Macron™ 5557-14 Sulfuric Acid, 98%, AR Select Grade for Trace Metal Analysis, 500mL Glass Bottle (Case of 6)

Notice: Hazardous chemicals and products will incur additional Hazmat Fees and/or mandatory shipment via LTL Motor Freight
  • 6 x 500mL Glass Bottles/Case
  • Manufacturer Part No: MK-5557-14
(0) No Reviews yet

PLEASE NOTE: Product images and descriptions may not exactly represent the product. Prior to making your purchase, please confirm that the manufacturer part number shown above matches the product you seek. Returns are not allowed for such differences if the correct manufacturer part number is shipped.

Item Number: MAL-5557-14
$330.72

Sold in: Cases

UnitMSRPYour PriceStock StatusQty
Case357.78330.72Lead Time

New

Details

Product Specifications

TESTSPECIFICATION
Meets ACS Reagent Chemical Requirements
For Laboratory,Research,or Manufacturing Use
ACS - Assay (H₂SO₄) (by acidimetry)95.0 - 98.0 %
AppearancePasses Test
ACS - Ammonium (NH₄)<= 0.5 ppm
ACS - Arsenic and Antimony (as As)<= 0.003 ppm
ACS - Chloride (Cl)<= 0.05 ppm
ACS - Color (APHA)<= 8
ACS - Heavy Metals (as Pb)<= 0.1 ppm
ACS - Nitrate (NO₃)<= 0.1 ppm
ACS - Residue after Ignition<= 1 ppm
ACS - Substances Reducing Permanganate (as SO₂)<= 2 ppm
Determine by Flame Photometry & ICP - Aluminum (Al)<= 50.0 ppb
Determine by Flame Photometry & ICP - Barium (Ba)<= 10.0 ppb
Determine by Flame Photometry & ICP - Beryllium (Be)<= 50.0 ppb
Determine by Flame Photometry & ICP - Bismuth (Bi)<= 100.0 ppb
Determine by Flame Photometry & ICP - Boron (B)<= 10.0 ppb
Determine by Flame Photometry & ICP - Cadmium (Cd)<= 5.0 ppb
Determine by Flame Photometry & ICP - Calcium (Ca)<= 50.0 ppb
Determine by Flame Photometry & ICP - Chromium (Cr)<= 10.0 ppb
Determine by Flame Photometry & ICP - Cobalt (Co)<= 5.0 ppb
Determine by Flame Photometry & ICP - Copper (Cu)<= 5.0 ppb
Determine by Flame Photometry & ICP - Gallium (Ga)<= 100.0 ppb
Determine by Flame Photometry & ICP - Germanium (Ge)<= 100.0 ppb
Determine by Flame Photometry & ICP - Gold (Au)<= 100.0 ppb
Determine by Flame Photometry & ICP - Iron (Fe)<= 50.0 ppb
Determine by Flame Photometry & ICP - Lead (Pb)<= 1.0 ppb
Determine by Flame Photometry & ICP - Lithium (Li)<= 10.0 ppb
Determine by Flame Photometry & ICP - Magnesium (Mg)<= 50.0 ppb
Determine by Flame Photometry & ICP - Manganese (Mn)<= 5.0 ppb
Determine by Flame Photometry & ICP - Mercury (Hg)<= 1.0 ppb
Determine by Flame Photometry & ICP - Molybdenum (Mo)<= 10.0 ppb
Determine by Flame Photometry & ICP - Nickel (Ni)<= 5.0 ppb
Determine by Flame Photometry & ICP - Potassium (K)<= 50.0 ppb
Determine by Flame Photometry & ICP - Silicon (Si)<= 100.0 ppb
Determine by Flame Photometry & ICP - Silver (Ag)<= 10.0 ppb
Determine by Flame Photometry & ICP - Sodium (Na)<= 500.0 ppb
Determine by Flame Photometry & ICP - Strontium (Sr)<= 10.0 ppb
Determine by Flame Photometry & ICP - Thallium (Tl)<= 200.0 ppb
Determine by Flame Photometry & ICP - Tin (Sn)<= 50.0 ppb
Determine by Flame Photometry & ICP - Vanadium (V)<= 10.0 ppb
Determine by Flame Photometry & ICP - Zinc (Zn)

Product Specifications

TESTSPECIFICATION
Meets ACS Reagent Chemical Requirements
For Laboratory,Research,or Manufacturing Use
ACS - Assay (H₂SO₄) (by acidimetry)95.0 - 98.0 %
AppearancePasses Test
ACS - Ammonium (NH₄)<= 0.5 ppm
ACS - Arsenic and Antimony (as As)<= 0.003 ppm
ACS - Chloride (Cl)<= 0.05 ppm
ACS - Color (APHA)<= 8
ACS - Heavy Metals (as Pb)<= 0.1 ppm
ACS - Nitrate (NO₃)<= 0.1 ppm
ACS - Residue after Ignition<= 1 ppm
ACS - Substances Reducing Permanganate (as SO₂)<= 2 ppm
Determine by Flame Photometry & ICP - Aluminum (Al)<= 50.0 ppb
Determine by Flame Photometry & ICP - Barium (Ba)<= 10.0 ppb
Determine by Flame Photometry & ICP - Beryllium (Be)<= 50.0 ppb
Determine by Flame Photometry & ICP - Bismuth (Bi)<= 100.0 ppb
Determine by Flame Photometry & ICP - Boron (B)<= 10.0 ppb
Determine by Flame Photometry & ICP - Cadmium (Cd)<= 5.0 ppb
Determine by Flame Photometry & ICP - Calcium (Ca)<= 50.0 ppb
Determine by Flame Photometry & ICP - Chromium (Cr)<= 10.0 ppb
Determine by Flame Photometry & ICP - Cobalt (Co)<= 5.0 ppb
Determine by Flame Photometry & ICP - Copper (Cu)<= 5.0 ppb
Determine by Flame Photometry & ICP - Gallium (Ga)<= 100.0 ppb
Determine by Flame Photometry & ICP - Germanium (Ge)<= 100.0 ppb
Determine by Flame Photometry & ICP - Gold (Au)<= 100.0 ppb
Determine by Flame Photometry & ICP - Iron (Fe)<= 50.0 ppb
Determine by Flame Photometry & ICP - Lead (Pb)<= 1.0 ppb
Determine by Flame Photometry & ICP - Lithium (Li)<= 10.0 ppb
Determine by Flame Photometry & ICP - Magnesium (Mg)<= 50.0 ppb
Determine by Flame Photometry & ICP - Manganese (Mn)<= 5.0 ppb
Determine by Flame Photometry & ICP - Mercury (Hg)<= 1.0 ppb
Determine by Flame Photometry & ICP - Molybdenum (Mo)<= 10.0 ppb
Determine by Flame Photometry & ICP - Nickel (Ni)<= 5.0 ppb
Determine by Flame Photometry & ICP - Potassium (K)<= 50.0 ppb
Determine by Flame Photometry & ICP - Silicon (Si)<= 100.0 ppb
Determine by Flame Photometry & ICP - Silver (Ag)<= 10.0 ppb
Determine by Flame Photometry & ICP - Sodium (Na)<= 500.0 ppb
Determine by Flame Photometry & ICP - Strontium (Sr)<= 10.0 ppb
Determine by Flame Photometry & ICP - Thallium (Tl)<= 200.0 ppb
Determine by Flame Photometry & ICP - Tin (Sn)<= 50.0 ppb
Determine by Flame Photometry & ICP - Vanadium (V)<= 10.0 ppb
Determine by Flame Photometry & ICP - Zinc (Zn)

Ratings & Reviews

No reviews available

Be the first to Write a Review