H-B Instrument 5H-FC DURAC® API ASTM Certified Hydrometer, 330mm Length, API Range 39 to 51° with 0.1° Divisions and Calibration Points of 40°, 44° and 50°, ASTM Number 5H, NIST Traceable
Item Number:HB-5H-FC
Manufacturer Part No:61898-2200
Manufacturer:SP H-B Instrument
Units:Sold individually.
Details
- API Range: 39 to 51°
- API Scale Divisions: 0.1°
- Hydrometer Length: 330mm
- ASTM Number: 5H
- NIST Traceable Hydrometer
- Sold individually.
This DURAC® API hydrometer is designed specifically for use in determining the density of petroleum products according to the API (American Petroleum Institute) degree scale. These hydrometers are individually serialized and feature a metal ballast. Furnished complete with a detailed Calibration Report documenting corrections to one-tenth of the smallest division. API hydrometers are packaged in a fully recyclable, eco-friendly deluxe storage box. Includes multi-language (English, French, German, Italian, Portuguese and Spanish) Statement of Accuracy indicating accuracy traceable to NIST and DKD/PTB. Tested and calibrated in our exclusive triple accredited/registered ISO/IEC 17025:2005, A2LA accredited laboratory against equipment whose calibration is traceable to NIST and DKD/PTB. Temperature of Standardization 60°C/60°F. Length 330mm (13-Inch), Range: 39 to 51° on API Scale. Divisions: 0.1°, Accuracy: 0.1°. NIST Traceable. Factory Calibration Points at 40°, 44° and 50° of API Scale. ASTM Number: 5H. H-B Instrument Part Number: 5H-FC.
Documents & Videos
This DURAC® API hydrometer is designed specifically for use in determining the density of petroleum products according to the API (American Petroleum Institute) degree scale. These hydrometers are individually serialized and feature a metal ballast. Furnished complete with a detailed Calibration Report documenting corrections to one-tenth of the smallest division. API hydrometers are packaged in a fully recyclable, eco-friendly deluxe storage box. Includes multi-language (English, French, German, Italian, Portuguese and Spanish) Statement of Accuracy indicating accuracy traceable to NIST and DKD/PTB. Tested and calibrated in our exclusive triple accredited/registered ISO/IEC 17025:2005, A2LA accredited laboratory against equipment whose calibration is traceable to NIST and DKD/PTB. Temperature of Standardization 60°C/60°F. Length 330mm (13-Inch), Range: 39 to 51° on API Scale. Divisions: 0.1°, Accuracy: 0.1°. NIST Traceable. Factory Calibration Points at 40°, 44° and 50° of API Scale. ASTM Number: 5H. H-B Instrument Part Number: 5H-FC.