HANNA HI96771C Portable Free Chlorine Photometer with Cal Check™, Rigid Carrying Case & Accessories (Ultra-High Range), for use with Powder Reagent, Free Chlorine Range: 0.00 to 5.00ppm, Chlorine Ultra-High Range: 0 to 500ppm

Item has been discontinued with no suggested replacement
  • Photometer kit includes HI96771 photometer, rigid carrying case, 2 sample cuvettes with caps, scissors, cuvette cleaning cloth, 9V battery, instrument quality certificate, and instruction manual
  • Measures free chlorine in the 0.000 to 0.500 mg/L (ppm) range and ultra high chlorine in the 0 to 500mg/L range using powder reagents; checks chlorine dosing in food industry disinfection processes
  • Powered by a 9V battery, with a tungsten lamp light source and a silicon photocell with narrow band interference filter at 525nm for light detection
  • Features an auto-off after ten minutes of non-use in measurement mode and after one hour of non-use in calibration mode with a last reading reminder
  • Use in a temperature enviroment of 0 to 50°C (32 to 122°F), with a maximum non-condensing relative humidiy of 95%
  • Sold individually
  • Manufacturer Part No: HI96771C
(0) No Reviews yet

PLEASE NOTE: Product images and descriptions may not exactly represent the product. Prior to making your purchase, please confirm that the manufacturer part number shown above matches the product you seek. Returns are not allowed for such differences if the correct manufacturer part number is shipped.

Item Number: W3956-1H1WC
This item is discontinued. Please contact customer service at 512.836.1667 if you would like assistance finding an alternative item.

New

Details

Responding to the user's requirements for analyzing high concentrations of chlorine, HANNA® offers HI 96771C, an auto-diagnostic portable photometer which measures free chlorine from 0 to 5.00 and 0 to 500 mg/L range. The advanced optical system employs a specialized tungsten lamp and a narrow band interference filter, assuring accurate readings. This instrument is equipped with Cal Check® validation function and standards to validate good performance at any time. Taking just a few short steps, the validation procedure is user-friendly and ensures that the meter is properly calibrated wherever you go. Hanna photometers use the exclusive ready-made, NiST traceable standards to verify the performance of the instrument and recalibrate if necessary. Cuvets are constructed from specialized optical glass to ensure the best and most consistent results. The positive locking system ensures that the cuvet is in the same position every time it is placed into the measuring cell. Our sample cell is designed to fit a cuvet with a wide neck to make it easier to add both sample and reagents. All instruments are factory calibrated and the electronic and optical design minimizes the need for frequent calibration. Ideal for field applications, these meters are splash proof and the lamp and filter units are protected from dust or dirt by a transparent barrier. Display messages aid the user during routine operation. The auto-off feature will disengage the meter after 10 minutes of non-use in measuring mode or 1 hour while in calibration mode. HI 96771 utilizes an adaptation of Standard Methods for the Examination of Water and Wastewater, 20th Edition, 4500-Cl. The reaction between free chlorine and the reagents causes a yellow tint (UHR) or pink tint (LR) in the sample. Hanna #: HI 96771C. Range: UHR: 0 to 500 mg/L LR: 0.00 to 5.00 mg/LAccuracy: ±2 mg/L @ 100 mg/L ±0.02 mg/L @ 1.00 mg/LLight Source: Tungsten lamp with narrow band interface filter 525 nm Light Detection: Silicon Photocell Power Supply: 1 x 9V battery Auto Shut-Off: After 10 minutes of non-use in measurement mode. After 1 hour of non-use in calibration mode.Environment: 0 to 50°C (32 to 122°F); RH max 95% non-condensing Dimensions: 180 x 83 x 46 mm (7.1 x 3.3 x 1.8") Weight: 290 g (10 oz.) Method: Adaptation of Standard Methods, 20th edition, 4500-Cl. The reaction between chlorine and the reagents causes a yellow tint (UHR) or pink tint (LR) in the sample. HI 96771C is supplied with CAL CHECK™ standard cuvets, (2) sample cuvets with caps, 9V battery, tissue for wiping cuvets, scissors and instruction manual in a hard carrying case.

Documents & Videos

Responding to the user's requirements for analyzing high concentrations of chlorine, HANNA® offers HI 96771C, an auto-diagnostic portable photometer which measures free chlorine from 0 to 5.00 and 0 to 500 mg/L range. The advanced optical system employs a specialized tungsten lamp and a narrow band interference filter, assuring accurate readings. This instrument is equipped with Cal Check® validation function and standards to validate good performance at any time. Taking just a few short steps, the validation procedure is user-friendly and ensures that the meter is properly calibrated wherever you go. Hanna photometers use the exclusive ready-made, NiST traceable standards to verify the performance of the instrument and recalibrate if necessary. Cuvets are constructed from specialized optical glass to ensure the best and most consistent results. The positive locking system ensures that the cuvet is in the same position every time it is placed into the measuring cell. Our sample cell is designed to fit a cuvet with a wide neck to make it easier to add both sample and reagents. All instruments are factory calibrated and the electronic and optical design minimizes the need for frequent calibration. Ideal for field applications, these meters are splash proof and the lamp and filter units are protected from dust or dirt by a transparent barrier. Display messages aid the user during routine operation. The auto-off feature will disengage the meter after 10 minutes of non-use in measuring mode or 1 hour while in calibration mode. HI 96771 utilizes an adaptation of Standard Methods for the Examination of Water and Wastewater, 20th Edition, 4500-Cl. The reaction between free chlorine and the reagents causes a yellow tint (UHR) or pink tint (LR) in the sample. Hanna #: HI 96771C. Range: UHR: 0 to 500 mg/L LR: 0.00 to 5.00 mg/LAccuracy: ±2 mg/L @ 100 mg/L ±0.02 mg/L @ 1.00 mg/LLight Source: Tungsten lamp with narrow band interface filter 525 nm Light Detection: Silicon Photocell Power Supply: 1 x 9V battery Auto Shut-Off: After 10 minutes of non-use in measurement mode. After 1 hour of non-use in calibration mode.Environment: 0 to 50°C (32 to 122°F); RH max 95% non-condensing Dimensions: 180 x 83 x 46 mm (7.1 x 3.3 x 1.8") Weight: 290 g (10 oz.) Method: Adaptation of Standard Methods, 20th edition, 4500-Cl. The reaction between chlorine and the reagents causes a yellow tint (UHR) or pink tint (LR) in the sample. HI 96771C is supplied with CAL CHECK™ standard cuvets, (2) sample cuvets with caps, 9V battery, tissue for wiping cuvets, scissors and instruction manual in a hard carrying case.

Ratings & Reviews

No reviews available

Be the first to Write a Review