• Home
  • Thermo Scientific Barnstead Nanopure Analytical Standard Type I Ultrapure Water Purification System

Thermo Scientific Barnstead Nanopure Analytical Standard Type I Ultrapure Water Purification System With Total Organic Carbon (TOC) Monitor Analyzer

  • Capacity: 30L
  • Material: fluorinated polyethylene
  • Standard storage reservoir eliminates leaching of organic materials for unparalleled protection from contamination
  • Integrated dual wave-length UV lamp controls bacteria and ensures organic-free water on-demand
  • The integrated distribution pump operates at the level required by usage for efficient operation and lower maintenance
  • Sold individually
  • Manufacturer Part No: TS-D11941
(0) No Reviews yet

PLEASE NOTE: Product images and descriptions may not exactly represent the product. Prior to making your purchase, please confirm that the manufacturer part number shown above matches the product you seek. Returns are not allowed for such differences if the correct manufacturer part number is shipped.

Item Number: D2541-3
This item is discontinued. Please contact customer service at 512.836.1667 if you would like assistance finding an alternative item.

Details

This Thermo Scientific Barnstead Nanopure Analytical ultrapure water purification system with total organic carbon (TOC) analyzer features continuous recirculation to maintain the highest water purity during periods of inactivity. The automatic system notification indicates when water quality falls below the programmable set point. The TOC analyzer continuously monitors and records TOC and resistivity data in real-time, so you can be sure that your ultrapure water exceeds the most stringent requirements for your sensitive application. A sample of water is pulled into the TOC analyzer every 3.5 minutes. Choose one-touch manual or automatic dispense, as well as volumetric or timed modes. The multilingual intuitive display provides easy access to resistivity, conductivity, TOC, and temperature readings. A diagnostic menu evaluates important system components and alerts if a problem exists. Final filtration is performed with an absolute 0.2µm gamma irradiated filter; the naturally hydrophilic hollow fibers provide high surface area for longer filter life and fast rinse up to desired purity levels. Exceeds quantitative specifications for Type 1 water as described in ASTM D1193, ISO 3696, and CLSI-CLRW. Applications include buffer preparation, AA, and titration solutions. Includes a wall bracket and cleaning syringe. System Design: Nanopure Analytical Standard Base Unit With Total Organic Carbon (TOC) Monitor Analyzer. Resistivity at 25°C: 18.2 Mega-ohm/cm. Total Organic Carbon: 5-10ppb. Bacteria: Less Than 1 CFU/mL. Overall Dimensions (W x H x D): 13.5 x 19.5 x 17.5 Inches (34.3 x 49.5 x 44.5cm). Feed Water Pressure: 100psig (6.9 bar). Inlet Water Temperature: 40-104°F (4-40°C). Voltage: 90-240 VAC, 100VA, 47-63Hz, 1 Phase. Flow Rate: Up To 2L/hr. TOC Volume Per Measurement: 10-15mL Per Reading, Dispensed To Drain. TOC Cycle Interval: Measurements Taken In 3.5 Minute Cycles. TOC Range: 1-250ppb (At 10 Mega-ohm-cm Resistivity). TOC Resolution: 1ppb. TOC Accuracy: +/- 1ppb Or 15% Of Reading, Whichever Is Greater. Per each. Barnstead #: D11941.

Documents & Videos

This Thermo Scientific Barnstead Nanopure Analytical ultrapure water purification system with total organic carbon (TOC) analyzer features continuous recirculation to maintain the highest water purity during periods of inactivity. The automatic system notification indicates when water quality falls below the programmable set point. The TOC analyzer continuously monitors and records TOC and resistivity data in real-time, so you can be sure that your ultrapure water exceeds the most stringent requirements for your sensitive application. A sample of water is pulled into the TOC analyzer every 3.5 minutes. Choose one-touch manual or automatic dispense, as well as volumetric or timed modes. The multilingual intuitive display provides easy access to resistivity, conductivity, TOC, and temperature readings. A diagnostic menu evaluates important system components and alerts if a problem exists. Final filtration is performed with an absolute 0.2µm gamma irradiated filter; the naturally hydrophilic hollow fibers provide high surface area for longer filter life and fast rinse up to desired purity levels. Exceeds quantitative specifications for Type 1 water as described in ASTM D1193, ISO 3696, and CLSI-CLRW. Applications include buffer preparation, AA, and titration solutions. Includes a wall bracket and cleaning syringe. System Design: Nanopure Analytical Standard Base Unit With Total Organic Carbon (TOC) Monitor Analyzer. Resistivity at 25°C: 18.2 Mega-ohm/cm. Total Organic Carbon: 5-10ppb. Bacteria: Less Than 1 CFU/mL. Overall Dimensions (W x H x D): 13.5 x 19.5 x 17.5 Inches (34.3 x 49.5 x 44.5cm). Feed Water Pressure: 100psig (6.9 bar). Inlet Water Temperature: 40-104°F (4-40°C). Voltage: 90-240 VAC, 100VA, 47-63Hz, 1 Phase. Flow Rate: Up To 2L/hr. TOC Volume Per Measurement: 10-15mL Per Reading, Dispensed To Drain. TOC Cycle Interval: Measurements Taken In 3.5 Minute Cycles. TOC Range: 1-250ppb (At 10 Mega-ohm-cm Resistivity). TOC Resolution: 1ppb. TOC Accuracy: +/- 1ppb Or 15% Of Reading, Whichever Is Greater. Per each. Barnstead #: D11941.

Ratings & Reviews

No reviews available

Be the first to Write a Review