• HANNA HI9126 Calibration Check™ Portable pH/ORP/Temperature Meter, pH Range: pH -2.00 to 16.00, ORP

HANNA HI9126 Calibration Check™ Portable pH/ORP/Temperature Meter, pH Range: pH -2.00 to 16.00, ORP Dual Range: ±699.9mV/±1999mV, Temperature Dual Range: -20.0 to 120.0°C/-4.0 to 248.0°F

Item Number:HAN-HI9126
Manufacturer Part No:HI9126
Manufacturer:Hanna Instruments
Units:Sold individually

Details

  • Calibration Check™ monitors the pH bulb and reference junction of the electrode every time the instrument is calibrated
  • Warns users when maintenance may be needed in the case of a dirty pH electrode
  • Stores and recalls readings at the touch of a button
  • Double junction helps to minimize junction contamination for consistently accurate results
  • Can also measure ORP using optional probes
  • Sold individually
The HI 9126 includes HANNA‘s exclusive Calibration Check™ technology. Calibration Check™ monitors the pH bulb and reference junction of the electrode every time the instrument is calibrated. In the event of a dirty pH electrode, Calibration Check™ warns users that maintenance may be needed. Calibrated buffers are continuously displayed in measurement mode to remind users of the instrument’s calibration point. Users can easily determine if readings are taken too far outside the calibration range. The HI 9126 can store and recall readings at the touch of a button. HI 9126 utilizes the HI 1230B double junction pH electrode. The double junction helps to minimize junction contamination for consistently accurate results. The HI 9126 can also measure ORP using optional probes. HI 9126 is supplied with HI 1230B pH electrode, HI 7662 temperature probe, HI 70004 pH 4.01 buffer solution sachet, HI 70007 pH 7.01 buffer sachet, HI 700661 electrode cleaning solution sachet, 100 mL plastic beaker, batteries, instructions and hard carrying case. pH Range: pH -2.00 to 16.00. ORP Dual Range: ±699.9mV/±1999mV. Temperature Dual Range: -20.0 to 120.0°C/-4.0 to 248.0°F. HANNA #: HI9126.

Documents & Videos

The HI 9126 includes HANNA‘s exclusive Calibration Check™ technology. Calibration Check™ monitors the pH bulb and reference junction of the electrode every time the instrument is calibrated. In the event of a dirty pH electrode, Calibration Check™ warns users that maintenance may be needed. Calibrated buffers are continuously displayed in measurement mode to remind users of the instrument’s calibration point. Users can easily determine if readings are taken too far outside the calibration range. The HI 9126 can store and recall readings at the touch of a button. HI 9126 utilizes the HI 1230B double junction pH electrode. The double junction helps to minimize junction contamination for consistently accurate results. The HI 9126 can also measure ORP using optional probes. HI 9126 is supplied with HI 1230B pH electrode, HI 7662 temperature probe, HI 70004 pH 4.01 buffer solution sachet, HI 70007 pH 7.01 buffer sachet, HI 700661 electrode cleaning solution sachet, 100 mL plastic beaker, batteries, instructions and hard carrying case. pH Range: pH -2.00 to 16.00. ORP Dual Range: ±699.9mV/±1999mV. Temperature Dual Range: -20.0 to 120.0°C/-4.0 to 248.0°F. HANNA #: HI9126.