• Home
  • Oakton® WD-53400-05 Eutech Instruments® DO 1000 Dissolved Oxygen Digital Controller with Dual Setpo

Oakton® WD-53400-05 Eutech Instruments® DO 1000 Dissolved Oxygen Digital Controller with Dual Setpoint, On/Off & Proportional Controls, Electrical: 220V

  • Selectable on/off or proportional control
  • Dual display shows dissolved oxygen readings (in mg/L, ppm, or percent saturation) plus temperature
  • Two set point, two SPDT relay operation with separate alarm relay
  • 0 to 2000 second time delay on all relays-minimizes false alarms; 50 Hz power; measures 3-13/16 inch width by 3-13/16 inch height by 6-15/16 inch depth (1/4 DIN)
  • Manufacturer Part No: EW-53400-05
(0) No Reviews yet

PLEASE NOTE: Product images and descriptions may not exactly represent the product. Prior to making your purchase, please confirm that the manufacturer part number shown above matches the product you seek. Returns are not allowed for such differences if the correct manufacturer part number is shipped.

Item Number: OAK-WD-53400-05
This item is discontinued. Please contact customer service at 512.836.1667 if you would like assistance finding an alternative item.

Details

Use this controller for precise dissolved oxygen (DO) control of your wastewater or aquaculture process. Select from on/off - proportional pulse length - or proportional pulse frequency control types. Two set point - two SPDT relay operation lets you set low/low - low/high - high/low - or high/high control. Separately adjustable hysteresis bands prevent rapid contact switching near the set points. Independent 100 percent and 0 percent saturation calibrations ensure high accuracy over the entire range. Key in the salinity of your solution and the barometric pressure-controller automatically corrects the readings to these offset values. Scalable 0-20/4-20 mA recorder/transmitter output lets you make hard copy records of your data. Nonvolatile memory maintains setup parameters even when power is shut off. Two-level password protects all settings. Specifications: proportional pulse length - pulse frequency - or on/off (user selectable) control type. 0.00 mg/l (ppm) to 20.00 mg/l (ppm) range. Percent O2 saturation range is 0.0 percent to 200 percent. Temperature range is 0 to 50 Degree C. 0.01mg/l (ppm) resolution. Percent O2 saturation resolution is 0.01 percent. Temperature range is 0.1 Degree C. +/-1.5 percent full scale mg/l (ppm) accuracy. Percent O2 saturation accuracy is +/-1.5 percent full scale. Temperature is +/-0.5 Degree C. Manual input from 0.0 to 50.0 ppt - automatic offset of measurements salinity compensation. Automatic - 0 to 50 Degree C or manual from -9.9 to 125 Degree C temperature compensation. Manual input from 555 to 808mm Hg; automatic offset of measurements pressure compensation. Control output relay is 2 SPDT relays - 6 A at 110 VAC - 250 VAC max. Control output current Isolated 0-20/4-20 mA - 600 ohm max load - programmable boundaries. Control output alarm 1 SPDT relay - 6 A at 110 VAC - 250 VAC max. Dual display of DO reading plus temperature. Pulse length (0.5 to 20 sec) or pulse frequency (60 to 120 pulses per min). Oakton #: WD-53400-05

Documents & Videos

Use this controller for precise dissolved oxygen (DO) control of your wastewater or aquaculture process. Select from on/off - proportional pulse length - or proportional pulse frequency control types. Two set point - two SPDT relay operation lets you set low/low - low/high - high/low - or high/high control. Separately adjustable hysteresis bands prevent rapid contact switching near the set points. Independent 100 percent and 0 percent saturation calibrations ensure high accuracy over the entire range. Key in the salinity of your solution and the barometric pressure-controller automatically corrects the readings to these offset values. Scalable 0-20/4-20 mA recorder/transmitter output lets you make hard copy records of your data. Nonvolatile memory maintains setup parameters even when power is shut off. Two-level password protects all settings. Specifications: proportional pulse length - pulse frequency - or on/off (user selectable) control type. 0.00 mg/l (ppm) to 20.00 mg/l (ppm) range. Percent O2 saturation range is 0.0 percent to 200 percent. Temperature range is 0 to 50 Degree C. 0.01mg/l (ppm) resolution. Percent O2 saturation resolution is 0.01 percent. Temperature range is 0.1 Degree C. +/-1.5 percent full scale mg/l (ppm) accuracy. Percent O2 saturation accuracy is +/-1.5 percent full scale. Temperature is +/-0.5 Degree C. Manual input from 0.0 to 50.0 ppt - automatic offset of measurements salinity compensation. Automatic - 0 to 50 Degree C or manual from -9.9 to 125 Degree C temperature compensation. Manual input from 555 to 808mm Hg; automatic offset of measurements pressure compensation. Control output relay is 2 SPDT relays - 6 A at 110 VAC - 250 VAC max. Control output current Isolated 0-20/4-20 mA - 600 ohm max load - programmable boundaries. Control output alarm 1 SPDT relay - 6 A at 110 VAC - 250 VAC max. Dual display of DO reading plus temperature. Pulse length (0.5 to 20 sec) or pulse frequency (60 to 120 pulses per min). Oakton #: WD-53400-05

Ratings & Reviews

No reviews available

Be the first to Write a Review