PLEASE NOTE: Product images and descriptions may not exactly represent the product. Prior to making your purchase, please confirm that the manufacturer part number shown above matches the product you seek. Returns are not allowed for such differences if the correct manufacturer part number is shipped.
Details
Product Specifications
TEST | SPECIFICATION |
For Laboratory,Research,or Manufacturing Use | |
ACS - Assay (CH₃COOCH₂CH₃) (by GC, corrected for water) | >= 99.6 % |
ACS - Color (APHA) | <= 10 |
ACS - Residue after Evaporation | <= 1 ppm |
ACS - Titrable Acid (µeq/g) | <= 0.8 |
ACS - Water (H₂O)(by KF, coulometric) | <= 0.04 % |
Ultraviolet Absorbance (1.00-cm cell vs. water) - 255 nm | <= 1.00 |
Ultraviolet Absorbance (1.00-cm cell vs. water) - 257 nm | <= 0.50 |
Ultraviolet Absorbance (1.00-cm cell vs. water) - 263 nm | <= 0.10 |
Ultraviolet Absorbance (1.00-cm cell vs. water) - 265 nm | <= 0.05 |
Ultraviolet Absorbance (1.00-cm cell vs. water) - 275 nm | <= 0.05 |
Ultraviolet Absorbance (1.00-cm cell vs. water) - 280 nm | <= 0.02 |
Ultraviolet Absorbance (1.00-cm cell vs. water) - 330 - 400 nm | <= 0.01 |
Substances Darkened by H₂SO₄ | Passes Test |
Fluorescence Trace Impurities, measured as Quinine Base - at Emission Maximum for Impurities | <= 1.0 ppb |
ECD Sensitive Impurities (as Heptachl or Epoxide) Single Peak (ng/L) | <= 10 ppb |
FID Sensitive Impurities (as 2-Octano l) Single Peak (µg/L) | <= 5 ppb |
Documents & Videos
Product Specifications
TEST | SPECIFICATION |
For Laboratory,Research,or Manufacturing Use | |
ACS - Assay (CH₃COOCH₂CH₃) (by GC, corrected for water) | >= 99.6 % |
ACS - Color (APHA) | <= 10 |
ACS - Residue after Evaporation | <= 1 ppm |
ACS - Titrable Acid (µeq/g) | <= 0.8 |
ACS - Water (H₂O)(by KF, coulometric) | <= 0.04 % |
Ultraviolet Absorbance (1.00-cm cell vs. water) - 255 nm | <= 1.00 |
Ultraviolet Absorbance (1.00-cm cell vs. water) - 257 nm | <= 0.50 |
Ultraviolet Absorbance (1.00-cm cell vs. water) - 263 nm | <= 0.10 |
Ultraviolet Absorbance (1.00-cm cell vs. water) - 265 nm | <= 0.05 |
Ultraviolet Absorbance (1.00-cm cell vs. water) - 275 nm | <= 0.05 |
Ultraviolet Absorbance (1.00-cm cell vs. water) - 280 nm | <= 0.02 |
Ultraviolet Absorbance (1.00-cm cell vs. water) - 330 - 400 nm | <= 0.01 |
Substances Darkened by H₂SO₄ | Passes Test |
Fluorescence Trace Impurities, measured as Quinine Base - at Emission Maximum for Impurities | <= 1.0 ppb |
ECD Sensitive Impurities (as Heptachl or Epoxide) Single Peak (ng/L) | <= 10 ppb |
FID Sensitive Impurities (as 2-Octano l) Single Peak (µg/L) | <= 5 ppb |