HANNA HI23211-1 Industrial Grade Wall-Mounted Conductivity Digital Controller with Four-Ring Potentiometric Probe, Dual Setpoint & On/Off Control, Output: Analog, Electrical: 115V

  • Manufacturer Part No: HI23211-1
(0) No Reviews yet

PLEASE NOTE: Product images and descriptions may not exactly represent the product. Prior to making your purchase, please confirm that the manufacturer part number shown above matches the product you seek. Returns are not allowed for such differences if the correct manufacturer part number is shipped.

Item Number: HAN-HI23211-1
This item is discontinued. Please contact customer service at 512.836.1667 if you would like assistance finding an alternative item.

New

Details

HI 2300 benchtop conductivity meter performs EC, TDS (Total Dissolved Solids), percentage of NaCl and temperature measurements. The auto-ranging feature for EC and TDS measurements automatically sets the resolution suitable to the tested sample. All measurements can be temperature compensated at 20 or 25°C and the compensation coefficient is selectable by the user. The automatic temperature compensation can also be disabled for measuring the actual conductivity value. The stability indicator on the LCD ensures accuracy. Conductivity readings are performed by applying an alternate current to the 4-ring probe which creates a variable voltage directly proportional to conductivity. The GLP feature allows users to store and recall data about system status. Hanna #: HI2300. • Range (EC): 0.00 to 29.99 µS/cm; 30.0 to 299.9 µS/cm; 300 to 2999 µS/cm; 3.00 to 29.99 mS/cm; 30.0 to 200.0 mS/cm; up to 500.0 mS/cm (actual EC).• Range (TDS): 0.00 to 14.99 mg/L (ppm); 15.0 to 149.9 mg/L (ppm); 150 to 1499 mg/L (ppm); 1.50 to 14.99 g/L (ppt); 15.0 to 100.0 g/L (ppt); up to 400.0 g/L (actual TDS), with 0.80 conversion factor.• Range (NaCl): 0.0 to 400.0% • Range (Temperature): -9.9 to 120.0°C • Resolution EC): 0.01 µS/cm; 0.1 µS/cm; 1 µS/cm; 0.01 mS/cm; 0.1 mS/cm • Resolution (TDS): 0.01 mg/L; 0.1 mg/L; 1 mg/L; 0.01 g/L; 0.1 g/L • Resolution (NaCl): 0.1% • Resolution (Temperature): 0.1°C • Accuracy EC ±1% of reading ±(0.05 µS/cm or 1 digit) • Accuracy (TDS): ±1% of reading ±(0.03 mg/L or 1 digit) • Accuracy (NaCl): ±1% of reading • Accuracy (Temperature): ±0.4°C • Calibration (EC): Automatic, 1 point with 6 memorized values (84, 1413, 5000, 12880, 80000, 111800 µS/cm) • Calibration (NaCl): 1 point, with HI 7037 calibration solution • Calibration (Temperature): 2 point, at 0 to 50°C (32 to 122°F) • Temperature Compensation: Automatic or manual, 0 to 60°C (32 to 140°F) • Temperature Coefficient: Selectable from 0.00 to 6.00%/°C (EC and TDS only) • TDS Conversion Factor: Selectable from 0.40 to 0.80 (default value 0.50) • Probe: HI 76310, 4-ring platinum, internal temperature sensor • Auto Shut-Off: After 5 minutes of non-use (can be disabled) • Power Supply: 12 Vdc adapter (included) • Environment: 0 to 50°C (32 to 122°F); RH max 95% • Dimensions: 240 x 182 x 74 mm (9.4 x 7.2 x 2.9") • Weight: 1.1 kg (2.4 lb.)

Documents & Videos

HI 2300 benchtop conductivity meter performs EC, TDS (Total Dissolved Solids), percentage of NaCl and temperature measurements. The auto-ranging feature for EC and TDS measurements automatically sets the resolution suitable to the tested sample. All measurements can be temperature compensated at 20 or 25°C and the compensation coefficient is selectable by the user. The automatic temperature compensation can also be disabled for measuring the actual conductivity value. The stability indicator on the LCD ensures accuracy. Conductivity readings are performed by applying an alternate current to the 4-ring probe which creates a variable voltage directly proportional to conductivity. The GLP feature allows users to store and recall data about system status. Hanna #: HI2300. • Range (EC): 0.00 to 29.99 µS/cm; 30.0 to 299.9 µS/cm; 300 to 2999 µS/cm; 3.00 to 29.99 mS/cm; 30.0 to 200.0 mS/cm; up to 500.0 mS/cm (actual EC).• Range (TDS): 0.00 to 14.99 mg/L (ppm); 15.0 to 149.9 mg/L (ppm); 150 to 1499 mg/L (ppm); 1.50 to 14.99 g/L (ppt); 15.0 to 100.0 g/L (ppt); up to 400.0 g/L (actual TDS), with 0.80 conversion factor.• Range (NaCl): 0.0 to 400.0% • Range (Temperature): -9.9 to 120.0°C • Resolution EC): 0.01 µS/cm; 0.1 µS/cm; 1 µS/cm; 0.01 mS/cm; 0.1 mS/cm • Resolution (TDS): 0.01 mg/L; 0.1 mg/L; 1 mg/L; 0.01 g/L; 0.1 g/L • Resolution (NaCl): 0.1% • Resolution (Temperature): 0.1°C • Accuracy EC ±1% of reading ±(0.05 µS/cm or 1 digit) • Accuracy (TDS): ±1% of reading ±(0.03 mg/L or 1 digit) • Accuracy (NaCl): ±1% of reading • Accuracy (Temperature): ±0.4°C • Calibration (EC): Automatic, 1 point with 6 memorized values (84, 1413, 5000, 12880, 80000, 111800 µS/cm) • Calibration (NaCl): 1 point, with HI 7037 calibration solution • Calibration (Temperature): 2 point, at 0 to 50°C (32 to 122°F) • Temperature Compensation: Automatic or manual, 0 to 60°C (32 to 140°F) • Temperature Coefficient: Selectable from 0.00 to 6.00%/°C (EC and TDS only) • TDS Conversion Factor: Selectable from 0.40 to 0.80 (default value 0.50) • Probe: HI 76310, 4-ring platinum, internal temperature sensor • Auto Shut-Off: After 5 minutes of non-use (can be disabled) • Power Supply: 12 Vdc adapter (included) • Environment: 0 to 50°C (32 to 122°F); RH max 95% • Dimensions: 240 x 182 x 74 mm (9.4 x 7.2 x 2.9") • Weight: 1.1 kg (2.4 lb.)

Ratings & Reviews

No reviews available

Be the first to Write a Review