HANNA HI98360 Portable Waterproof Conductivity/TDS/NaCl/Temperature Meter with PC Connectivity & Auto Endpoint, Multi-Range: 0 to 500000 Microsiemens/cm

  • Manufacturer Part No: HI98360
(0) No Reviews yet

PLEASE NOTE: Product images and descriptions may not exactly represent the product. Prior to making your purchase, please confirm that the manufacturer part number shown above matches the product you seek. Returns are not allowed for such differences if the correct manufacturer part number is shipped.

Item Number: HAN-HI98360
This item is discontinued. Please contact customer service at 512.836.1667 if you would like assistance finding an alternative item.

Details

HI 98360 is a rugged waterproof conductivity meter, which combines versatility and reliability with ease of use. This portable instrument is equipped with an auto-ranging feature and allows the user to measure EC and TDS with the resolution that best fits your sample. Reference temperature compensation can be set at 25 or 20°C, as required by the European water analysis regulation for conductivity measurements. All readings can be stored and then transferred to a PC through the RS232 serial port. The "Auto Endpoint" feature makes HI 98360 the ideal meter for field measurements: after entering this mode, the instrument will automatically freeze stable readings on the LCD. HI 76309/1.5 is a 4-ring potentiometric probe (included) for EC/TDS and temperature measurements. HI 76309/1.5 features a PVC body, stainless steel sensor and 1.5m (4.9') screened cable. Hanna #: HI 98360. • Range (Conductivity): 0.00 to 29.99 µS/cm; 30.0 to 299.9 µS/cm; 300 to 2999 µS/cm; 3.00 to 29.99 mS/cm; 30.0 to 200.0 mS/cm; up to 500.0 mS/cm (actual EC) • Range (TDS): 0.00 to 14.99 ppm (mg/L); 15.0 to 149.9 ppm (mg/L); 150 to 1499 ppm (mg/L); 1.50 to 14.99 g/L; 15.0 to 100.0 g/L up to 400.0 g/L (actual TDS) • Range (NaCl): 0.0 to 400.0% • Range (Temperature): 9.9 to 120.0°C • Resolution (Conductivity): 0.01 µS/cm; 0.1 µS/cm; 1 µS/cm; 0.01 mS/cm; 0.1 mS/cm • Resolution (TDS): 0.01 ppm (mg/L); 0.1 ppm (mg/L); 1 ppm (mg/L); 0.01 g/L; 0.1 g/L • Resolution (NaCl): 0.1% • Resolution (Temperature): 0.1°C • Accuracy (EC): ±0.5% of reading • Accuracy (TDS): ±0.5% of reading • Accuracy (NaCl): ±0.5% of reading • Accuracy (Temperature): ±0.4°C • Calibration (Conductivity): Automatic, 1 point, with 6 memorized values (84, 1413, 5000, 12880, 80000 and 111800 µS/cm) Calibration (NaCl): 1 point, with HI 7037 calibration solution (not included) • Calibration Temperature: 2 point, at 0 and 50°C (32 to 122°F) • Temperature Compensation: Automatic or manual, 0 to 60°C (32 to 140°F); can be disable for measuring actual EC and TDS • Temperature Coefficient: Adjustable from 0.00 to 6.00%/°C (EC and TDS only) • TDS Conversion Factor: Adjustable from 0.40 to 0.80 • Data Logging: Up to 250 samples • Probe: HI 76309/1.5, with 1.5 m (4.9') cable (included) • Power Supply: 4 x 1.5V AA batteries (included) or 12 Vdc input; auto-off after 5 minutes of non-use (can be disabled) • Environment: 0 to 50°C (32 to 122°F); RH max 100% • Dimensions: 196 x 80 x60 mm (7.7 x 3.1 x 2.4") • Weight: 500 g (1.1 lb.)

Documents & Videos

HI 98360 is a rugged waterproof conductivity meter, which combines versatility and reliability with ease of use. This portable instrument is equipped with an auto-ranging feature and allows the user to measure EC and TDS with the resolution that best fits your sample. Reference temperature compensation can be set at 25 or 20°C, as required by the European water analysis regulation for conductivity measurements. All readings can be stored and then transferred to a PC through the RS232 serial port. The "Auto Endpoint" feature makes HI 98360 the ideal meter for field measurements: after entering this mode, the instrument will automatically freeze stable readings on the LCD. HI 76309/1.5 is a 4-ring potentiometric probe (included) for EC/TDS and temperature measurements. HI 76309/1.5 features a PVC body, stainless steel sensor and 1.5m (4.9') screened cable. Hanna #: HI 98360. • Range (Conductivity): 0.00 to 29.99 µS/cm; 30.0 to 299.9 µS/cm; 300 to 2999 µS/cm; 3.00 to 29.99 mS/cm; 30.0 to 200.0 mS/cm; up to 500.0 mS/cm (actual EC) • Range (TDS): 0.00 to 14.99 ppm (mg/L); 15.0 to 149.9 ppm (mg/L); 150 to 1499 ppm (mg/L); 1.50 to 14.99 g/L; 15.0 to 100.0 g/L up to 400.0 g/L (actual TDS) • Range (NaCl): 0.0 to 400.0% • Range (Temperature): 9.9 to 120.0°C • Resolution (Conductivity): 0.01 µS/cm; 0.1 µS/cm; 1 µS/cm; 0.01 mS/cm; 0.1 mS/cm • Resolution (TDS): 0.01 ppm (mg/L); 0.1 ppm (mg/L); 1 ppm (mg/L); 0.01 g/L; 0.1 g/L • Resolution (NaCl): 0.1% • Resolution (Temperature): 0.1°C • Accuracy (EC): ±0.5% of reading • Accuracy (TDS): ±0.5% of reading • Accuracy (NaCl): ±0.5% of reading • Accuracy (Temperature): ±0.4°C • Calibration (Conductivity): Automatic, 1 point, with 6 memorized values (84, 1413, 5000, 12880, 80000 and 111800 µS/cm) Calibration (NaCl): 1 point, with HI 7037 calibration solution (not included) • Calibration Temperature: 2 point, at 0 and 50°C (32 to 122°F) • Temperature Compensation: Automatic or manual, 0 to 60°C (32 to 140°F); can be disable for measuring actual EC and TDS • Temperature Coefficient: Adjustable from 0.00 to 6.00%/°C (EC and TDS only) • TDS Conversion Factor: Adjustable from 0.40 to 0.80 • Data Logging: Up to 250 samples • Probe: HI 76309/1.5, with 1.5 m (4.9') cable (included) • Power Supply: 4 x 1.5V AA batteries (included) or 12 Vdc input; auto-off after 5 minutes of non-use (can be disabled) • Environment: 0 to 50°C (32 to 122°F); RH max 100% • Dimensions: 196 x 80 x60 mm (7.7 x 3.1 x 2.4") • Weight: 500 g (1.1 lb.)

Ratings & Reviews

No reviews available

Be the first to Write a Review