HANNA HI93552R Portable Waterproof Dual-Channel K/J/T-Type Thermocouple Thermometer with PC Connectivity, Multi-Range: -200.0 to 999.9°C/1000 to 1371°C/-328.0 to 999.9°F/1000 to 2500°F

  • Manufacturer Part No: HI93552R
(0) No Reviews yet

PLEASE NOTE: Product images and descriptions may not exactly represent the product. Prior to making your purchase, please confirm that the manufacturer part number shown above matches the product you seek. Returns are not allowed for such differences if the correct manufacturer part number is shipped.

Item Number: T3452H-2
This item is discontinued. Please contact customer service at 512.836.1667 if you would like assistance finding an alternative item.

Details

When it's necessary to take temperature measurements with different types of thermocouples, HANNA® makes it possible in a single meter! For this purpose, Hanna Instruments has developed the HI 93552R dual-channel, waterproof K, J and T-type thermocouple thermometer. These professional grade thermocouple thermometers will switch between thermocouple types and linearize the readings taken with each.These thermocouple thermometers offer a resolution of 0.1° from -149.9 to 999.9°C and from -24.9 to 999.9°F with a HOLD button to freeze the display for easy recording. At any time, you can switch views to see all, continuously updated information, on either channel. Current temperature can be shown along with the high, low or average values. The current or average differences between channels is displayed with the temperature at both probes or the high/low of the difference. In addition, the HI 93552R model allows users to send the displayed measurement to a PC or printer through an RS232 serial port (once every 2 seconds). Finally, you can set a relative temperature at each channel and then see the variance from that reference point. Hanna #: HI 93552R. Range (K-Type): -200.0 to 999.9°C; 1000 to 1371°C; -328.0 to 999.9°F; 1000 to 2500°F Range (J-Type): -200.0 to 999.9°C; -328.0 to 999.9°F; 1000 to 1832°FRange (Temperature): -200.0 to 400.0°C; -328.0 to 752.0°F Resolution (K-Type): 0.1°C (-149.9 to 999.9°C); 0.2°C (-200.0 to -150.0°C); 1°C (1000 to 1371°C) / 0.1°F (-24.9 to 999.9°F); 0.2°F (-249.9 to -25.0°F) / 0.3°F (-328.0 to 250.0°F); 1°F (1000 to 2500°F)Resolution (J-Type): 0.1°C (-200.0 to 999.9°C) / 0.1°F (-149.9 to 999.9°F) / 0.2°F (-328.0 to 150.0°F); 1°F (1000 to 1832°F) Resolution (Temperature): 0.1°C (-149.9 to 999.9°C); 0.2°C (-200.0 to -150.0°C) / 0.1°F (0.0 to 752.0°F); 0.2°F (-270.0 to -0.1°F); 0.3°F (-328.0 to -270.1°F) Accuracy: ±0.5°C (-100.0 to 999.9°C); ±1°C (outside); ±1°F (-148.0 to 999.9°F); ±1.5° (outside); (for 1 year, excluding probe error) Probe: K-thermocouple type, HI 766 series (not included) Battery Type / Life: 3 x 1.5V AA / approx. 500 hours of continuous use (with backlight off); Auto-Off after 60 minutes of non-use (can be disabled).Environment: -10 to 50°C (14 to 122°F); RH max 100% Dimensions: 150 x 80 x 36 mm (5.9 x 3.1 x 1.4") Weight: 235 g (8.3 oz.) HI 93552R is supplied with batteries, protective case and instructions.

Documents & Videos

When it's necessary to take temperature measurements with different types of thermocouples, HANNA® makes it possible in a single meter! For this purpose, Hanna Instruments has developed the HI 93552R dual-channel, waterproof K, J and T-type thermocouple thermometer. These professional grade thermocouple thermometers will switch between thermocouple types and linearize the readings taken with each.These thermocouple thermometers offer a resolution of 0.1° from -149.9 to 999.9°C and from -24.9 to 999.9°F with a HOLD button to freeze the display for easy recording. At any time, you can switch views to see all, continuously updated information, on either channel. Current temperature can be shown along with the high, low or average values. The current or average differences between channels is displayed with the temperature at both probes or the high/low of the difference. In addition, the HI 93552R model allows users to send the displayed measurement to a PC or printer through an RS232 serial port (once every 2 seconds). Finally, you can set a relative temperature at each channel and then see the variance from that reference point. Hanna #: HI 93552R. Range (K-Type): -200.0 to 999.9°C; 1000 to 1371°C; -328.0 to 999.9°F; 1000 to 2500°F Range (J-Type): -200.0 to 999.9°C; -328.0 to 999.9°F; 1000 to 1832°FRange (Temperature): -200.0 to 400.0°C; -328.0 to 752.0°F Resolution (K-Type): 0.1°C (-149.9 to 999.9°C); 0.2°C (-200.0 to -150.0°C); 1°C (1000 to 1371°C) / 0.1°F (-24.9 to 999.9°F); 0.2°F (-249.9 to -25.0°F) / 0.3°F (-328.0 to 250.0°F); 1°F (1000 to 2500°F)Resolution (J-Type): 0.1°C (-200.0 to 999.9°C) / 0.1°F (-149.9 to 999.9°F) / 0.2°F (-328.0 to 150.0°F); 1°F (1000 to 1832°F) Resolution (Temperature): 0.1°C (-149.9 to 999.9°C); 0.2°C (-200.0 to -150.0°C) / 0.1°F (0.0 to 752.0°F); 0.2°F (-270.0 to -0.1°F); 0.3°F (-328.0 to -270.1°F) Accuracy: ±0.5°C (-100.0 to 999.9°C); ±1°C (outside); ±1°F (-148.0 to 999.9°F); ±1.5° (outside); (for 1 year, excluding probe error) Probe: K-thermocouple type, HI 766 series (not included) Battery Type / Life: 3 x 1.5V AA / approx. 500 hours of continuous use (with backlight off); Auto-Off after 60 minutes of non-use (can be disabled).Environment: -10 to 50°C (14 to 122°F); RH max 100% Dimensions: 150 x 80 x 36 mm (5.9 x 3.1 x 1.4") Weight: 235 g (8.3 oz.) HI 93552R is supplied with batteries, protective case and instructions.

Ratings & Reviews

No reviews available

Be the first to Write a Review