The JT Baker Acetonitrile 9017-03, BAKER ANALYZED HPLC ULTRA Gradient Solvent, 4L Glass Bottle is available at Capitol Scientific for your laboratory needs.

Notice: Hazardous chemicals and products will incur additional Hazmat Fees and/or mandatory shipment via LTL Motor Freight
The JT Baker Acetonitrile 9017-03, BAKER ANALYZED HPLC ULTRA Gradient Solvent, 4L Glass Bottle is available at Capitol Scientific for your laboratory needs.
Item Number:JTB-9017-03
Manufacturer Part No:JT-9017-03
Manufacturer:Avantor
Units:Case of 4 x 4L Glass Bottles

Details

  • Case of 4 x 4L Glass Bottles

Product Specifications

TESTSPECIFICATION
For Laboratory,Research,or Manufacturing Use
Ultraviolet Absorbance (1.00-cm cell vs. water) - 400-254 nm<= 0.005
Ultraviolet Absorbance (1.00-cm cell vs. water) - 220 nm<= 0.01
Ultraviolet Absorbance (1.00-cm cell vs. water) - 200 nm<= 0.05
Ultraviolet Absorbance (1.00-cm cell vs. water) - UV Cut-off, nm<= 190
Gradient Elution Test (a.u.) - 254 nm<= 0.0005
Gradient Elution Test (a.u.) - 210 nm<= 0.002
Density (g/mL) at 25°C0.775 - 0.780
Fluorescence Trace Impurities, measured as Quinine Base - at 450 nm Emission<= 0.3 ppb
Fluorescence Trace Impurities, measured as Quinine Base - at Emission Maximum for Impurities<= 1.0 ppb
Assay (CH₃CN) (by GC)>= 99.9 %
AppearancePasses Test
Color (APHA)<= 10
Fluorescence Trace Impurities, measured as Quinine Base - Fluorescence detection (PAH)<= 0.5 ppb
Residue after Evaporation<= 1.0 ppm
Titrable Acid (µeq/g)<= 0.8
Titrable Base (µeq/g)<= 0.6
Water (by KF, coulometric)<= 100 ppm
Carbonyl Compounds (as Acetone)<= 25.0 ppb
Filtered through a 0.2 micron filter.

Documents & Videos

Product Specifications

TESTSPECIFICATION
For Laboratory,Research,or Manufacturing Use
Ultraviolet Absorbance (1.00-cm cell vs. water) - 400-254 nm<= 0.005
Ultraviolet Absorbance (1.00-cm cell vs. water) - 220 nm<= 0.01
Ultraviolet Absorbance (1.00-cm cell vs. water) - 200 nm<= 0.05
Ultraviolet Absorbance (1.00-cm cell vs. water) - UV Cut-off, nm<= 190
Gradient Elution Test (a.u.) - 254 nm<= 0.0005
Gradient Elution Test (a.u.) - 210 nm<= 0.002
Density (g/mL) at 25°C0.775 - 0.780
Fluorescence Trace Impurities, measured as Quinine Base - at 450 nm Emission<= 0.3 ppb
Fluorescence Trace Impurities, measured as Quinine Base - at Emission Maximum for Impurities<= 1.0 ppb
Assay (CH₃CN) (by GC)>= 99.9 %
AppearancePasses Test
Color (APHA)<= 10
Fluorescence Trace Impurities, measured as Quinine Base - Fluorescence detection (PAH)<= 0.5 ppb
Residue after Evaporation<= 1.0 ppm
Titrable Acid (µeq/g)<= 0.8
Titrable Base (µeq/g)<= 0.6
Water (by KF, coulometric)<= 100 ppm
Carbonyl Compounds (as Acetone)<= 25.0 ppb
Filtered through a 0.2 micron filter.