HANNA HI98185-01 Portable Waterproof Multiparameter Meter with Graphic Display, Extended Calibration & PC Connectivity, Parameters: ISE/ORP/pH/Temperature, Electrical: 115V

This item is 230V; please verify this is the correct voltage for your needs.
  • Manufacturer Part No: HI98185-01
(0) No Reviews yet

PLEASE NOTE: Product images and descriptions may not exactly represent the product. Prior to making your purchase, please confirm that the manufacturer part number shown above matches the product you seek. Returns are not allowed for such differences if the correct manufacturer part number is shipped.

Item Number: HAN-HI98185-01
This item is discontinued. Please contact customer service at 512.836.1667 if you would like assistance finding an alternative item.

Details

HI 98185 is a fine precision waterproof Temperature/ORP/ISE and pH Meter in HANNA's high-end portable series. A backlit 128 x 64 pixel graphic LCD provides high-quality resolution in this hand-held instrument. This meter comes equipped with the technologically advanced combined pH/temperature electrode, HI 72911B . Choose from 7 standard buffers and 5 custom buffers to obtain up to 5 points for calibration and achieve high precision readings with an accuracy of 0.001 and resolution up to +0.001. HANNA's signature Calibration Check® maintains a calibration history and monitors the pH electrode and buffers during calibration; while the electrode's condition is continuously displayed during measuring mode.Exchange out the pH/temperature electrode for an ORP sensor to obtain mV readings in the +2000 range. HI 98185 has auto recognition of 15 different ISE sensors and can be calibrated with up to 5 points and 6 standard buffers (choice of units). This unit allows an extensive choice of measurement units (ppm, ppt, g/L, ppb, ug/L, mg/mL, M, mol/L, mmol/L, % w/v, user) and has an expanded measuring range of 1.00 x 10-7 to 9.99 x 10-10.Press Auto-Hold while measuring and once stabilized, the current reading will remain displayed for your convenience in documenting. Or switch to log-on-demand mode and record and save up to 300 samples. Return to the lab and download all data to your PC with the USB connection and Hanna's HI 92000 software. OUT OF CALIBRATION RANGE WARNING can be engaged to alert the user in the event that a reading is taken too far from the calibration's periphery. A combination of dedicated and soft keys allows facile, intuitive operation in a choice of languages. Comprehensive GLP data are directly accessible by pressing the GLP key. Access the contextual Help Menu to obtain on-screen information and assistance about each feature at the touch of a button.Designed for field use, this instrument can be easily operated with one hand and is housed in a rugged carrying case. With an extended battery life of up to 200 hours the user is assured of a long operation time. The inductive charger can either be plugged into a standard 115V socket with the adapter included or a 12 Vdc source, such as a car's 12 V accessory outlet. Hanna #: 98185-01. (115V Listed - 230V available - Please Inquire) • • SPECIFICATIONS • • • Range (pH): -2.0 to 20.0; -2.00 to 20.00; -2.000 to 20.000 pH• Resolution (pH): 0.1; 0.01; 0.001 pH• Accuracy (pH): ±0.01; ±0.002 pH• Range (mV): ±2000 mV • Resolution (mV): 0.1 mV • Accuracy (mV): ±0.2 mV• Range (ISE): From 1.00 x 10(-7) to 10(10) concentration. (Choice of Units).• Resolution (ISE): 3 digits 0.01; 0.1; 1; 10 concentration • Accuracy (ISE): ±0.5% of reading (monovalent ions), ±1% of reading (divalent ions) • Range (Temperature): -20.0 to 120.0 °C (-4.0 to 248.0°F) • Resolution (Temperature): 0.1°C (0.1°F) • Accuracy (Temperature): ±0.4°C (±0.8°F) (excluding probe error) • Calibration (pH): Up to 5 point calibration, 7 standard buffers available (1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) + 5 custom buffers.• Calibration (ISE): Up to 5 point calibration, 6 standard solutions (Choice of Units).• Calibration Slope: From 80 to 110% • Temperature Compensation: Manual or Automatic from -20.0 to 120.0°C (-4.0 to 248.0°F) • Probe: HI 72911B pH electrode w/BNC - Temperature Combined. • Logging: 300 Samples• Input Impedance: 10(12) Ohms • PC Connection: Opto-Isolated USB (with HI 92000 Software)• Battery Type / Life: 4) 1.2V AA rechargeable batteries/ approx. 200 Hours continuous use (without backlight) • Recharger: Inductive recharger (included) • Auto Shut-off: User Selectable: 5, 10, 30, 60 min or can be disabled • Environment: IP67.• Dimensions: 226.5 x 95 x 52 mm (8.9 x 3.75 x 2") • Weight: 525g

Documents & Videos

HI 98185 is a fine precision waterproof Temperature/ORP/ISE and pH Meter in HANNA's high-end portable series. A backlit 128 x 64 pixel graphic LCD provides high-quality resolution in this hand-held instrument. This meter comes equipped with the technologically advanced combined pH/temperature electrode, HI 72911B . Choose from 7 standard buffers and 5 custom buffers to obtain up to 5 points for calibration and achieve high precision readings with an accuracy of 0.001 and resolution up to +0.001. HANNA's signature Calibration Check® maintains a calibration history and monitors the pH electrode and buffers during calibration; while the electrode's condition is continuously displayed during measuring mode.Exchange out the pH/temperature electrode for an ORP sensor to obtain mV readings in the +2000 range. HI 98185 has auto recognition of 15 different ISE sensors and can be calibrated with up to 5 points and 6 standard buffers (choice of units). This unit allows an extensive choice of measurement units (ppm, ppt, g/L, ppb, ug/L, mg/mL, M, mol/L, mmol/L, % w/v, user) and has an expanded measuring range of 1.00 x 10-7 to 9.99 x 10-10.Press Auto-Hold while measuring and once stabilized, the current reading will remain displayed for your convenience in documenting. Or switch to log-on-demand mode and record and save up to 300 samples. Return to the lab and download all data to your PC with the USB connection and Hanna's HI 92000 software. OUT OF CALIBRATION RANGE WARNING can be engaged to alert the user in the event that a reading is taken too far from the calibration's periphery. A combination of dedicated and soft keys allows facile, intuitive operation in a choice of languages. Comprehensive GLP data are directly accessible by pressing the GLP key. Access the contextual Help Menu to obtain on-screen information and assistance about each feature at the touch of a button.Designed for field use, this instrument can be easily operated with one hand and is housed in a rugged carrying case. With an extended battery life of up to 200 hours the user is assured of a long operation time. The inductive charger can either be plugged into a standard 115V socket with the adapter included or a 12 Vdc source, such as a car's 12 V accessory outlet. Hanna #: 98185-01. (115V Listed - 230V available - Please Inquire) • • SPECIFICATIONS • • • Range (pH): -2.0 to 20.0; -2.00 to 20.00; -2.000 to 20.000 pH• Resolution (pH): 0.1; 0.01; 0.001 pH• Accuracy (pH): ±0.01; ±0.002 pH• Range (mV): ±2000 mV • Resolution (mV): 0.1 mV • Accuracy (mV): ±0.2 mV• Range (ISE): From 1.00 x 10(-7) to 10(10) concentration. (Choice of Units).• Resolution (ISE): 3 digits 0.01; 0.1; 1; 10 concentration • Accuracy (ISE): ±0.5% of reading (monovalent ions), ±1% of reading (divalent ions) • Range (Temperature): -20.0 to 120.0 °C (-4.0 to 248.0°F) • Resolution (Temperature): 0.1°C (0.1°F) • Accuracy (Temperature): ±0.4°C (±0.8°F) (excluding probe error) • Calibration (pH): Up to 5 point calibration, 7 standard buffers available (1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) + 5 custom buffers.• Calibration (ISE): Up to 5 point calibration, 6 standard solutions (Choice of Units).• Calibration Slope: From 80 to 110% • Temperature Compensation: Manual or Automatic from -20.0 to 120.0°C (-4.0 to 248.0°F) • Probe: HI 72911B pH electrode w/BNC - Temperature Combined. • Logging: 300 Samples• Input Impedance: 10(12) Ohms • PC Connection: Opto-Isolated USB (with HI 92000 Software)• Battery Type / Life: 4) 1.2V AA rechargeable batteries/ approx. 200 Hours continuous use (without backlight) • Recharger: Inductive recharger (included) • Auto Shut-off: User Selectable: 5, 10, 30, 60 min or can be disabled • Environment: IP67.• Dimensions: 226.5 x 95 x 52 mm (8.9 x 3.75 x 2") • Weight: 525g

Ratings & Reviews

No reviews available

Be the first to Write a Review