degree F) - power: 4 1.5V AA batteries (included) or optional universal AC adapter - up to 200 hours continuous use - meter measures: 7.25' length by 3.25' width by 2.25' height - boxed measures: 9.2' length by 9.2' width by 2.75' height - meter weight: 1.0 lb (0.45 kg); boxed weight: 2.0 lb (0.9 kg). Conductivity range is 0 to 500.0 mS - TDS range is 0 to 500 ppt - salinity range is 0 to 80 ppt - resistivity range is 0 to 20.00 milliohm - DO range is 0.00 to 90.00 mg/L (ppm) - 0.0 to 600.0 percent. Conductivity resolution is 0.05 percent full-scale - TDS resolution is 0.05 percent full-scale - DO resolution is 0.01 mg/L (ppm) - 0.1 percent - temperature resolution is 0.1 degree C (0.1 degree F). Conductivity accuracy is +/-1 percent full-scale - TDS accuracy is +/-1 percent full-scale - DO accuracy is +/-0.2 mg/L; +/-2 percent.

Ratings & Reviews

No reviews available

Be the first to Write a Review