Thermo Scientific Orion STARA2230 Orion Star™ A223 Portable Dissolved Oxygen Meter Only, Parameters: RDO/Dissolved Oxygen/Temp

  • Thermo Scientific Orion Star A223 RDO/Dissolved Oxygen Portable meter; portable, waterproof and protected to take anywhere with a IP67-rated housing
  • Large, backlit graphic LCD display shows dissolved oxygen in percent saturation or concentration with temperature and electrode status, time, date and calibration points
  • Accepts and automatically recognizes Orion polarographic and RDO optical/ luminescence-based probes; AUTO-READ™ locks in stable reading on screen and ready indicator alerts when readings are stable
  • Calibrate using water-saturated air, air-saturated water, a Winkler titration or zero point calibration; non-volatile memory holds up to 1000 data points with time and date stamp
  • Four AA batteries (included) provide over 800 hours of operation or purchase the universal power adapter (sold separately) to use AC power; three year meter replacement warranty
  • Sold individually
  • Manufacturer Part No: ORI-STARA2230
(0) No Reviews yet

PLEASE NOTE: Product images and descriptions may not exactly represent the product. Prior to making your purchase, please confirm that the manufacturer part number shown above matches the product you seek. Returns are not allowed for such differences if the correct manufacturer part number is shipped.

Item Number: ORI-STARA2230
$986.86

Sold in: Eaches

UnitMSRPYour PriceStock StatusQty
Each1,040.00986.86Lead Time

New

Details

This Thermo Scientific Orion Star A223 RDO/Dissolved Oxygen Portable Meter makes necessary testing easier. Its durability and dependability make it a great choice for samples every day, anywhere. The large, backlit graphic LCD display shows dissolved oxygen in percent saturation or concentration with temperature and electrode status, time, date and calibration points. Anyone can use this meter with its plain language screen prompts, soft keys that update for easy selection and a multilanguage interface that supports English, Spanish, French, Italian, German and Chinese. No need to worry about DO probe compatibility – the meter accepts and automatically recognizes Orion polarographic and RDO optical/ luminescence-based probes. Accurate results are easy with automatic temperature, manual salinity and automatic/ manual barometric pressure compensation. The AUTO-READ™ locks in the stable reading on your screen and ready indicator alerts when readings are stable. Calibrate using water-saturated air, air-saturated water, a Winkler titration or zero point calibration. The non-volatile memory holds up to 1000 data points with time and date stamp. Easily transfer data and keep meter software up-to-date with the USB and RS232 ports and complimentary data analysis software. Four AA batteries (included) provide over 800 hours of operation or purchase the universal power adapter (sold separately) to use AC power. Perfectly portable, waterproof and protected to take anywhere with a IP67-rated housing. Three year meter replacement warranty. Certifications: CE, TUV, FCC Class A limits. Temperature Mode Range: -5° to 105°C (23° to 221°F). Temperature Mode Resolution: 0.1 (0.1). Temperature Mode Relative Accuracy: ±0.1. DO Mode Concentration Range: Polarographic--0 to 90mg/L; RDO optical--0 to 50mg/L. DO Mode Concentration Resolution: 0.01, 0.1. DO Mode Relative Accuracy: Polarographic--±0.2mg/L; ±2%; RDO optical--±0.1mg/L up to 8mg/L, ±0.2mg/L up to 20mg/L, 10% of reading beyond; ±2%. DO Mode % Saturation Range: Polarographic--0 to 600; RDO optical--0 to 500. DO Mode % Saturation Resolution: 0.1, 1. DO Mode Salinity Factor: 0 to 45 ppt, manual. DO Mode Calibration: Water-saturated air, air-saturated water, manual (Winkler) and zero point. Inputs: 8-pin mini-DIN. Sensor Types: Polarographic or RDO (optical/luminesce-based) DO. Data Management: 1000 points with date/time stamp. Output: RS-232, USB. Display: Graphic LCD; simultaneous display of measurement, temperature, date/time, and more. Power Supply: Four "AA" batteries or optional universal AC line voltage. Environmental Operating Conditions Relative Humidity: 5 to 85% noncondensing. Thermo Scientific Orion #: STARA2230.

Documents & Videos

This Thermo Scientific Orion Star A223 RDO/Dissolved Oxygen Portable Meter makes necessary testing easier. Its durability and dependability make it a great choice for samples every day, anywhere. The large, backlit graphic LCD display shows dissolved oxygen in percent saturation or concentration with temperature and electrode status, time, date and calibration points. Anyone can use this meter with its plain language screen prompts, soft keys that update for easy selection and a multilanguage interface that supports English, Spanish, French, Italian, German and Chinese. No need to worry about DO probe compatibility – the meter accepts and automatically recognizes Orion polarographic and RDO optical/ luminescence-based probes. Accurate results are easy with automatic temperature, manual salinity and automatic/ manual barometric pressure compensation. The AUTO-READ™ locks in the stable reading on your screen and ready indicator alerts when readings are stable. Calibrate using water-saturated air, air-saturated water, a Winkler titration or zero point calibration. The non-volatile memory holds up to 1000 data points with time and date stamp. Easily transfer data and keep meter software up-to-date with the USB and RS232 ports and complimentary data analysis software. Four AA batteries (included) provide over 800 hours of operation or purchase the universal power adapter (sold separately) to use AC power. Perfectly portable, waterproof and protected to take anywhere with a IP67-rated housing. Three year meter replacement warranty. Certifications: CE, TUV, FCC Class A limits. Temperature Mode Range: -5° to 105°C (23° to 221°F). Temperature Mode Resolution: 0.1 (0.1). Temperature Mode Relative Accuracy: ±0.1. DO Mode Concentration Range: Polarographic--0 to 90mg/L; RDO optical--0 to 50mg/L. DO Mode Concentration Resolution: 0.01, 0.1. DO Mode Relative Accuracy: Polarographic--±0.2mg/L; ±2%; RDO optical--±0.1mg/L up to 8mg/L, ±0.2mg/L up to 20mg/L, 10% of reading beyond; ±2%. DO Mode % Saturation Range: Polarographic--0 to 600; RDO optical--0 to 500. DO Mode % Saturation Resolution: 0.1, 1. DO Mode Salinity Factor: 0 to 45 ppt, manual. DO Mode Calibration: Water-saturated air, air-saturated water, manual (Winkler) and zero point. Inputs: 8-pin mini-DIN. Sensor Types: Polarographic or RDO (optical/luminesce-based) DO. Data Management: 1000 points with date/time stamp. Output: RS-232, USB. Display: Graphic LCD; simultaneous display of measurement, temperature, date/time, and more. Power Supply: Four "AA" batteries or optional universal AC line voltage. Environmental Operating Conditions Relative Humidity: 5 to 85% noncondensing. Thermo Scientific Orion #: STARA2230.

Ratings & Reviews

No reviews available

Be the first to Write a Review