Thermo Scientific Orion VSTAR-CND VERSA STAR™ Conductivity Module For VERSA STAR™ Meters

  • VERSA STAR Conductivity/TDS/Resistivity/Salinity/Temperature Module easily connects into VERSA STAR meters
  • Conductivity/temperature module offers conductivity, TDS, salinity or resistivity capabilities and choice of practical salinity or natural sea water curves for salinity readings
  • Provides selectable reading reference temperatures of 5, 10, 15, 20 or 25 °C with linear, non-linear, nLFu or EP curve options for conductivity
  • No need to turn off your meter to switch modules –meter automatically recognizes module changes
  • Input: 8-pin mini-DIN
  • Sold individually
  • Manufacturer Part No: ORI-VSTAR-CND
(0) No Reviews yet

PLEASE NOTE: Product images and descriptions may not exactly represent the product. Prior to making your purchase, please confirm that the manufacturer part number shown above matches the product you seek. Returns are not allowed for such differences if the correct manufacturer part number is shipped.

Item Number: ORI-VSTAR-CND
$1,186.13

Sold in: Eaches

UnitMSRPYour PriceStock StatusQty
Each1,250.001,186.13Lead Time

New

Details

This Thermo Scientific Orion VERSA STAR Conductivity/TDS/Resistivity/Salinity/Temperature Module easily connects into VERSA STAR meters. The conductivity/temperature module offers conductivity, TDS, salinity or resistivity capabilities, selectable reading reference temperatures of 5, 10, 15, 20 or 25 °C with linear, non-linear, nLFu or EP curve options for conductivity, and choice of practical salinity or natural sea water curves for salinity readings. No need to turn off your meter to switch modules –meter automatically recognizes module changes. Conductivity—Range: 0.001?S to 3000mS. Resolution: 0.001?S minimum; 4 significant figures minimum: Relative Accuracy: 0.5 % reading ±1 digit. Reference Temperature: 5, 10, 15, 20, 25°C. Temperature Compensation: Linear (0 to 10.0 %/ºC), nLn, nLFu, EP. Compatible Cell Constants: 0.001 to 199.9. Calibration Points: Up to 6 points. Calibration Editing: Yes. Resistivity—Range: 2 ohm to 100 meg-ohm. Resolution: 2 ohms-cm. Relative Accuracy: 0.5 % reading ±1 digit. Salinity—Type: Practical salinity or natural sea water. Range: 0.01 to 80.0 ppt NaCl equivalent; 0.01 to 42 ppt practical salinity. Resolution: 0.01. Relative Accuracy: ±0.1. TDS—Range: 0 to 200 ppt. Resolution: 4 significant digits. Relative Accuracy: ±0.5 % reading ±1 digit. TDS Factor Range: Linear 0.01 to 10.00. Temperature—Range: -5 to 105 °C, 23 to 221 ºF. Resolution: 0.1. Relative Accuracy: ±0.1. Offset Calibration: 1 point. Input: 8-pin mini-DIN. Thermo Scientific Orion #: VSTAR-CND.

Documents & Videos

This Thermo Scientific Orion VERSA STAR Conductivity/TDS/Resistivity/Salinity/Temperature Module easily connects into VERSA STAR meters. The conductivity/temperature module offers conductivity, TDS, salinity or resistivity capabilities, selectable reading reference temperatures of 5, 10, 15, 20 or 25 °C with linear, non-linear, nLFu or EP curve options for conductivity, and choice of practical salinity or natural sea water curves for salinity readings. No need to turn off your meter to switch modules –meter automatically recognizes module changes. Conductivity—Range: 0.001?S to 3000mS. Resolution: 0.001?S minimum; 4 significant figures minimum: Relative Accuracy: 0.5 % reading ±1 digit. Reference Temperature: 5, 10, 15, 20, 25°C. Temperature Compensation: Linear (0 to 10.0 %/ºC), nLn, nLFu, EP. Compatible Cell Constants: 0.001 to 199.9. Calibration Points: Up to 6 points. Calibration Editing: Yes. Resistivity—Range: 2 ohm to 100 meg-ohm. Resolution: 2 ohms-cm. Relative Accuracy: 0.5 % reading ±1 digit. Salinity—Type: Practical salinity or natural sea water. Range: 0.01 to 80.0 ppt NaCl equivalent; 0.01 to 42 ppt practical salinity. Resolution: 0.01. Relative Accuracy: ±0.1. TDS—Range: 0 to 200 ppt. Resolution: 4 significant digits. Relative Accuracy: ±0.5 % reading ±1 digit. TDS Factor Range: Linear 0.01 to 10.00. Temperature—Range: -5 to 105 °C, 23 to 221 ºF. Resolution: 0.1. Relative Accuracy: ±0.1. Offset Calibration: 1 point. Input: 8-pin mini-DIN. Thermo Scientific Orion #: VSTAR-CND.

Ratings & Reviews

No reviews available

Be the first to Write a Review