  • Oakton® WD-35607-85 CON 110 Portable Conductivity/TDS Meter with Datalog Assist PC Software, WD-356

Oakton® WD-35607-85 CON 110 Portable Conductivity/TDS Meter with Datalog Assist PC Software, WD-35608-50 Conductivity Cell Probe & Accessories, Conductivity Range: 0 to 199900 Microsiemens/cm, TDS Range: 1 to 99900ppm, Temperature Dual Range: -10 to 110°C/14 to 230°F

  • Adjustable conductivity to- TDS factor from 0.4 to 1.0
  • Includes single- or multi-point calibration for quick multi-range calibration for highest accuracy, hold function, error messages, auto-off function, adjustable temperature coefficient
  • It reads conductivity from 0 to 199.9 mS across five ranges
  • RS-232/printer output download data to a computer or printer - ideal for GLP or HACCP data recording needs
  • Free Oakton PC datalog assist software on CD-ROM organizes data into format ready to import into popular spreadsheet programs
  • Manufacturer: Oakton Instruments
  • Manufacturer Part No: OAK-35607-85
(0) No Reviews yet
Item Number: OAK-WD-35607-85

Details

The Oakton CON 110 standard conductivity meter offers many calibration features. There is an automatic or manual five-point calibration in which the Oakton CON 110 standard conductivity meter can recall previous calibration data. Single or multi-point calibration is available to the Oakton CON 110 standard conductivity meter offers quick multi-range calibration resulting in the highest accuracy. The Oakton CON 110 standard conductivity meter reads conductivity from 0 to 199.9 ms across five ranges. There is a selectable automatic or manual temperature compensation feature. The Oakton CON 110 standard conductivity meter offers manual or auto-ranging for conductivity measurements; auto-ranging for TDS readings. The Oakton CON 110 standard conductivity meter's memory function stores and recalls 100 readings with corresponding temperature data. The Oakton CON 110 standard conductivity meter also includes a hold function - error messages - and an auto-off function. Oakton CON 110 standard conductivity meters can easily switch from conductivity to TDS readings and also have an adjustable conductivity-to-TDS factor from 0.4 to 1.0. There is an RS-232/printer output to download data to a computer or printer which is ideal for GLP or HACCP data recording needs. Oakton PC datalog assist software is also included. The Oakton CON 110 standard conductivity/TDS meter is useful in a wide variety of applications. It is ideal for quick - accurate - routine testing checks of conductivity/TDS in labs and schools - as well as in water quality testing to assess hard water - untreated water - drinking water - incoming process water - and pool water. It is used in the industrial arena to check pollution control - metal finishing - cooling tower water - boiler water - brines - rinse tanks - ponds - re-circulating systems - and wastewater - and is also useful in the hydroponics and agricultural industries. Specifications: Conductivity range: 0.00 to 19.99 µS - 0.0 to 199.9 µS - 0 to 1999 µS - 0.00 to 19.99 mS - 0.0 to 199.9 mS. Conductivity Resolution: 0.01 µS - 0.1 µS - 1 µS - 0.01 mS - 0.1 mS. TDS Range: 0.00 to 9.99 ppm - 10.0 to 99.9 ppm - 100 to 999 ppm - 1.00 to 9.99 ppt - 10.0 to 99.9 ppt - 100 to 200 ppt. TDSResolution: 0.01 ppm - 0.1 ppm - 1 ppm - 0.01 ppt - 0.1 ppt - 1 ppt. TDSAccuracy: +/- 1% full scale. Conductivity to TDS factor: Adjustable from 0.4 to 1.0 factor. Temperature compensation: automatic or manual (selectable) from 0 to 100°C. Operating temperature: 0 to 50°C. Temperature coefficient: adjustable from 0.00 to 10.00% per °C. Memory: up to 100 data sets. Power: four 1.5V AAA batteries (included) that give greater than 200 hours continuous use; optional 9V - 500mA AC adapter available. Dimensions (L x W x H): meter: 7.5 x 3.5 x 1.75 inches (19 x 9 x 4.5cm); boxed: 9.2 x 9.2 x 2.75 inches (23 x 23 x 7cm). Weight: meter: 1 lb (0.5 kg); boxed: 2 lb (0.9 kg). Accessories and replacement parts: Conductivity cells feature a built-in temperature sensor. Choose a cell with K = 0.1 for low-range measurements (epoxy body/platinum sensor; WD-35608-55); K = 1.0 for midrange measurements (epoxy body/stainless steel sensor; WD-35608-50); or K = 10 for high-range measurements (epoxy body/platinum sensor; WD-35608-51). All measure 100mm length x 12mm diameter with a 3 foot cable. Soft carrying case with belt loop (WD-35615-75). Protects meter while you take measurements––nylon with Velcro. Optional: WD-35615-07 AC adapter - 110 VAC. Optional: WD-35615-08 AC adapter - 220 VAC. WD-35622-00 Portable printer - 110 VAC - rechargeable.WD-35622-05 Portable printer - 220 VAC - rechargeable. WD-35615-09 Computer cable - 9-pin male to 9-pin female connects meter to your PC. WD-35622-59 Printer cable - 25-pin male to 9-pin male connects meter to your printer. Oakton #: WD-35607-85

Documents & Videos

The Oakton CON 110 standard conductivity meter offers many calibration features. There is an automatic or manual five-point calibration in which the Oakton CON 110 standard conductivity meter can recall previous calibration data. Single or multi-point calibration is available to the Oakton CON 110 standard conductivity meter offers quick multi-range calibration resulting in the highest accuracy. The Oakton CON 110 standard conductivity meter reads conductivity from 0 to 199.9 ms across five ranges. There is a selectable automatic or manual temperature compensation feature. The Oakton CON 110 standard conductivity meter offers manual or auto-ranging for conductivity measurements; auto-ranging for TDS readings. The Oakton CON 110 standard conductivity meter's memory function stores and recalls 100 readings with corresponding temperature data. The Oakton CON 110 standard conductivity meter also includes a hold function - error messages - and an auto-off function. Oakton CON 110 standard conductivity meters can easily switch from conductivity to TDS readings and also have an adjustable conductivity-to-TDS factor from 0.4 to 1.0. There is an RS-232/printer output to download data to a computer or printer which is ideal for GLP or HACCP data recording needs. Oakton PC datalog assist software is also included. The Oakton CON 110 standard conductivity/TDS meter is useful in a wide variety of applications. It is ideal for quick - accurate - routine testing checks of conductivity/TDS in labs and schools - as well as in water quality testing to assess hard water - untreated water - drinking water - incoming process water - and pool water. It is used in the industrial arena to check pollution control - metal finishing - cooling tower water - boiler water - brines - rinse tanks - ponds - re-circulating systems - and wastewater - and is also useful in the hydroponics and agricultural industries. Specifications: Conductivity range: 0.00 to 19.99 µS - 0.0 to 199.9 µS - 0 to 1999 µS - 0.00 to 19.99 mS - 0.0 to 199.9 mS. Conductivity Resolution: 0.01 µS - 0.1 µS - 1 µS - 0.01 mS - 0.1 mS. TDS Range: 0.00 to 9.99 ppm - 10.0 to 99.9 ppm - 100 to 999 ppm - 1.00 to 9.99 ppt - 10.0 to 99.9 ppt - 100 to 200 ppt. TDSResolution: 0.01 ppm - 0.1 ppm - 1 ppm - 0.01 ppt - 0.1 ppt - 1 ppt. TDSAccuracy: +/- 1% full scale. Conductivity to TDS factor: Adjustable from 0.4 to 1.0 factor. Temperature compensation: automatic or manual (selectable) from 0 to 100°C. Operating temperature: 0 to 50°C. Temperature coefficient: adjustable from 0.00 to 10.00% per °C. Memory: up to 100 data sets. Power: four 1.5V AAA batteries (included) that give greater than 200 hours continuous use; optional 9V - 500mA AC adapter available. Dimensions (L x W x H): meter: 7.5 x 3.5 x 1.75 inches (19 x 9 x 4.5cm); boxed: 9.2 x 9.2 x 2.75 inches (23 x 23 x 7cm). Weight: meter: 1 lb (0.5 kg); boxed: 2 lb (0.9 kg). Accessories and replacement parts: Conductivity cells feature a built-in temperature sensor. Choose a cell with K = 0.1 for low-range measurements (epoxy body/platinum sensor; WD-35608-55); K = 1.0 for midrange measurements (epoxy body/stainless steel sensor; WD-35608-50); or K = 10 for high-range measurements (epoxy body/platinum sensor; WD-35608-51). All measure 100mm length x 12mm diameter with a 3 foot cable. Soft carrying case with belt loop (WD-35615-75). Protects meter while you take measurements––nylon with Velcro. Optional: WD-35615-07 AC adapter - 110 VAC. Optional: WD-35615-08 AC adapter - 220 VAC. WD-35622-00 Portable printer - 110 VAC - rechargeable.WD-35622-05 Portable printer - 220 VAC - rechargeable. WD-35615-09 Computer cable - 9-pin male to 9-pin female connects meter to your PC. WD-35622-59 Printer cable - 25-pin male to 9-pin male connects meter to your printer. Oakton #: WD-35607-85

Ratings & Reviews

No reviews available

Be the first to Write a Review