HANNA HI96761C Portable Total Chlorine Photometer with Cal Check™, Rigid Carrying Case & Accessories (Low Range), for use with Powder Reagent, Range: 0.000 to 0.500ppm, Resolution: 0.001ppm

Item has been discontinued with no suggested replacement
  • Photometer kit includes HI96761 photometer, rigid carrying case, 2 sample cuvettes with caps, scissors, cuvette cleaning cloth, 9V battery, instrument quality certificate, and instruction manual
  • Measures low range total chlorine content in water samples in the 0.000 to 0.500 mg/L (ppm) range using powder reagents
  • Powered by a 9V battery, with a tungsten lamp light source and a silicon photocell with narrow band interference filter at 525nm for light detection
  • Features an auto-off after ten minutes of non-use in measurement mode and after one hour of non-use in calibration mode with a last reading reminder
  • Use in a temperature enviroment of 0 to 50°C (32 to 122°F), with a maximum non-condensing relative humidiy of 95%
  • Sold individually
  • Manufacturer Part No: HI96761C
(0) No Reviews yet

PLEASE NOTE: Product images and descriptions may not exactly represent the product. Prior to making your purchase, please confirm that the manufacturer part number shown above matches the product you seek. Returns are not allowed for such differences if the correct manufacturer part number is shipped.

Item Number: W3956-1WTC
This item is discontinued. Please contact customer service at 512.836.1667 if you would like assistance finding an alternative item.

New

Details

Total chlorine is given by the sum of free chlorine plus combined chlorine, where free chlorine combines with nitrogen to produce chloramines. Chloramines is harmful to aquatic life and damages water treatment plants that use membranes for water purification (e.g. reverse osmosis). Chloramines concentration in water depends on pH, temperature, the initial ratio of chlorine and amines, chlorine demand and total time of exposure. Both forms of chlorine (free and combined) can exist at the same time, though they need to be measured separately. HI 96761C is an auto-diagnostic portable photometer for accurately measuring trace total chlorine for ion-exchange membranes and resins. The advanced optical system employs a specialized tungsten lamp and a narrow band interference filter, assuring accurate readings between 0.000 to 0.500 mg/L. This instrument is equipped with Cal Check® validation function and standards to validate good performance at any time. Taking just a few short steps, the validation procedure is user-friendly and ensures that the meter is properly calibrated wherever you go. Hanna photometers use the exclusive ready-made, NiST traceable standards to verify the performance of the instrument and recalibrate if necessary. Cuvets are constructed from specialized optical glass to ensure the best and most consistent results. The positive locking system ensures that the cuvet is in the same position every time it is placed into the measuring cell. Our sample cell is designed to fit a cuvet with a wide neck to make it easier to add both sample and reagents. All instruments are factory calibrated and the electronic and optical design minimizes the need for frequent calibration. Ideal for field applications, these meters are splash proof and the lamp and filter units are protected from dust or dirt by a transparent barrier. Display messages aid the user during routine operation. The auto-off feature will disengage the meter after 10 minutes of non-use in measuring mode or 1 hour while in calibration mode. HI 96761 utilizes an adaptation of the Standard Methods, 20th Edition, 4500-Cl G. The reaction between chlorine and DPD causes a pink tint in the sample. Hanna #: HI 96761C. Range (Total Chlorine): 0.000 to 0.500 mg/L Light Source: Tungsten lamp with narrow band interface filter 525 nm Light Detection: Silicon Photocell Power Supply: 1 x 9V battery Auto Shut-Off: After 10 minutes of non-use in measurement mode. / After 1 hour of non-use in calibration mode Environment: 0 to 50°C (32 to 122°F); RH max 95% non-condensing Dimensions: 180 x 83 x 46 mm (7.1 x 3.3 x 1.8") Weight: 290 g (10 oz.) Method: Adaptation of Standard Methods, 20th edition, 4500-Cl G. The reaction between chlorine and the DPD reagent causes a pink tint in the sample. HI 96761C is supplied with CAL CHECK™ standard cuvets, (2) sample cuvets with caps, 9V battery, tissue for wiping cuvets, scissors and instruction manual in a hard carrying case.

Documents & Videos

Total chlorine is given by the sum of free chlorine plus combined chlorine, where free chlorine combines with nitrogen to produce chloramines. Chloramines is harmful to aquatic life and damages water treatment plants that use membranes for water purification (e.g. reverse osmosis). Chloramines concentration in water depends on pH, temperature, the initial ratio of chlorine and amines, chlorine demand and total time of exposure. Both forms of chlorine (free and combined) can exist at the same time, though they need to be measured separately. HI 96761C is an auto-diagnostic portable photometer for accurately measuring trace total chlorine for ion-exchange membranes and resins. The advanced optical system employs a specialized tungsten lamp and a narrow band interference filter, assuring accurate readings between 0.000 to 0.500 mg/L. This instrument is equipped with Cal Check® validation function and standards to validate good performance at any time. Taking just a few short steps, the validation procedure is user-friendly and ensures that the meter is properly calibrated wherever you go. Hanna photometers use the exclusive ready-made, NiST traceable standards to verify the performance of the instrument and recalibrate if necessary. Cuvets are constructed from specialized optical glass to ensure the best and most consistent results. The positive locking system ensures that the cuvet is in the same position every time it is placed into the measuring cell. Our sample cell is designed to fit a cuvet with a wide neck to make it easier to add both sample and reagents. All instruments are factory calibrated and the electronic and optical design minimizes the need for frequent calibration. Ideal for field applications, these meters are splash proof and the lamp and filter units are protected from dust or dirt by a transparent barrier. Display messages aid the user during routine operation. The auto-off feature will disengage the meter after 10 minutes of non-use in measuring mode or 1 hour while in calibration mode. HI 96761 utilizes an adaptation of the Standard Methods, 20th Edition, 4500-Cl G. The reaction between chlorine and DPD causes a pink tint in the sample. Hanna #: HI 96761C. Range (Total Chlorine): 0.000 to 0.500 mg/L Light Source: Tungsten lamp with narrow band interface filter 525 nm Light Detection: Silicon Photocell Power Supply: 1 x 9V battery Auto Shut-Off: After 10 minutes of non-use in measurement mode. / After 1 hour of non-use in calibration mode Environment: 0 to 50°C (32 to 122°F); RH max 95% non-condensing Dimensions: 180 x 83 x 46 mm (7.1 x 3.3 x 1.8") Weight: 290 g (10 oz.) Method: Adaptation of Standard Methods, 20th edition, 4500-Cl G. The reaction between chlorine and the DPD reagent causes a pink tint in the sample. HI 96761C is supplied with CAL CHECK™ standard cuvets, (2) sample cuvets with caps, 9V battery, tissue for wiping cuvets, scissors and instruction manual in a hard carrying case.