MilliporeSigma UFC501096 Amicon® Ultra-0.5 Centrifugal Filter Concentrator with Ultracel® 10 Regenerated Cellulose Membrane, NMWL: 10,000, Process Volume: 0.5mL,Non-Sterile (Pack of 96)

Item Number:MIL-UFC501096
Manufacturer Part No:UFC501096
Manufacturer:MilliporeSigma Filtration
Units:Pack of 96

Details

  • Designed for cencentration of biological samples containing nucleic acids, antigens, enzymes, antibodies or microorganisms
  • Key applications include: Protein Purification, Western Blotting & Protein Extraction
  • Use with fixed-angle microcentrifuge rotors. Max RCF: 14,000 x g for Concentration Spin; 1,000 x g for Reverse Spin.
  • Filter Membrane: Ultracel-10 Regenerated Cellulose; Filtration Area: 1cm2
  • Nominal Molecular Weight Limit (NMWL): 10 kDa; Concentrate 0.5mL samples down to 15µL final concentrated sample
  • Pack of 96
The Millipore Amicon® Ultra 0.5mL centrifugal filter device is supplied with two microcentrifuge tubes. During operation, one microcentrifuge tube is used to collect filtrate; the other tube is to recover the concentrated sample. These centrifugal devices concentrate 0.5mL samples down to 15µL with a concentration factor of anywhere from 25x to 30x. They provide a high sample recovery rate of 90% or better from the beginning sample solution. Process samples quickly – normally from 10 to 30-minutes. Amicon® Ultra centrifugal filters are also ideal for reverse spin methods which provide very consistent recovery results. Recommended for use with fixed-angle microcentrifuge rotors. Max RCF: 14,000 x g for Concentration Spin; 1,000 x g for Reverse Spin. Filter Device O.D. x Length: 9.4 x 29.6mm. Centrifuge Tube O.D. x Length: 10.8 x 43mm. Applications Include: 1) Desalting and buffer exchange. 2) Macromolecular component purification of tissue culture samples, cell lysates, protein removal prior to HPLC analysis, primer or linker removal and labels from reaction mixes. 3) Biological sample concentration with nucleic acids, enzymes antibodies, antigens or microorganisms.

Documents & Videos

The Millipore Amicon® Ultra 0.5mL centrifugal filter device is supplied with two microcentrifuge tubes. During operation, one microcentrifuge tube is used to collect filtrate; the other tube is to recover the concentrated sample. These centrifugal devices concentrate 0.5mL samples down to 15µL with a concentration factor of anywhere from 25x to 30x. They provide a high sample recovery rate of 90% or better from the beginning sample solution. Process samples quickly – normally from 10 to 30-minutes. Amicon® Ultra centrifugal filters are also ideal for reverse spin methods which provide very consistent recovery results. Recommended for use with fixed-angle microcentrifuge rotors. Max RCF: 14,000 x g for Concentration Spin; 1,000 x g for Reverse Spin. Filter Device O.D. x Length: 9.4 x 29.6mm. Centrifuge Tube O.D. x Length: 10.8 x 43mm. Applications Include: 1) Desalting and buffer exchange. 2) Macromolecular component purification of tissue culture samples, cell lysates, protein removal prior to HPLC analysis, primer or linker removal and labels from reaction mixes. 3) Biological sample concentration with nucleic acids, enzymes antibodies, antigens or microorganisms.