HANNA HI96734C Portable Free & Total Chlorine Photometer with Cal Check™, Rigid Carrying Case & Accessories (High Range), Range: 0.00 to 10.00ppm

Item has been discontinued with no suggested replacement
  • Photometer kit includes HI96734 photometer, rigid carrying case, 2 sample cuvettes with caps, scissors, cuvette cleaning cloth, 9V battery, instrument quality certificate, and instruction manual
  • Measures the free and total chlorine content in water samples in the 0.00 to 10.00 mg/L (ppm) range using liquid or powder reagents
  • Powered by a 9V battery, with a tungsten lamp light source and a silicon photocell with narrow band interference filter at 525nm for light detection
  • Features an auto-off after ten minutes of non-use in measurement mode and after one hour of non-use in calibration mode with a last reading reminder
  • Use in a temperature enviroment of 0 to 50°C (32 to 122°F), with a maximum non-condensing relative humidiy of 95%
  • Sold individually
  • Manufacturer Part No: HI96734C
(0) No Reviews yet

PLEASE NOTE: Product images and descriptions may not exactly represent the product. Prior to making your purchase, please confirm that the manufacturer part number shown above matches the product you seek. Returns are not allowed for such differences if the correct manufacturer part number is shipped.

Item Number: W3956-1H2WC
This item is discontinued. Please contact customer service at 512.836.1667 if you would like assistance finding an alternative item.

New

Details

Responding to the user's requirements for analyzing high concentrations of chlorine, HANNA® offers the HI 96734 portable digital photometer, which permits free and total chlorine analysis up to 10.00 mg/mL. This auto-diagnostic portable photometer is dedicated to monitoring over-chlorination through to chlorinamine destruction. The advanced optical system employs a specialized tungsten lamp and a narrow band interference filter, assuring accurate readings. This instrument is equipped with Cal Check® validation function and standards to validate good performance at any time. Taking just a few short steps, the validation procedure is user-friendly and ensures that the meter is properly calibrated wherever you go. Hanna photometers use the exclusive ready-made, NiST traceable standards to verify the performance of the instrument and recalibrate if necessary. Cuvets are constructed from specialized optical glass to ensure the best and most consistent results. The positive locking system ensures that the cuvet is in the same position every time it is placed into the measuring cell. Our sample cell is designed to fit a cuvet with a wide neck to make it easier to add both sample and reagents. All instruments are factory calibrated and the electronic and optical design minimizes the need for frequent calibration. Ideal for field applications, these meters are splash proof and the lamp and filter units are protected from dust or dirt by a transparent barrier. Display messages aid the user during routine operation. The auto-off feature will disengage the meter after 10 minutes of non-use in measuring mode or 1 hour while in calibration mode. The HI 96734 waterproof photometer utilizes an adaptation of the USEPA Method 330.5 and Standard Method 4500-Cl. The reaction between free and total chlorine and DPD reagent causes a pink tint in the sample. Hanna #: HI 96734C. Range (Free Chlorine): 0.00 to 10.00 mg/L Range (Total Chlorine): 0.00 to 10.00 mg/L Accuracy: ±0.06 mg/L to 3.00 mg/L Light Source: Tungsten lamp with narrow band interface filter 525 nm Light Detection: Silicon Photocell Power Supply: 1 x 9V battery Auto Shut-Off: After 10 minutes of non-use in measurement mode. / After 1 hour of non-use in calibration mode Environment: 0 to 50°C (32 to 122°F); RH max 95% non-condensing Dimensions: 180 x 83 x 46 mm (7.1 x 3.3 x 1.8") Weight: 290 g (10 oz.) Method Standard Methods 4500-Cl G / Adaptation of USEPA 330.5 method. The reaction between free chlorine and the DPD reagent causes a pink tint in the sample. HI 96734 is supplied with (2) sample cuvets with caps, 9V battery and instruction manual.

Documents & Videos

Responding to the user's requirements for analyzing high concentrations of chlorine, HANNA® offers the HI 96734 portable digital photometer, which permits free and total chlorine analysis up to 10.00 mg/mL. This auto-diagnostic portable photometer is dedicated to monitoring over-chlorination through to chlorinamine destruction. The advanced optical system employs a specialized tungsten lamp and a narrow band interference filter, assuring accurate readings. This instrument is equipped with Cal Check® validation function and standards to validate good performance at any time. Taking just a few short steps, the validation procedure is user-friendly and ensures that the meter is properly calibrated wherever you go. Hanna photometers use the exclusive ready-made, NiST traceable standards to verify the performance of the instrument and recalibrate if necessary. Cuvets are constructed from specialized optical glass to ensure the best and most consistent results. The positive locking system ensures that the cuvet is in the same position every time it is placed into the measuring cell. Our sample cell is designed to fit a cuvet with a wide neck to make it easier to add both sample and reagents. All instruments are factory calibrated and the electronic and optical design minimizes the need for frequent calibration. Ideal for field applications, these meters are splash proof and the lamp and filter units are protected from dust or dirt by a transparent barrier. Display messages aid the user during routine operation. The auto-off feature will disengage the meter after 10 minutes of non-use in measuring mode or 1 hour while in calibration mode. The HI 96734 waterproof photometer utilizes an adaptation of the USEPA Method 330.5 and Standard Method 4500-Cl. The reaction between free and total chlorine and DPD reagent causes a pink tint in the sample. Hanna #: HI 96734C. Range (Free Chlorine): 0.00 to 10.00 mg/L Range (Total Chlorine): 0.00 to 10.00 mg/L Accuracy: ±0.06 mg/L to 3.00 mg/L Light Source: Tungsten lamp with narrow band interface filter 525 nm Light Detection: Silicon Photocell Power Supply: 1 x 9V battery Auto Shut-Off: After 10 minutes of non-use in measurement mode. / After 1 hour of non-use in calibration mode Environment: 0 to 50°C (32 to 122°F); RH max 95% non-condensing Dimensions: 180 x 83 x 46 mm (7.1 x 3.3 x 1.8") Weight: 290 g (10 oz.) Method Standard Methods 4500-Cl G / Adaptation of USEPA 330.5 method. The reaction between free chlorine and the DPD reagent causes a pink tint in the sample. HI 96734 is supplied with (2) sample cuvets with caps, 9V battery and instruction manual.