PLEASE NOTE: Product images and descriptions may not exactly represent the product. Prior to making your purchase, please confirm that the manufacturer part number shown above matches the product you seek. Returns are not allowed for such differences if the correct manufacturer part number is shipped.

Item Number: MAL-H488-10
$509.43

Sold in: Cases

UnitMSRPYour PriceStock StatusQty
Case618.50509.43Lead Time

New

Details

Product Specifications

TESTSPECIFICATION
For Laboratory,Research,or Manufacturing Use
AppearancePasses Test
ACS - Assay (CH₃OH) (by GC, corrected for water)>= 99.9 %
Carbonyl Compounds - Acetone<= 0.001 %
Carbonyl Compounds - Acetaldehyde<= 0.001 %
Carbonyl Compounds - Formaldehyde<= 0.001 %
Color (APHA)<= 5
Residue after Evaporation<= 0.00010 %
Solubility in H₂OPasses Test
Substances Darkened by H₂SO₄Passes Test
Substances Reducing PermanganatePasses Test
Titrable Acid (meq/g)<= 0.0003
Titrable Base (meq/g)<= 0.0002
Water (H₂O)(by Karl Fischer titrn)<= 0.05 %
Ultraviolet Absorbance (1.00-cm cell vs. water) - 205 nm<= 1.00
Ultraviolet Absorbance (1.00-cm cell vs. water) - 210 nm<= 0.80
Ultraviolet Absorbance (1.00-cm cell vs. water) - 220 nm<= 0.25
Ultraviolet Absorbance (1.00-cm cell vs. water) - 230 nm<= 0.12
Ultraviolet Absorbance (1.00-cm cell vs. water) - 240 nm<= 0.05
Ultraviolet Absorbance (1.00-cm cell vs. water) - 260 nm<= 0.01
Ultraviolet Absorbance (1.00-cm cell vs. water) - 400 - 280 nm<= 0.005
Liquid Chromatography Suitability AbsorbancePasses Test
HPLC Gradient Elution (No Peak Greater than 25% of Full Scale)(0.005 au)Passes Test
ECD Sensitive Impurities (as Heptachl or Epoxide) Single Peak (ng/L)<= 5
Sum of the Peaks (ng/L)<= 10
FID Sensitive Impurities (as 2-Octano l) Single Peak (µg/L)<= 5
Sum of the Peaks (µg/L)<= 10
Fluorescence Trace Impurities, measured as Quinine Base - at Emission Maximum for Impurities<= 1.0 ppb

Documents & Videos

Product Specifications

TESTSPECIFICATION
For Laboratory,Research,or Manufacturing Use
AppearancePasses Test
ACS - Assay (CH₃OH) (by GC, corrected for water)>= 99.9 %
Carbonyl Compounds - Acetone<= 0.001 %
Carbonyl Compounds - Acetaldehyde<= 0.001 %
Carbonyl Compounds - Formaldehyde<= 0.001 %
Color (APHA)<= 5
Residue after Evaporation<= 0.00010 %
Solubility in H₂OPasses Test
Substances Darkened by H₂SO₄Passes Test
Substances Reducing PermanganatePasses Test
Titrable Acid (meq/g)<= 0.0003
Titrable Base (meq/g)<= 0.0002
Water (H₂O)(by Karl Fischer titrn)<= 0.05 %
Ultraviolet Absorbance (1.00-cm cell vs. water) - 205 nm<= 1.00
Ultraviolet Absorbance (1.00-cm cell vs. water) - 210 nm<= 0.80
Ultraviolet Absorbance (1.00-cm cell vs. water) - 220 nm<= 0.25
Ultraviolet Absorbance (1.00-cm cell vs. water) - 230 nm<= 0.12
Ultraviolet Absorbance (1.00-cm cell vs. water) - 240 nm<= 0.05
Ultraviolet Absorbance (1.00-cm cell vs. water) - 260 nm<= 0.01
Ultraviolet Absorbance (1.00-cm cell vs. water) - 400 - 280 nm<= 0.005
Liquid Chromatography Suitability AbsorbancePasses Test
HPLC Gradient Elution (No Peak Greater than 25% of Full Scale)(0.005 au)Passes Test
ECD Sensitive Impurities (as Heptachl or Epoxide) Single Peak (ng/L)<= 5
Sum of the Peaks (ng/L)<= 10
FID Sensitive Impurities (as 2-Octano l) Single Peak (µg/L)<= 5
Sum of the Peaks (µg/L)<= 10
Fluorescence Trace Impurities, measured as Quinine Base - at Emission Maximum for Impurities<= 1.0 ppb