JT Baker® 4208-F9 Urea, USP Grade, 50Kg Flowmor Container
Item Number:JTB-4208-F9
Manufacturer Part No:JT-4208-F9
Manufacturer:Avantor
Units:50Kg Flowmor Drum
Details
- 50Kg Flowmor Drum
Product Specifications
TEST | SPECIFICATION |
GMP Manufactured Product | |
Meets U.S.P Requirements | |
CAUTION: For Manufacturing, processing or repackaging | |
Bulk Pharmaceutical Chemical | |
USP - Assay (NH₂CONH₂) | 98.0 - 102.0 % |
USP - Alcohol Insoluble Matter | <= 0.04 % |
USP - Heavy Metals (as Pb) | <= 0.002 % |
USP - Identification A | Passes Test |
USP - Identification B | Passes Test |
USP - Organic impurities: Urea related compound A | <= 0.1 % |
USP - Organic impurities: Any individual unspecified impurity | <= 0.1 % |
USP - Organic impurities: Total impurities | <= 2.0 % |
USP - Residue on Ignition | <= 0.1 % |
Absorbance of a 5M Solution - 260 nm | <= 0.050 |
Absorbance of a 5M Solution - 280 nm | <= 0.030 |
Assay (NH₂CONH₂) | >= 99.5 % |
Biuret | <= 0.01 |
Conductivity of 8.5M Solution at 25°C, (µmho/cm) | <= 45 |
Cyanate (CNO) | None Detected |
Endotoxin Concentration (EU/g) | <= 2.5 |
Insoluble Matter | <= 0.01 % |
Water (H₂O) | <= 0.5 % |
Chloride (Cl) | <= 1 ppm |
Trace Impurities - Copper (Cu) | <= 1 ppm |
Trace Impurities - Iron (Fe) | <= 1 ppm |
Trace Impurities - Lead (Pb) | <= 5.0 ppm |
Ultrapure Bioreagent Specifications | |
No Class 1,2,3 or other solvents are used or produced in the manufacturing or purification of the product. | |
Manufactured exclusively for Avantor Performance Materials, Inc., by BioSpectra, Inc., Stroudsburg, PA |
Documents & Videos
Product Specifications
TEST | SPECIFICATION |
GMP Manufactured Product | |
Meets U.S.P Requirements | |
CAUTION: For Manufacturing, processing or repackaging | |
Bulk Pharmaceutical Chemical | |
USP - Assay (NH₂CONH₂) | 98.0 - 102.0 % |
USP - Alcohol Insoluble Matter | <= 0.04 % |
USP - Heavy Metals (as Pb) | <= 0.002 % |
USP - Identification A | Passes Test |
USP - Identification B | Passes Test |
USP - Organic impurities: Urea related compound A | <= 0.1 % |
USP - Organic impurities: Any individual unspecified impurity | <= 0.1 % |
USP - Organic impurities: Total impurities | <= 2.0 % |
USP - Residue on Ignition | <= 0.1 % |
Absorbance of a 5M Solution - 260 nm | <= 0.050 |
Absorbance of a 5M Solution - 280 nm | <= 0.030 |
Assay (NH₂CONH₂) | >= 99.5 % |
Biuret | <= 0.01 |
Conductivity of 8.5M Solution at 25°C, (µmho/cm) | <= 45 |
Cyanate (CNO) | None Detected |
Endotoxin Concentration (EU/g) | <= 2.5 |
Insoluble Matter | <= 0.01 % |
Water (H₂O) | <= 0.5 % |
Chloride (Cl) | <= 1 ppm |
Trace Impurities - Copper (Cu) | <= 1 ppm |
Trace Impurities - Iron (Fe) | <= 1 ppm |
Trace Impurities - Lead (Pb) | <= 5.0 ppm |
Ultrapure Bioreagent Specifications | |
No Class 1,2,3 or other solvents are used or produced in the manufacturing or purification of the product. | |
Manufactured exclusively for Avantor Performance Materials, Inc., by BioSpectra, Inc., Stroudsburg, PA |