• Home
  • HANNA HI8033 Portable Conductivity/TDS Meter, Conductivity Multirange: 0.0 to 199.9 Microsiemens/cm

HANNA HI8033 Portable Conductivity/TDS Meter, Conductivity Multirange: 0.0 to 199.9 Microsiemens/cm; 0 to 1999 Microsiemens/cm; 0 to 19990 Microsiemens/cm, TDS Range: 0 to 19990ppm

  • Manufacturer Part No: HI8033
(0) No Reviews yet

PLEASE NOTE: Product images and descriptions may not exactly represent the product. Prior to making your purchase, please confirm that the manufacturer part number shown above matches the product you seek. Returns are not allowed for such differences if the correct manufacturer part number is shipped.

Item Number: HAN-HI8033
This item is discontinued. Please contact customer service at 512.836.1667 if you would like assistance finding an alternative item.

Details

HI 8033 is a portable conductivity meter with the ability to take measurements in 3 different conductivity ranges, 0.0 to 199.9 µS/cm, 0 to 1999 µS/cm and 0.00 to 19.99 mS/cm and 1 TDS range: 0 to 19990 ppm CaCO3. The probe uses the 4-ring potentiometric method which measures conductivity with the utmost accuracy and reliability. The four stainless steel rings are embedded in the resin shaft of the probe to create a smooth surface for fast and easy cleaning. To improve accuracy, temperature compensation can be performed with a knob on the front panel of the meter. Hanna #: HI 8033. • Range (EC): 0.0 to 199.9 µS/cm; 0 to 1999 µS/cm; 0.00 to 19.99 mS/cm • Range (TDS): 0 to 19990 ppm • Resolution (EC): 0.1 µS/cm; 1 µS/cm; 0.01 mS/cm • Resolution (TDS): 10 ppm • Accuracy: ±1% F.S. (excluding probe error) • Calibration: Manual, 1 point • Temperature Compensation: Manual, 0 to 50°C (32 to 122°F) with ß=2%/°C • Probe: HI 76301W EC/TDS probe with 1 m (3.3') cable (included) • Battery Type / Life: 1 x 9V / Approx. 100 hours of continuous use • Environment: 0 to 50°C (32 to 122°F); RH max 95% • Dimensions: 185 x 82 x 47 mm (7.3 x 3.2 x 1.9") • Weight: 270 g (9.5 oz.)

Documents & Videos

HI 8033 is a portable conductivity meter with the ability to take measurements in 3 different conductivity ranges, 0.0 to 199.9 µS/cm, 0 to 1999 µS/cm and 0.00 to 19.99 mS/cm and 1 TDS range: 0 to 19990 ppm CaCO3. The probe uses the 4-ring potentiometric method which measures conductivity with the utmost accuracy and reliability. The four stainless steel rings are embedded in the resin shaft of the probe to create a smooth surface for fast and easy cleaning. To improve accuracy, temperature compensation can be performed with a knob on the front panel of the meter. Hanna #: HI 8033. • Range (EC): 0.0 to 199.9 µS/cm; 0 to 1999 µS/cm; 0.00 to 19.99 mS/cm • Range (TDS): 0 to 19990 ppm • Resolution (EC): 0.1 µS/cm; 1 µS/cm; 0.01 mS/cm • Resolution (TDS): 10 ppm • Accuracy: ±1% F.S. (excluding probe error) • Calibration: Manual, 1 point • Temperature Compensation: Manual, 0 to 50°C (32 to 122°F) with ß=2%/°C • Probe: HI 76301W EC/TDS probe with 1 m (3.3') cable (included) • Battery Type / Life: 1 x 9V / Approx. 100 hours of continuous use • Environment: 0 to 50°C (32 to 122°F); RH max 95% • Dimensions: 185 x 82 x 47 mm (7.3 x 3.2 x 1.9") • Weight: 270 g (9.5 oz.)

Ratings & Reviews

No reviews available

Be the first to Write a Review