Macron™ H487-06 Hexanes (95% n-Hexane), UltimAR Analytical Reagent Grade for Liquid Chromatography & UV Spectrophotometry, 1L Glass Bottle (Case of 6)

Notice: Hazardous chemicals and products will incur additional Hazmat Fees and/or mandatory shipment via LTL Motor Freight
Item Number:MAL-H487-06
Manufacturer Part No:MK-H487-06
Manufacturer:Avantor
Units:Case of 6 x 1L Glass Bottles

Details

  • Case of 6 x 1L Glass Bottles

Product Specifications

TESTSPECIFICATION
For Laboratory,Research,or Manufacturing Use
ACS - Assay (sum of 5 isomers, total hexanes<(>,<)> plus>= 99.5 %
methylcyclopentane)(by GC)>= 99.5 %
ACS - Assay (as n-hexane) (by GC, corrected for water)>= 95.0 %
ACS - Color (APHA)<= 10
ACS - Residue after Evaporation<= 0.0001 %
ACS - Sulfur Compounds (as S)<= 0.005 %
ACS - ThiophenePasses Test
ACS - Water (H₂O)(by Karl Fischer titrn)<= 0.01 %
ACS - Water-Soluble Titrable Acid (meq/g)<= 0.0003
Ultraviolet Absorbance (1.00-cm cell vs. water) - 195 nm<= 1.00
Ultraviolet Absorbance (1.00-cm cell vs. water) - 210 nm<= 0.20
Ultraviolet Absorbance (1.00-cm cell vs. water) - 220 nm<= 0.07
Ultraviolet Absorbance (1.00-cm cell vs. water) - 230 nm<= 0.05
Ultraviolet Absorbance (1.00-cm cell vs. water) - 240 nm<= 0.04
Ultraviolet Absorbance (1.00-cm cell vs. water) - 250 nm<= 0.02
Ultraviolet Absorbance (1.00-cm cell vs. water) - 254 nm<= 0.005
Ultraviolet Absorbance (1.00-cm cell vs. water) - 280 - 400 nm<= 0.005
Fluorescence Trace Impurities, measured as Quinine Base - at 450 nm Emission<= 0.3 ppb
Fluorescence Trace Impurities, measured as Quinine Base - at Emission Maximum for Impurities<= 1.0 ppb
ECD Sensitive Impurities (as Heptachl or Epoxide) Single Peak (ng/L)<= 10 ppb
FID Sensitive Impurities (as 2-Octano l) Single Peak (µg/L)<= 5 ppb
FID - Sum of the Peaks (µg/L)<= 10
ECD-Sensitive Impurities (as Ethylene Dibromide) - Single Impurity Peak (ng/mL)<= 5
Neat Solvent Front Characterization - Largest Peak, 0-0.4 x RT (ng/mL)
Filtered through a 0.2 micron filter.
Packaged under Nitrogen

Documents & Videos

Product Specifications

TESTSPECIFICATION
For Laboratory,Research,or Manufacturing Use
ACS - Assay (sum of 5 isomers, total hexanes<(>,<)> plus>= 99.5 %
methylcyclopentane)(by GC)>= 99.5 %
ACS - Assay (as n-hexane) (by GC, corrected for water)>= 95.0 %
ACS - Color (APHA)<= 10
ACS - Residue after Evaporation<= 0.0001 %
ACS - Sulfur Compounds (as S)<= 0.005 %
ACS - ThiophenePasses Test
ACS - Water (H₂O)(by Karl Fischer titrn)<= 0.01 %
ACS - Water-Soluble Titrable Acid (meq/g)<= 0.0003
Ultraviolet Absorbance (1.00-cm cell vs. water) - 195 nm<= 1.00
Ultraviolet Absorbance (1.00-cm cell vs. water) - 210 nm<= 0.20
Ultraviolet Absorbance (1.00-cm cell vs. water) - 220 nm<= 0.07
Ultraviolet Absorbance (1.00-cm cell vs. water) - 230 nm<= 0.05
Ultraviolet Absorbance (1.00-cm cell vs. water) - 240 nm<= 0.04
Ultraviolet Absorbance (1.00-cm cell vs. water) - 250 nm<= 0.02
Ultraviolet Absorbance (1.00-cm cell vs. water) - 254 nm<= 0.005
Ultraviolet Absorbance (1.00-cm cell vs. water) - 280 - 400 nm<= 0.005
Fluorescence Trace Impurities, measured as Quinine Base - at 450 nm Emission<= 0.3 ppb
Fluorescence Trace Impurities, measured as Quinine Base - at Emission Maximum for Impurities<= 1.0 ppb
ECD Sensitive Impurities (as Heptachl or Epoxide) Single Peak (ng/L)<= 10 ppb
FID Sensitive Impurities (as 2-Octano l) Single Peak (µg/L)<= 5 ppb
FID - Sum of the Peaks (µg/L)<= 10
ECD-Sensitive Impurities (as Ethylene Dibromide) - Single Impurity Peak (ng/mL)<= 5
Neat Solvent Front Characterization - Largest Peak, 0-0.4 x RT (ng/mL)
Filtered through a 0.2 micron filter.
Packaged under Nitrogen