HANNA HI83414-01 Benchtop Free & Total Chlorine/Turbidity Meter, EPA Compliant, Electrical: 115V

This item is 230V; please verify this is the correct voltage for your needs.
  • Manufacturer Part No: HI83414-01
(0) No Reviews yet

PLEASE NOTE: Product images and descriptions may not exactly represent the product. Prior to making your purchase, please confirm that the manufacturer part number shown above matches the product you seek. Returns are not allowed for such differences if the correct manufacturer part number is shipped.

Item Number: HAN-HI83414
$2,327.00

Sold in: Eaches

UnitMSRPYour PriceStock StatusQty
Each2,327.002,327.00Lead Time

New

Details

The HI 83414 combines turbidity and colorimetric measurements to meet the needs of measuring the most important parameters of drinking water: turbidity and free/total chlorine. This turbidity meter is designed for water quality measurements, providing readings on low turbidity and chlorine values. The HI 83414 meets and exceeds the requirements of USEPA and Standard Methods both for turbidity and colorimetric measurements.This turbidity meter guarantees accurate results and assures stability by minimizing stray light and color interferences. It also compensates for variations in intensity of the lamp, making no need for frequent calibration. The 525 nm intereference filter of the colorimeter assures precise and repeatable results. The 25 mm cuvets made from special optical glass guarantee the repeatability of measurements.Turbidity measurements can be made in the 0.00 to 4000 NTU (Nephelometric Turbidity Units) range when ratiometric measurements are used and in the 0.00 to 40.0 NTU range when non ratio method is used. The instrument has an EPA compliance reading mode which rounds the reading to meet EPA reporting requirements. Alternative EBC and Nephelos measuring units are available. A two, three, four or five-point calibration could be performed by using the supplied (<0.1, 15, 100, 750 and 2000 NTU) standards. When user prepared standards are used, the calibration points can be modified.As a chlorine meter the HANNA HI 83414 Free & Total Chlorine measurements can be made in the 0.00 to 5.00 mg/L (ppm) range. With the powerful CAL CHECK™ function, the good performance of the instrument can be validated at any moment by using the exclusive Hanna ready-made, NIST traceable standards. A one-point calibration can be performed using the same cal check standard. HI 83414 has complete G.L.P. (Good Laboratory Practice) functions that allows traceability of the calibration conditions. The last calibration points, time and date can be checked.The HI 83414 turbidity meter has a user-friendly interface with an easy to understand, graphical LCD. All messages are in plain text, easy to read and understand. Contextual help is available at a simple key press. Confirmation and error acoustic signals help the user during instrument operation. Furthermore, a tutorial mode guides the user, step by step, through the analysis process. The logging function offers complete information for the measurement. Up to 200 measurements can be stored in memory and consulted at any time. The data can be downloaded to a PC using the USB port. 115V. (230V model available - See Item #: HAN-HI83414-02) Hanna #: HI 83414-01. Range (Non Ratio Mode): 0.00 to 9.99; 10.0 to 40.0 NTU; / 0.0 to 99.9; 100 to 268 Nephelos; / 0.00 to 9.80 EBC Resolution (Non Ratio Mode): 0.01; 0.1 NTU; / 0.1; 1 Nephelos / 0.01 EBC Range (Ratio Mode): 0.00 to 9.99; 10.0 to 99.9; 100 to 4000 NTU / 0.0 to 99.9; 100 to 26800 Nephelos / 0.00 to 9.99; 10.0 to 99.9; 100 to 980 EBC Resolution (Ratio Mode): 0.01; 0.1; 1 NTU / 0.1; 1 Nephelos / 0.01; 0.1, 1 EBC Range Selection: Automatically Accuracy: ±1% of reading or 0.02 NTU (0.15 Nephelos; 0.01 EBC) / ±2% of reading plus 0.02 NTU (0.15 Nephelos; 0.01 EBC) ±5% of reading above 1000 NTU (6700 Nephelos; 245 EBC) Repeatibility: ±1% of reading or 0.02 NTU (0.15 Nephelos; 0.01 EBC) whichever is greater Stray Light: < 0.02 NTU (0.15 Nephelos; 0.01 EBC) Light Detection: Silicon Photocell Method: Nephelometric method (90°) or Ratio Nephelometric Method (90° & 180°), Adaptation of the USEPA Method 108.1 and Standard Method 2130 B. Measuring Mode: Normal, Average, Continuous. Turbidity Standards: <0.1, 15, 100, 750 and 2000 NTUCalibration: Two, three, four or five-point calibration Range (Free Chlorine): 0.00 to 5.00 mg/L Range (Total Chlorine): 0.00 to 5.00 mg/L

Documents & Videos

The HI 83414 combines turbidity and colorimetric measurements to meet the needs of measuring the most important parameters of drinking water: turbidity and free/total chlorine. This turbidity meter is designed for water quality measurements, providing readings on low turbidity and chlorine values. The HI 83414 meets and exceeds the requirements of USEPA and Standard Methods both for turbidity and colorimetric measurements.This turbidity meter guarantees accurate results and assures stability by minimizing stray light and color interferences. It also compensates for variations in intensity of the lamp, making no need for frequent calibration. The 525 nm intereference filter of the colorimeter assures precise and repeatable results. The 25 mm cuvets made from special optical glass guarantee the repeatability of measurements.Turbidity measurements can be made in the 0.00 to 4000 NTU (Nephelometric Turbidity Units) range when ratiometric measurements are used and in the 0.00 to 40.0 NTU range when non ratio method is used. The instrument has an EPA compliance reading mode which rounds the reading to meet EPA reporting requirements. Alternative EBC and Nephelos measuring units are available. A two, three, four or five-point calibration could be performed by using the supplied (<0.1, 15, 100, 750 and 2000 NTU) standards. When user prepared standards are used, the calibration points can be modified.As a chlorine meter the HANNA HI 83414 Free & Total Chlorine measurements can be made in the 0.00 to 5.00 mg/L (ppm) range. With the powerful CAL CHECK™ function, the good performance of the instrument can be validated at any moment by using the exclusive Hanna ready-made, NIST traceable standards. A one-point calibration can be performed using the same cal check standard. HI 83414 has complete G.L.P. (Good Laboratory Practice) functions that allows traceability of the calibration conditions. The last calibration points, time and date can be checked.The HI 83414 turbidity meter has a user-friendly interface with an easy to understand, graphical LCD. All messages are in plain text, easy to read and understand. Contextual help is available at a simple key press. Confirmation and error acoustic signals help the user during instrument operation. Furthermore, a tutorial mode guides the user, step by step, through the analysis process. The logging function offers complete information for the measurement. Up to 200 measurements can be stored in memory and consulted at any time. The data can be downloaded to a PC using the USB port. 115V. (230V model available - See Item #: HAN-HI83414-02) Hanna #: HI 83414-01. Range (Non Ratio Mode): 0.00 to 9.99; 10.0 to 40.0 NTU; / 0.0 to 99.9; 100 to 268 Nephelos; / 0.00 to 9.80 EBC Resolution (Non Ratio Mode): 0.01; 0.1 NTU; / 0.1; 1 Nephelos / 0.01 EBC Range (Ratio Mode): 0.00 to 9.99; 10.0 to 99.9; 100 to 4000 NTU / 0.0 to 99.9; 100 to 26800 Nephelos / 0.00 to 9.99; 10.0 to 99.9; 100 to 980 EBC Resolution (Ratio Mode): 0.01; 0.1; 1 NTU / 0.1; 1 Nephelos / 0.01; 0.1, 1 EBC Range Selection: Automatically Accuracy: ±1% of reading or 0.02 NTU (0.15 Nephelos; 0.01 EBC) / ±2% of reading plus 0.02 NTU (0.15 Nephelos; 0.01 EBC) ±5% of reading above 1000 NTU (6700 Nephelos; 245 EBC) Repeatibility: ±1% of reading or 0.02 NTU (0.15 Nephelos; 0.01 EBC) whichever is greater Stray Light: < 0.02 NTU (0.15 Nephelos; 0.01 EBC) Light Detection: Silicon Photocell Method: Nephelometric method (90°) or Ratio Nephelometric Method (90° & 180°), Adaptation of the USEPA Method 108.1 and Standard Method 2130 B. Measuring Mode: Normal, Average, Continuous. Turbidity Standards: <0.1, 15, 100, 750 and 2000 NTUCalibration: Two, three, four or five-point calibration Range (Free Chlorine): 0.00 to 5.00 mg/L Range (Total Chlorine): 0.00 to 5.00 mg/L

Ratings & Reviews

No reviews available

Be the first to Write a Review