Oakton® WD-35408-00 CON 600 Portable Waterproof Conductivity/TDS Meter with Probe, Conductivity Range: 0 to 200000 Microsiemens/cm, TDS Range: 0 to 500000ppm, Temperature Dual Range: -10 to 110°C/14 to 230°F

Item is discontinued. The manufacturer’s recommended alternate is item# 35660-72
  • Features include large backlit graphic display, built-in real-time clock, advanced data management, set point alarms, password protection
  • Conductivity, TDS, resistivity, salinity measure from pure water to seawater
  • The IP67-rated housing allows use in dirty and wet environments without harm to the meter
  • Programmable 'calibration due' date for increased data integrity
  • Accept 2-cell and 4-cell conductivity probes which measure over a broad conductivity range up to 500 mS/cm
  • Manufacturer Part No: EW-35408-00
(0) No Reviews yet

PLEASE NOTE: Product images and descriptions may not exactly represent the product. Prior to making your purchase, please confirm that the manufacturer part number shown above matches the product you seek. Returns are not allowed for such differences if the correct manufacturer part number is shipped.

Item Number: OAK-WD-35408-00
This item is discontinued. Please contact customer service at 512.836.1667 if you would like assistance finding an alternative item.

New

Details

The Oakton CON 600 conductivity meters has a large backlit graphic display that is multi-line with electrode status indicator - calibration data - and more. The user-settable 'calibration due' alarm makes out-of-date or unperformed calibrations a thing of the past. The built-in real-time clock features time-and-date stamping that meets Good Laboratory Practice (GLP) standards. With advanced data management capabilities the Oakton CON 600 conductivity meter stores up to 500 data sets and offers simple download via Infrared IRDA wireless interface. Oakton CON 600 conductivity meters have set point alarms to provide an audible warning when readings are outside set points limit. The Oakton CON 600 conductivity meter accepts 2-cell and 4-cell conductivity probes for taking measurements over a broad conductivity range up to 500 mS/cm. Password protection provides security for calibration and setup menus. Conductivity cells feature a built-in temperature sensor. Choose a cell with K = 1.0 for midrange measurements (epoxy body/stainless steel sensor; WD-35408-52) Specification: Conductivity Range: 0 to 200 mS. Conductivity Resolution: 0.01 - 0.1 µS; 0.001 - 0.01 - 0.1 mS. Conductivity Accuracy: +/- 1% full-scale. Salinity Range: 0 to 80 ppt. Salinity Resolution: 0.01 - 0.1 ppm; 0.001 - 0.01 ppt. Salinity Accuracy: +/- 1% full-scale. TDS Range: 0 to 200 ppt. TDS Resolution: 0.1 - 0.1 ppm; 0.001 - 0.01 - 0.1 ppt. TDS Accuracy: +/- 1% full-scale. Temp Range: 14 to 230°F (-10 to 110°C). Temp Resolution: 0.1. Temp Accuracy: +/- 0.9°C (+/- 0.5°C). Temp Coefficient: 0 to 10.0%/°C. Temperature Coefficient: linear or pure. Cell Constant: 0.1 to 10. Temperature Compensation: automatic or manual (selectable) from 0 to 100°C. Ambient operating temperature: 0 to 50°C (32 to 122°F). Power: four 1.5 V AA batteries (included) or optional universal AC adapter - up to 200 hours continuous use. Dimensions (L x W x H): meter: 7.5 x 3.75 x 2.25 inches (19 x 9.5 x 5.7cm); boxed: 9.2 x 9.2 x 2.75 inches (23 x 23 x 7cm). Weight: meter: 1 lb (0.45 kg); boxed: 2 lb (0.9 kg). Feature includes Rubber boot (WD-35418-86) which protects meter in rugged environments and optional adapter (WD-35418-83) 110/220 VAC. Oakton #: WD-35408-00

Documents & Videos

The Oakton CON 600 conductivity meters has a large backlit graphic display that is multi-line with electrode status indicator - calibration data - and more. The user-settable 'calibration due' alarm makes out-of-date or unperformed calibrations a thing of the past. The built-in real-time clock features time-and-date stamping that meets Good Laboratory Practice (GLP) standards. With advanced data management capabilities the Oakton CON 600 conductivity meter stores up to 500 data sets and offers simple download via Infrared IRDA wireless interface. Oakton CON 600 conductivity meters have set point alarms to provide an audible warning when readings are outside set points limit. The Oakton CON 600 conductivity meter accepts 2-cell and 4-cell conductivity probes for taking measurements over a broad conductivity range up to 500 mS/cm. Password protection provides security for calibration and setup menus. Conductivity cells feature a built-in temperature sensor. Choose a cell with K = 1.0 for midrange measurements (epoxy body/stainless steel sensor; WD-35408-52) Specification: Conductivity Range: 0 to 200 mS. Conductivity Resolution: 0.01 - 0.1 µS; 0.001 - 0.01 - 0.1 mS. Conductivity Accuracy: +/- 1% full-scale. Salinity Range: 0 to 80 ppt. Salinity Resolution: 0.01 - 0.1 ppm; 0.001 - 0.01 ppt. Salinity Accuracy: +/- 1% full-scale. TDS Range: 0 to 200 ppt. TDS Resolution: 0.1 - 0.1 ppm; 0.001 - 0.01 - 0.1 ppt. TDS Accuracy: +/- 1% full-scale. Temp Range: 14 to 230°F (-10 to 110°C). Temp Resolution: 0.1. Temp Accuracy: +/- 0.9°C (+/- 0.5°C). Temp Coefficient: 0 to 10.0%/°C. Temperature Coefficient: linear or pure. Cell Constant: 0.1 to 10. Temperature Compensation: automatic or manual (selectable) from 0 to 100°C. Ambient operating temperature: 0 to 50°C (32 to 122°F). Power: four 1.5 V AA batteries (included) or optional universal AC adapter - up to 200 hours continuous use. Dimensions (L x W x H): meter: 7.5 x 3.75 x 2.25 inches (19 x 9.5 x 5.7cm); boxed: 9.2 x 9.2 x 2.75 inches (23 x 23 x 7cm). Weight: meter: 1 lb (0.45 kg); boxed: 2 lb (0.9 kg). Feature includes Rubber boot (WD-35418-86) which protects meter in rugged environments and optional adapter (WD-35418-83) 110/220 VAC. Oakton #: WD-35408-00

Ratings & Reviews

No reviews available

Be the first to Write a Review