Eppendorf 940000807 Multiporator® Electroporator for Eukaryotic Cells, Bacteria, Yeasts & Cell Fusion with 1 Helix Fusion Chamber & 1 Micro Fusion Chamber

Item has been discontinued with no suggested replacement.
  • Eppendorf® Multiporator is made up of a module designed to electroporate eukaryotic cells, bacteria, yeasts and other microorganisms; includes one helix fusion chamber and one micro fusion chamber
  • For generation of tetraploid blastocysts, cloning of mammals, fusion of plant protoplasts, generation of hybridoma cells for the production of monoclonal antibodies, fusion of lipid vesicles
  • Programmable voltage and optimized, fixed pulse times, preadjusted voltages for the most frequent applications, and electronic safety circuit for arc prevention
  • Compact unit is easily portable, easy to disinfect, and easy to operate with user-friendly display; outstanding safety levels provided by the built-in cuvette chamber; CE-, UL- and CAS-approved
  • Features connectors for external electrodes, directly adjustable voltage and time constants, and Soft Pulse technology; two-year warranty
  • Sold individually
  • Manufacturer Part No: EP-940000807
(0) No Reviews yet

PLEASE NOTE: Product images and descriptions may not exactly represent the product. Prior to making your purchase, please confirm that the manufacturer part number shown above matches the product you seek. Returns are not allowed for such differences if the correct manufacturer part number is shipped.

Item Number: EPP-940000807
This item is discontinued. Please contact customer service at 512.836.1667 if you would like assistance finding an alternative item.

Details

The Eppendorf® Multiporator® basic unit is made up of a module designed to electroporate eukaryotic cells. This Eppendorf® Multiporator® includes one helix fusion chamber and one micro fusion chamber. It is used for electroporation of bacteria, yeasts and other microorganisms and cell fusion. The fusion module expands the Multiporator®’s capabilities with highly efficient electrical cell fusion. Cells are brought into contact with one another in an electrical alternating-current environment and then fused with a direct-current pulse. Optimize your cell fusion parameters using the Electrofusion Buffer System with only a few cells in the Micro fusion chamber. When using the 0.2mm Micro fusion chamber, the ideal parameters determined in this way can be directly transferred to the cell fusion in the Helix fusion chamber. Eppendorf® Multiporator® applications for the module for cell fusion include generation of tetraploid blastocysts, cloning of mammals, fusion of plant protoplasts, generation of hybridoma cells for the production of monoclonal antibodies, fusion of lipid vesicles. Special features include programmable voltage and optimized, fixed pulse times, preadjusted voltages for the most frequent applications, and electronic safety circuit for arc prevention. It also features a space-saving inner device module, definable alignment and pulse parameters, square wave pulse, optimized buffer system, and a micro fusion chamber for optimization. Use the Eppendorf® Multiporator® for the electroporation of animal and human cells, primary cells, plant cells and embryonic stem cells, stable and transient transfection of eukaryotic cells, and efficient and gentle transfer of siRNA. The Eppendorf® Multiporator® is compact unit is easily portable, easy to disinfect, and easy to operate with clear, user-friendly display. It has outstanding safety levels provided by the built-in cuvette chamber, and is CE-, UL- and CAS-approved. Features connectors for external electrodes, directly adjustable voltage and time constants, and Soft Pulse technology. Soft Pulse technology applies extremely short electric pulses for the highest survival rates. Cell-damaging influences, such as changes in pH values, aluminum release and electrophoresis of the cell content, are minimized. The relevant parameters of voltage and pulse duration are directly set, and the patented electronic pulse discharge ensures that they will be maintained exactly—independent of the sample resistance—for reliable and reproducible results. Patented microprocessor controlled pulse discharge (U.S. Pat. 6,008,038). Two-year warranty. Eppendorf® #: 940000807.

Documents & Videos

The Eppendorf® Multiporator® basic unit is made up of a module designed to electroporate eukaryotic cells. This Eppendorf® Multiporator® includes one helix fusion chamber and one micro fusion chamber. It is used for electroporation of bacteria, yeasts and other microorganisms and cell fusion. The fusion module expands the Multiporator®’s capabilities with highly efficient electrical cell fusion. Cells are brought into contact with one another in an electrical alternating-current environment and then fused with a direct-current pulse. Optimize your cell fusion parameters using the Electrofusion Buffer System with only a few cells in the Micro fusion chamber. When using the 0.2mm Micro fusion chamber, the ideal parameters determined in this way can be directly transferred to the cell fusion in the Helix fusion chamber. Eppendorf® Multiporator® applications for the module for cell fusion include generation of tetraploid blastocysts, cloning of mammals, fusion of plant protoplasts, generation of hybridoma cells for the production of monoclonal antibodies, fusion of lipid vesicles. Special features include programmable voltage and optimized, fixed pulse times, preadjusted voltages for the most frequent applications, and electronic safety circuit for arc prevention. It also features a space-saving inner device module, definable alignment and pulse parameters, square wave pulse, optimized buffer system, and a micro fusion chamber for optimization. Use the Eppendorf® Multiporator® for the electroporation of animal and human cells, primary cells, plant cells and embryonic stem cells, stable and transient transfection of eukaryotic cells, and efficient and gentle transfer of siRNA. The Eppendorf® Multiporator® is compact unit is easily portable, easy to disinfect, and easy to operate with clear, user-friendly display. It has outstanding safety levels provided by the built-in cuvette chamber, and is CE-, UL- and CAS-approved. Features connectors for external electrodes, directly adjustable voltage and time constants, and Soft Pulse technology. Soft Pulse technology applies extremely short electric pulses for the highest survival rates. Cell-damaging influences, such as changes in pH values, aluminum release and electrophoresis of the cell content, are minimized. The relevant parameters of voltage and pulse duration are directly set, and the patented electronic pulse discharge ensures that they will be maintained exactly—independent of the sample resistance—for reliable and reproducible results. Patented microprocessor controlled pulse discharge (U.S. Pat. 6,008,038). Two-year warranty. Eppendorf® #: 940000807.

Ratings & Reviews

No reviews available