Oakton® WD-19505-00 Eutech Instruments® COND 200 Conductivity Digital Controller, On/Off Control, Range: 0 to 200000 Microsiemens/cm, Dimensions: 96 x 48 x 150-Millimeter

  • Two set point, two SPDT relay operation for low/high, high/low, low/low, or high/high control, or use one relay to operate an alarm
  • Intuitive user interface; scrolling 14-segment LED display makes setup simple
  • Reliable power supply withstands voltage fluctuation from 85 to 265 VAC
  • Adjustable hysteresis prevents rapid relay switching near set points
  • Galvanically isolated 4-20 mA output for remote monitoring or hard copy recording
  • Manufacturer Part No: EW-19505-00
(0) No Reviews yet

PLEASE NOTE: Product images and descriptions may not exactly represent the product. Prior to making your purchase, please confirm that the manufacturer part number shown above matches the product you seek. Returns are not allowed for such differences if the correct manufacturer part number is shipped.

Item Number: OAK-WD-19505-00
This item is discontinued. Please contact customer service at 512.836.1667 if you would like assistance finding an alternative item.

Details

The Oakton 1/8-DIN Controller sturdy - compact controller features two relays for low/high - low/low or high/high control—activate an alarm - pump or other device. The controller features 4 to 20 mA transmitter/recorder output for data logging - and adjustable temperature coefficient and selectable cell constants for best accuracy in a wide variety of solutions. Range selection from menu allows the user to define range without the use of dip switches. Two-level password protection allows user to access all controller functions or just calibration features - which prevents tampering with setup functions. Built-in memory backup retains setup even if power fails - and lets the user configure unit before installation. Removable terminal strips make connections quick and easy. Use with 0.1 and 1.0 cell constan. Symmetrical mode operation eliminates electrical noise problems when used with solution ground. Specifications: Control Type: On/Off - Conductivity Range: 0 to 20µS - 0 to 200µS - 0 to 2000µS - 0 to 10mS - 0 to 20mS - 0 to 200mS - Resolution: 0.01µS - 0.1µS - 1µS - 0.01mS - 0.1mS - 1mS - Accuracy: +/- 1% full scale of reading - Temperature Range: -10 to 110°C - +/- 0.5°C (resolution 0.1°C) - Automatic temperature compensation selectable between automatic or manual from 5 to 50°C - Universal power supply input from 85 to 250 VAC/DC allows use at multiple sites. Galvanically isolated 4 to 20 mA output for logging data. These 1/8-DIN controllers display the measured parameter value or temperature with a touch of a button. Industrial Applications: Use to treat batches of incoming process water - rinse water treatment - recirculating water treatment - and wastewater. Suitable for pH or ORP control of plating tanks and chemical processing tanks. Ideal as a low cost monitor with alarms for batch and process applications. Aquaculture Applications: Use for pH or ORP control in fish ponds. General Applications: Ideal for virtually any batch type application where pH or ORP control or adjustment is needed. Use as ORP monitor for ozone systems and general purpose pH monitor for all types of water treatment and chemical processes. Oakton #: WD-19505-00

Documents & Videos

The Oakton 1/8-DIN Controller sturdy - compact controller features two relays for low/high - low/low or high/high control—activate an alarm - pump or other device. The controller features 4 to 20 mA transmitter/recorder output for data logging - and adjustable temperature coefficient and selectable cell constants for best accuracy in a wide variety of solutions. Range selection from menu allows the user to define range without the use of dip switches. Two-level password protection allows user to access all controller functions or just calibration features - which prevents tampering with setup functions. Built-in memory backup retains setup even if power fails - and lets the user configure unit before installation. Removable terminal strips make connections quick and easy. Use with 0.1 and 1.0 cell constan. Symmetrical mode operation eliminates electrical noise problems when used with solution ground. Specifications: Control Type: On/Off - Conductivity Range: 0 to 20µS - 0 to 200µS - 0 to 2000µS - 0 to 10mS - 0 to 20mS - 0 to 200mS - Resolution: 0.01µS - 0.1µS - 1µS - 0.01mS - 0.1mS - 1mS - Accuracy: +/- 1% full scale of reading - Temperature Range: -10 to 110°C - +/- 0.5°C (resolution 0.1°C) - Automatic temperature compensation selectable between automatic or manual from 5 to 50°C - Universal power supply input from 85 to 250 VAC/DC allows use at multiple sites. Galvanically isolated 4 to 20 mA output for logging data. These 1/8-DIN controllers display the measured parameter value or temperature with a touch of a button. Industrial Applications: Use to treat batches of incoming process water - rinse water treatment - recirculating water treatment - and wastewater. Suitable for pH or ORP control of plating tanks and chemical processing tanks. Ideal as a low cost monitor with alarms for batch and process applications. Aquaculture Applications: Use for pH or ORP control in fish ponds. General Applications: Ideal for virtually any batch type application where pH or ORP control or adjustment is needed. Use as ORP monitor for ozone systems and general purpose pH monitor for all types of water treatment and chemical processes. Oakton #: WD-19505-00