Macron™ V551-10 Chloroform, UltimAR Analytical Reagent Grade for Liquid Chromatography & UV Spectrophotometry, 4L Glass Bottle
- 4 x 4L Glass Bottles/Case
- Manufacturer Part No: MK-V551-10
PLEASE NOTE: Product images and descriptions may not exactly represent the product. Prior to making your purchase, please confirm that the manufacturer part number shown above matches the product you seek. Returns are not allowed for such differences if the correct manufacturer part number is shipped.
Details
Product Specifications
TEST | SPECIFICATION |
For Laboratory,Research,or Manufacturing Use | |
ACS - Assay (CHCl₃) (by GC) | >= 99.8 % |
ACS - Stabilizer (amylene)(w/w) | 100 - 200 ppm |
ACS - Color (APHA) | <= 10 |
ACS - Residue after Evaporation | <= 2 ppm |
ACS - Water (H₂O)(by KF, coulometric) | <= 0.02 % |
ACS - Acetone, Aldehydes (as (CH₃)₂CO) (Approx. 0.005 %) | Passes Test |
ACS - Free Chlorine (as Cl) | Passes Test |
ACS - Lead (Pb) | <= 0.050 ppm |
ACS - Substances Darkened by H₂SO₄ | Passes Test |
Ultraviolet Absorbance (1.00-cm cell vs. water) - 245 nm | <= 1.00 |
Ultraviolet Absorbance (1.00-cm cell vs. water) - 255 nm | <= 0.25 |
Ultraviolet Absorbance (1.00-cm cell vs. water) - 260 nm | <= 0.15 |
Ultraviolet Absorbance (1.00-cm cell vs. water) - 270 nm | <= 0.05 |
Ultraviolet Absorbance (1.00-cm cell vs. water) - 275 - 400 nm | <= 0.01 |
Liquid Chromatography Suitability Absorbance | Passes Test |
Titrable Acid (µeq/g) | <= 0.3 |
Acid and Chloride | Passes Test |
Suitability for Use in Dithizone Tests | Passes Test |
Fluorescence Trace Impurities, measured as Quinine Base - at Emission Maximum for Impurities | <= 1.0 ppb |
Trace Impurities - GC-ECD Sensitive Impurities (as Heptachlor Epoxide) Single Peak (ng/L) | <= 5.0 ppb |
Trace Impurities - Sum of the Peaks (ng/L) | <= 10.0 ppb |
FID Sensitive Impurities (as 2-Octano l) Single Peak (µg/L) | <= 5 ppb |
FID - Sum of the Peaks (µg/L) | <= 10 |
Appearance (clear, colorless liquid) |
Documents & Videos
Product Specifications
TEST | SPECIFICATION |
For Laboratory,Research,or Manufacturing Use | |
ACS - Assay (CHCl₃) (by GC) | >= 99.8 % |
ACS - Stabilizer (amylene)(w/w) | 100 - 200 ppm |
ACS - Color (APHA) | <= 10 |
ACS - Residue after Evaporation | <= 2 ppm |
ACS - Water (H₂O)(by KF, coulometric) | <= 0.02 % |
ACS - Acetone, Aldehydes (as (CH₃)₂CO) (Approx. 0.005 %) | Passes Test |
ACS - Free Chlorine (as Cl) | Passes Test |
ACS - Lead (Pb) | <= 0.050 ppm |
ACS - Substances Darkened by H₂SO₄ | Passes Test |
Ultraviolet Absorbance (1.00-cm cell vs. water) - 245 nm | <= 1.00 |
Ultraviolet Absorbance (1.00-cm cell vs. water) - 255 nm | <= 0.25 |
Ultraviolet Absorbance (1.00-cm cell vs. water) - 260 nm | <= 0.15 |
Ultraviolet Absorbance (1.00-cm cell vs. water) - 270 nm | <= 0.05 |
Ultraviolet Absorbance (1.00-cm cell vs. water) - 275 - 400 nm | <= 0.01 |
Liquid Chromatography Suitability Absorbance | Passes Test |
Titrable Acid (µeq/g) | <= 0.3 |
Acid and Chloride | Passes Test |
Suitability for Use in Dithizone Tests | Passes Test |
Fluorescence Trace Impurities, measured as Quinine Base - at Emission Maximum for Impurities | <= 1.0 ppb |
Trace Impurities - GC-ECD Sensitive Impurities (as Heptachlor Epoxide) Single Peak (ng/L) | <= 5.0 ppb |
Trace Impurities - Sum of the Peaks (ng/L) | <= 10.0 ppb |
FID Sensitive Impurities (as 2-Octano l) Single Peak (µg/L) | <= 5 ppb |
FID - Sum of the Peaks (µg/L) | <= 10 |
Appearance (clear, colorless liquid) |