Thermo Scientific Orion STARA2147 Orion Star™ A214 Multiparameter Meter and Fluoride ISE Kit, Parameters: pH/ISE/mV/Temp

  • Thermo Scientific Orion Star A214 pH/ISE/mV/Temperature Benchtop meter and Fluoride ISE kit; meter features a large, backlit graphic LCD display and AUTO-READ™; includes universal power adapter
  • Includes ROSS Ultra Glass Refillable pH Electrode, a stainless steel ATC probe, a combination fluoride electrode, and an automatic stirrer and paddle
  • Comes 475mL each of fluoride 1ppm with TISAB II standard, fluoride 2ppm with TISAB II standard, fluoride 10ppm with TISAB II standard; also includes 1-Gallon (3.8L) TISAB II for fluoride electrode
  • Up to five point ISE calibration with advanced features such as timed end point, linear point-to-point, non-linear selectable auto-blank and low-concentration range stability
  • Non-volatile memory holds up to 2000 data points with time and date stamp; electrode arm and newly-designed probe holder make it easier to maintain and place probes into samples
  • Kit
  • Manufacturer Part No: ORI-STARA2147
(0) No Reviews yet

PLEASE NOTE: Product images and descriptions may not exactly represent the product. Prior to making your purchase, please confirm that the manufacturer part number shown above matches the product you seek. Returns are not allowed for such differences if the correct manufacturer part number is shipped.

Item Number: ORI-STARA2147
$3,349.64

Sold in: Kits

UnitMSRPYour PriceStock StatusQty
Kit3,530.003,349.64Lead Time

New

Details

This Thermo Scientific Orion Star A214 pH/ISE/mV/Temperature Benchtop meter and Fluoride ISE kit is the ideal choice for any lab. The kit includes the 8102BNUWP ROSS Ultra Glass Refillable pH Electrode, a general purpose, top performance glass body combination electrode with waterproof BNC connector for precise pH determinations. The pH response is independent of temperature changes and can be used on any pH meter with a BNC connection. The kit also comes with the 927007MD stainless steel ATC probe (Mini-DIN connector; 1m cable) which automatically corrects pH measurements for variation in electrode slope due to temperature change, the 9609BNWP combination fluoride electrode which measure free fluoride ions in aqueous solutions quickly, simply, accurately and economically, and the 096019 automatic stirrer and paddle for use with Orion Star Meters and Orion 960 Titrator PLUS System which stirs samples for better accuracy and without having to deal with a separate stir plate and stir bar (fits Swing Arm Electrode Holder 96019). Kit also comes with the 040906 Fluoride 1ppm with TISAB II standard (475mL), the 040907 Fluoride 2ppm with TISAB II standard (475mL), the 040908 475mL Fluoride 10ppm with TISAB II standard (475mL), and the 940909 1-Gallon (3.8L) TISAB II for Fluoride electrode. The meter’s large, backlit graphic LCD display shows pH/mV/RmV/ISE results and temperature along with electrode status, time, date, sample ID, user ID and calibration points. For advanced users, features such as stability and averaging choices provide additional options. Anyone can use this meter with its plain language screen prompts, soft keys that update for easy selection and a multilanguage interface that supports English, Spanish, French, Italian, German and Chinese. The AUTO-READ™ locks in the stable reading on your screen, ready indicator alerts when readings are stable and timed reading gathers data in specific time intervals. Up to five point pH calibration with automatic recognition for USA/NIST and DIN buffers. Whether you use ISE infrequently or have multiple samples every day – up to five point ISE calibration with advanced features such as timed end point, linear point-to-point, non-linear selectable auto-blank and low-concentration range stability. Fix errors without a complete recalibration with the calibration editing function. The non-volatile memory holds up to 2000 data points with time and date stamp. Easily transfer data and keep meter software up-to-date with the USB and RS232 ports and complimentary data analysis software. Mix samples without a stir plate with direct control of the Orion Star stirrer probe (096019, sold separately). Included electrode arm and newly-designed probe holder make it easier to maintain and place probes into samples. Works with almost every AC power source with the included universal power adapter, or use four AA batteries (sold separately) to run the meter on DC power. IP54-rated housing handles splashes and is wall-mountable if table space is a problem. Three year meter replacement warranty. Certifications: CE, TUV, FCC Class A limits. pH Mode Range: -2.000 to 20.000. pH Mode Resolution: 0.1, 0.01, 0.001. pH Mode Relative Accuracy: ±0.002 pH Mode Calibration Points: up to 5. ISE Mode Range: 0 to 19999 in ppm, M, mg/L, %, ppb or unitless. ISE Mode Resolution: up to 3 significant digits. ISE Mode Relative Accuracy: ±0.2 mV or ±0.5% of reading, whichever is greater. ISE Mode Calibration Points: up to 5; Calibration point editing, timed nd point, linear point to point, non-linear selectable auto-blank, low concentration range stability. mV Mode Range: ±2000.0. mV Mode Resolution: 0.1. mV Mode Relative Accuracy: ±0.2mV or ±0.05% of reading whichever is greater. mV Mode Calibration Points: 1. Temperature Mode Range: 23° to 221°F (-5° to 105°C). Temperature Mode Resolution: 0.1. Temperature Mode Relative Accuracy: ±0.1. Inputs: BNC, reference pin, 8-pin mini-DIN, stirrer port. Data Management: 2000 points with date/time stamp. Output: RS-232, USB. Display: Graphic LCD; simultaneous display of measurement, temperature, date/time, sample ID, user ID and more. Power Supply: Universal AC line voltage or optional four "AA" batteries. Environmental Operating Conditions Ambient Operating Temperature: 5 to 85% noncondensing. Thermo Scientific Orion #: STARA2147.

Documents & Videos

This Thermo Scientific Orion Star A214 pH/ISE/mV/Temperature Benchtop meter and Fluoride ISE kit is the ideal choice for any lab. The kit includes the 8102BNUWP ROSS Ultra Glass Refillable pH Electrode, a general purpose, top performance glass body combination electrode with waterproof BNC connector for precise pH determinations. The pH response is independent of temperature changes and can be used on any pH meter with a BNC connection. The kit also comes with the 927007MD stainless steel ATC probe (Mini-DIN connector; 1m cable) which automatically corrects pH measurements for variation in electrode slope due to temperature change, the 9609BNWP combination fluoride electrode which measure free fluoride ions in aqueous solutions quickly, simply, accurately and economically, and the 096019 automatic stirrer and paddle for use with Orion Star Meters and Orion 960 Titrator PLUS System which stirs samples for better accuracy and without having to deal with a separate stir plate and stir bar (fits Swing Arm Electrode Holder 96019). Kit also comes with the 040906 Fluoride 1ppm with TISAB II standard (475mL), the 040907 Fluoride 2ppm with TISAB II standard (475mL), the 040908 475mL Fluoride 10ppm with TISAB II standard (475mL), and the 940909 1-Gallon (3.8L) TISAB II for Fluoride electrode. The meter’s large, backlit graphic LCD display shows pH/mV/RmV/ISE results and temperature along with electrode status, time, date, sample ID, user ID and calibration points. For advanced users, features such as stability and averaging choices provide additional options. Anyone can use this meter with its plain language screen prompts, soft keys that update for easy selection and a multilanguage interface that supports English, Spanish, French, Italian, German and Chinese. The AUTO-READ™ locks in the stable reading on your screen, ready indicator alerts when readings are stable and timed reading gathers data in specific time intervals. Up to five point pH calibration with automatic recognition for USA/NIST and DIN buffers. Whether you use ISE infrequently or have multiple samples every day – up to five point ISE calibration with advanced features such as timed end point, linear point-to-point, non-linear selectable auto-blank and low-concentration range stability. Fix errors without a complete recalibration with the calibration editing function. The non-volatile memory holds up to 2000 data points with time and date stamp. Easily transfer data and keep meter software up-to-date with the USB and RS232 ports and complimentary data analysis software. Mix samples without a stir plate with direct control of the Orion Star stirrer probe (096019, sold separately). Included electrode arm and newly-designed probe holder make it easier to maintain and place probes into samples. Works with almost every AC power source with the included universal power adapter, or use four AA batteries (sold separately) to run the meter on DC power. IP54-rated housing handles splashes and is wall-mountable if table space is a problem. Three year meter replacement warranty. Certifications: CE, TUV, FCC Class A limits. pH Mode Range: -2.000 to 20.000. pH Mode Resolution: 0.1, 0.01, 0.001. pH Mode Relative Accuracy: ±0.002 pH Mode Calibration Points: up to 5. ISE Mode Range: 0 to 19999 in ppm, M, mg/L, %, ppb or unitless. ISE Mode Resolution: up to 3 significant digits. ISE Mode Relative Accuracy: ±0.2 mV or ±0.5% of reading, whichever is greater. ISE Mode Calibration Points: up to 5; Calibration point editing, timed nd point, linear point to point, non-linear selectable auto-blank, low concentration range stability. mV Mode Range: ±2000.0. mV Mode Resolution: 0.1. mV Mode Relative Accuracy: ±0.2mV or ±0.05% of reading whichever is greater. mV Mode Calibration Points: 1. Temperature Mode Range: 23° to 221°F (-5° to 105°C). Temperature Mode Resolution: 0.1. Temperature Mode Relative Accuracy: ±0.1. Inputs: BNC, reference pin, 8-pin mini-DIN, stirrer port. Data Management: 2000 points with date/time stamp. Output: RS-232, USB. Display: Graphic LCD; simultaneous display of measurement, temperature, date/time, sample ID, user ID and more. Power Supply: Universal AC line voltage or optional four "AA" batteries. Environmental Operating Conditions Ambient Operating Temperature: 5 to 85% noncondensing. Thermo Scientific Orion #: STARA2147.

Ratings & Reviews

No reviews available

Be the first to Write a Review