HANNA HI1207 Replacement pH Electrode for use with HI98103 Checker® pH Tester, Body: Plastic, Electrolyte: Gel, Connection: Screw Top
Item Number:HAN-HI1207
Manufacturer Part No:HI1207
Manufacturer:Hanna Instruments
Details
Accurate and reproducible pH measurements depend on proper attention to calibration. When it is necessary for the user to measure pH values outside the standard buffers range. The HI 120 benchtop pH meter can offer help in these situations. Equipped with automatic calibration of up to 5 points, these meters allow the user to tailor the calibration window to the appropriate range. Select from among the 7 factory stored values and up to 2 customized values, for specific applications. With Hanna's featured Calibration Check™, calibration information and probe condition are readily observed directly on the display screen, with a %-value indicating the electrode condition and response consistencies. These meters record and store significant data capture including time, date links to readouts and are compliant with GLP. Hanna #: HI 120.• • SPECIFICATIONS • • • Range (pH): -2.00 to 16.00 pH; -2.000 to 16.000 pH • Range (mV): ±999.9 mV; ±2000 mV • Range (Temperature): -20.0 to 120.0°C • Resolution (pH): 0.01 pH / 0.001 pH • Resolution (mV): 0.1 mV / 1 mV • Resolution (Temperature): 0.1°C • Accuracy (pH): ±0.01 pH / ±0.002 pH • Accuracy (mV): ±0.2 mV (±699.9 mV) / ±0.5 mV (±999.9 mV) / ±1 mV (±2000 mV) • Accuracy (Temperature): ±0.4°C • BNC Inputs: 1 for pH electrode • Calibration Check: Status of electrode condition and response time status of the buffer solutions during calibration • Relative mV Offset Range: ±2000 mV • pH Calibration: Automatic, up to 5 points with 7 memorized values (1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) + 2 custom buffers • Temperature Compensation: Automatic or manual, -20.0 to 120°C (-4 to 248°F) • pH Electrode: HI 1131P, glass body, refillable, BNC + pin connectors, 1 m cable (included) • Temperature Probe: HI 7662-T with 1 m (3.3') cable (included) Input Impedance: 1012 • Log-On-Demand: 50 samples • Automatic Data Logging: 1000 samples • PC Connection: RS232 serial port, optoisolated • Power Supply: 12 Vdc adapter (included) • Environment: 0 to 50°C (32 to 122°F); RH max 95% • Dimensions: 280 x 203 x 84 mm (11.0 x 8.0 x 3.3") • Weight: 1.8 kg (4.0 lb.)
Documents & Videos
Accurate and reproducible pH measurements depend on proper attention to calibration. When it is necessary for the user to measure pH values outside the standard buffers range. The HI 120 benchtop pH meter can offer help in these situations. Equipped with automatic calibration of up to 5 points, these meters allow the user to tailor the calibration window to the appropriate range. Select from among the 7 factory stored values and up to 2 customized values, for specific applications. With Hanna's featured Calibration Check™, calibration information and probe condition are readily observed directly on the display screen, with a %-value indicating the electrode condition and response consistencies. These meters record and store significant data capture including time, date links to readouts and are compliant with GLP. Hanna #: HI 120.• • SPECIFICATIONS • • • Range (pH): -2.00 to 16.00 pH; -2.000 to 16.000 pH • Range (mV): ±999.9 mV; ±2000 mV • Range (Temperature): -20.0 to 120.0°C • Resolution (pH): 0.01 pH / 0.001 pH • Resolution (mV): 0.1 mV / 1 mV • Resolution (Temperature): 0.1°C • Accuracy (pH): ±0.01 pH / ±0.002 pH • Accuracy (mV): ±0.2 mV (±699.9 mV) / ±0.5 mV (±999.9 mV) / ±1 mV (±2000 mV) • Accuracy (Temperature): ±0.4°C • BNC Inputs: 1 for pH electrode • Calibration Check: Status of electrode condition and response time status of the buffer solutions during calibration • Relative mV Offset Range: ±2000 mV • pH Calibration: Automatic, up to 5 points with 7 memorized values (1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) + 2 custom buffers • Temperature Compensation: Automatic or manual, -20.0 to 120°C (-4 to 248°F) • pH Electrode: HI 1131P, glass body, refillable, BNC + pin connectors, 1 m cable (included) • Temperature Probe: HI 7662-T with 1 m (3.3') cable (included) Input Impedance: 1012 • Log-On-Demand: 50 samples • Automatic Data Logging: 1000 samples • PC Connection: RS232 serial port, optoisolated • Power Supply: 12 Vdc adapter (included) • Environment: 0 to 50°C (32 to 122°F); RH max 95% • Dimensions: 280 x 203 x 84 mm (11.0 x 8.0 x 3.3") • Weight: 1.8 kg (4.0 lb.)