• Home
  • Oakton® WD-35607-40 CON 11 Portable Conductivity/TDS Meter, Conductivity Range: 0 to 199900 Microsi

Oakton® WD-35607-40 CON 11 Portable Conductivity/TDS Meter, Conductivity Range: 0 to 199900 Microsiemens/cm, TDS Range: 1 to 99900ppm, Temperature Range: -10 to 110°C

  • Dual display lets you see both conductivity (or TDS) and temperature at a glance
  • Features include built-in memory for up to 50 measurements, hold function, ready indicator, built-in stand, and auto-off function
  • Selectable manual or automatic temperature compensation as well as four-point conductivity calibration
  • Adjustable conductivity-to-TDS conversion factor from 0.4 to 1.0
  • Powered with four 1.5V AAA batteries (included) for greater than 200 hours continuous use or an optional 9V, 500mA AC adapter
  • Manufacturer: Oakton Instruments
  • Manufacturer Part No: OAK-35607-40
(0) No Reviews yet
Item Number: OAK-WD-35607-40

Details

The Oakton CON 11 Standard Conductivity and TDS Meter features a dual display that lets you see conductivity/TDS and temperature at a glance. The auto ranging feature spans across five ranges for fast response and the best resolution over a wide range. The meter has a built-in memory that stores up to 50 readings. The four-point conductivity calibration can be set to auto or manual and will calibrate one point per range for high +/- 1.0% full-scale accuracy. The Oakton CON 11 standard conductivity/TDS meter also features single or multi-point calibration for multi-range calibration of highest accuracy. The Oakton CON 11 standard conductivity/TDS meter has a selectable manual or automatic temperature compensation feature that provides great accuracy in any application. It also features an adjustable conductivity-to-TDS conversion factor from 0.4 to 1.0. The meter can be powered with either four 1.5V AAA batteries (included) for greater than 200 hours continuous use or an optional 9V - 500mA AC adapter for use in the field or at your benchtop. The Oakton CON 11 standard conductivity/TDS meter comes with a built-in stand for benchtop or long-term use. It also features a ready indicator which indicates when your measurement has stabilized - so you always record the best reading. The hold function freezes measurements for convenient reading and recording. An auto-off function turns the Oakton CON 11 standard conductivity/TDS meter off after 20 minutes of non-use to conserve batteries. The Oakton CON 11 standard conductivity/TDS meter is useful in a wide variety of applications. It is ideal for quick - accurate - routine testing checks of conductivity/TDS in labs and schools - as well as in water quality testing to assess hard water - untreated water - drinking water - incoming process water - and pool water. It is used in the industrial arena to check pollution control - metal finishing - cooling tower water - boiler water - brines - rinse tanks - ponds - re-circulating systems - and wastewater - and is also useful in the hydroponics and agricultural industries. Specifications: Conductivity range: 0.00 to 19.99µS - 0.0 to 199.9µS - 0 to 1999µS - 0.00 to 19.99mS - 0.00 to 199.9mS. Conductivity resolution: 0.01µS - 0.1µS - 1µS - 0.01mS - 0.1mS. Conductivity accuracy: +/-1% full scale. TDS range: 0.00 to 9.99ppm - 0.0 to 99.9ppm - 0 to 999ppm - 0.00 to 9.99ppt - 0.0 to 99.9ppt. TDS resolution: 0.01ppm - 0.1ppm - 1ppm - 0.01ppt - 0.1ppt. TDS accuracy: +/-1% full scale. Conductivity to TDS factor: adjustable from 0.4 to 1.0. Temperature compensation: automatic or manual from 0 to 100°C. Operating temperature: 0 to 50°C (32 to 122°F). Temperature coefficient: 0 to 10%/°C. Memory: up to 50 data sets. Power: four 1.5V AAA batteries (included) that give greater than 200 hours continuous use; optional 9V - 500mA AC adapter available. Dimensions (L x W x H): meter: 7.5 x 3.5 x 1.75 inches (19 x 9 x 4.5cm); boxed: 9.2 x 8.2 x 2.75 inches (23 x 23 x 7cm). Weight: meter: 1 lb (0.5 kg); boxed: 2 lb (0.9 kg). Accessories and replacement parts: Conductivity cells feature a built-in temperature sensor. Choose a cell with K = 0.1 for low-range measurements (epoxy body/platinum sensor; WD-35608-55); K = 1.0 for midrange measurements (epoxy body/stainless steel sensor; WD-35608-50); or K = 10 for high-range measurements (epoxy body/platinum sensor; WD-35608-51). All measure 100mm length x 12mm diameter with a 3 foot cable. Calibration kit (WD-35607-69) contains four each of TDS ‘Singles’ calibration solution pouches (447?S - 1413?S - 2764?S - 15.0mS) - four rinse water pouches - one rinse bottle - and three sample bottles - all in a hard plastic carrying case with room for your meter and probe. Dimensions (L x W x H): 11.5 x 14 x 3 inches. A soft nylon carrying case with a Velcro belt loop (WD-35615-75) that is designed to protect your CON 11 meter while you take measurements. Optional 110V AC adapter (WD-35615-07) Optional 220V AC adapter (WD-35615-08) This Oakton CON 11 standard conductivity/TDS meter includes a meter - one epoxy body/stainless

Documents & Videos

The Oakton CON 11 Standard Conductivity and TDS Meter features a dual display that lets you see conductivity/TDS and temperature at a glance. The auto ranging feature spans across five ranges for fast response and the best resolution over a wide range. The meter has a built-in memory that stores up to 50 readings. The four-point conductivity calibration can be set to auto or manual and will calibrate one point per range for high +/- 1.0% full-scale accuracy. The Oakton CON 11 standard conductivity/TDS meter also features single or multi-point calibration for multi-range calibration of highest accuracy. The Oakton CON 11 standard conductivity/TDS meter has a selectable manual or automatic temperature compensation feature that provides great accuracy in any application. It also features an adjustable conductivity-to-TDS conversion factor from 0.4 to 1.0. The meter can be powered with either four 1.5V AAA batteries (included) for greater than 200 hours continuous use or an optional 9V - 500mA AC adapter for use in the field or at your benchtop. The Oakton CON 11 standard conductivity/TDS meter comes with a built-in stand for benchtop or long-term use. It also features a ready indicator which indicates when your measurement has stabilized - so you always record the best reading. The hold function freezes measurements for convenient reading and recording. An auto-off function turns the Oakton CON 11 standard conductivity/TDS meter off after 20 minutes of non-use to conserve batteries. The Oakton CON 11 standard conductivity/TDS meter is useful in a wide variety of applications. It is ideal for quick - accurate - routine testing checks of conductivity/TDS in labs and schools - as well as in water quality testing to assess hard water - untreated water - drinking water - incoming process water - and pool water. It is used in the industrial arena to check pollution control - metal finishing - cooling tower water - boiler water - brines - rinse tanks - ponds - re-circulating systems - and wastewater - and is also useful in the hydroponics and agricultural industries. Specifications: Conductivity range: 0.00 to 19.99µS - 0.0 to 199.9µS - 0 to 1999µS - 0.00 to 19.99mS - 0.00 to 199.9mS. Conductivity resolution: 0.01µS - 0.1µS - 1µS - 0.01mS - 0.1mS. Conductivity accuracy: +/-1% full scale. TDS range: 0.00 to 9.99ppm - 0.0 to 99.9ppm - 0 to 999ppm - 0.00 to 9.99ppt - 0.0 to 99.9ppt. TDS resolution: 0.01ppm - 0.1ppm - 1ppm - 0.01ppt - 0.1ppt. TDS accuracy: +/-1% full scale. Conductivity to TDS factor: adjustable from 0.4 to 1.0. Temperature compensation: automatic or manual from 0 to 100°C. Operating temperature: 0 to 50°C (32 to 122°F). Temperature coefficient: 0 to 10%/°C. Memory: up to 50 data sets. Power: four 1.5V AAA batteries (included) that give greater than 200 hours continuous use; optional 9V - 500mA AC adapter available. Dimensions (L x W x H): meter: 7.5 x 3.5 x 1.75 inches (19 x 9 x 4.5cm); boxed: 9.2 x 8.2 x 2.75 inches (23 x 23 x 7cm). Weight: meter: 1 lb (0.5 kg); boxed: 2 lb (0.9 kg). Accessories and replacement parts: Conductivity cells feature a built-in temperature sensor. Choose a cell with K = 0.1 for low-range measurements (epoxy body/platinum sensor; WD-35608-55); K = 1.0 for midrange measurements (epoxy body/stainless steel sensor; WD-35608-50); or K = 10 for high-range measurements (epoxy body/platinum sensor; WD-35608-51). All measure 100mm length x 12mm diameter with a 3 foot cable. Calibration kit (WD-35607-69) contains four each of TDS ‘Singles’ calibration solution pouches (447?S - 1413?S - 2764?S - 15.0mS) - four rinse water pouches - one rinse bottle - and three sample bottles - all in a hard plastic carrying case with room for your meter and probe. Dimensions (L x W x H): 11.5 x 14 x 3 inches. A soft nylon carrying case with a Velcro belt loop (WD-35615-75) that is designed to protect your CON 11 meter while you take measurements. Optional 110V AC adapter (WD-35615-07) Optional 220V AC adapter (WD-35615-08) This Oakton CON 11 standard conductivity/TDS meter includes a meter - one epoxy body/stainless

Ratings & Reviews

No reviews available

Be the first to Write a Review