UVP® 95-0438-01 UV3™ HEPA PCR Workstation with Four Stage Filter System & Three UV Light Sources, 254nm Shortwave, Inside W x D: 27.8 x 21.4-Inch, 115V

Item is discontinued. The manufacturer’s recommended alternate is item# 849-95-0600-01. Please find the alternate product link below in the related items section.
  • UV3 HEPA PCR workstation for eliminating PCR contamination, use a four-stage filter system
  • 32.5 H x 29 W x 24in D exterior; 27.8 W x 21.4in D interior; two 254nm shortwave 25-watt UV tubes (UV source - chamber); 115V; 60Hz; 9.1A
  • Features three UV sources, four stage filters, two power outlets, two small shelves, UV timer (< 30 min), antimicrobial coated Stainless Steel, Acrylic panels block below 400nm
  • Place large instruments on the work area or tubes, flasks and pipettes on the two removable shelves
  • Safety shut-off switch automatically turns the ultraviolet light off when the door is open
  • Sold individually
  • Manufacturer Part No: 95-0438-01
(0) No Reviews yet

PLEASE NOTE: Product images and descriptions may not exactly represent the product. Prior to making your purchase, please confirm that the manufacturer part number shown above matches the product you seek. Returns are not allowed for such differences if the correct manufacturer part number is shipped.

Item Number: UVP-95-0438-01
This item is discontinued. Please contact customer service at 512.836.1667 if you would like assistance finding an alternative item.

New

Details

This UV3 HEPA PCR workstationis designed for eliminating PCR contamination. This unit brings together UV irradiation and antimicrobial stainless steel to create a dual-attack environment against PCR contamination. HEPA/UV PCR systems additionally use a four-stage filter system - pre-filter captures large dust particles, Carbon filter (activated charcoal) eliminates gases, odor, smoke and also reduces Ozone to improve microarray data quality, HEPA (High Efficiency Energy Particulate) filter blocks particles down to 0.3 microns, ZerOzone catalyst grid not only blocks Ozone but it also supplies a gentle airflow onto the sample work area. This airflow creates a working environment that blocks entry of unwanted contaminants on PCR samples. Three UV (UV3) sources - filter area, chamber work area, UV/air recirculator. A 30 min timer sets shortwave UV exposure to decontaminate apparatus and work chamber for specific times. Antimicrobial coated stainless steel reduces bacterial growth. A safety shut-off switch automatically turns the ultraviolet light off when the door is open.

Place large instruments on the work area or tubes, flasks and pipettes on the two removable shelves. Built-in power outlets allow operation of equipment for use in PCR applications. Acrylic panels are specially formulated to block UV wavelengths below 400nm. Operational ratings - unit intended to be used indoors, altitude must not exceed 2000m, ambient temperature not to exceed 5 to 40°C (41 to 104°F), relative humidity not to exceed 80% for temperatures upto 31°C (88°F) decreasing linearly to 50% relative humidity at 40°C (104°F), main supply voltage fluctuations upto ±10% of the nominal voltage, pollution rating 2 or better for laboratory areas. Products come flat-packed for customer assembly. 32.5 H x 29 W x 24in D Exterior. 27.8 W x 21.4in D Interior. Two 254nm Shortwave 25-watt UV Tubes (UV Source - Chamber), One 254nm Shortwave 8-watt UV Tube (UV Air Circulator), Two White 8-watt Tubes (White Light) Light Source. 13 W x 4.2in D Shelves. Antimicrobial Coated stainless steel Shelves. Antimicrobial Coated stainless steel Interior. Aluminum Powder Coated Exterior. 115V. 60Hz. 9.1A. UVP® #: 95-0438-01.

Documents & Videos

This UV3 HEPA PCR workstationis designed for eliminating PCR contamination. This unit brings together UV irradiation and antimicrobial stainless steel to create a dual-attack environment against PCR contamination. HEPA/UV PCR systems additionally use a four-stage filter system - pre-filter captures large dust particles, Carbon filter (activated charcoal) eliminates gases, odor, smoke and also reduces Ozone to improve microarray data quality, HEPA (High Efficiency Energy Particulate) filter blocks particles down to 0.3 microns, ZerOzone catalyst grid not only blocks Ozone but it also supplies a gentle airflow onto the sample work area. This airflow creates a working environment that blocks entry of unwanted contaminants on PCR samples. Three UV (UV3) sources - filter area, chamber work area, UV/air recirculator. A 30 min timer sets shortwave UV exposure to decontaminate apparatus and work chamber for specific times. Antimicrobial coated stainless steel reduces bacterial growth. A safety shut-off switch automatically turns the ultraviolet light off when the door is open.

Place large instruments on the work area or tubes, flasks and pipettes on the two removable shelves. Built-in power outlets allow operation of equipment for use in PCR applications. Acrylic panels are specially formulated to block UV wavelengths below 400nm. Operational ratings - unit intended to be used indoors, altitude must not exceed 2000m, ambient temperature not to exceed 5 to 40°C (41 to 104°F), relative humidity not to exceed 80% for temperatures upto 31°C (88°F) decreasing linearly to 50% relative humidity at 40°C (104°F), main supply voltage fluctuations upto ±10% of the nominal voltage, pollution rating 2 or better for laboratory areas. Products come flat-packed for customer assembly. 32.5 H x 29 W x 24in D Exterior. 27.8 W x 21.4in D Interior. Two 254nm Shortwave 25-watt UV Tubes (UV Source - Chamber), One 254nm Shortwave 8-watt UV Tube (UV Air Circulator), Two White 8-watt Tubes (White Light) Light Source. 13 W x 4.2in D Shelves. Antimicrobial Coated stainless steel Shelves. Antimicrobial Coated stainless steel Interior. Aluminum Powder Coated Exterior. 115V. 60Hz. 9.1A. UVP® #: 95-0438-01.

Ratings & Reviews

No reviews available

Be the first to Write a Review