Thermo Scientific Orion® 8302BNUMD Ross™ Ultra Triode™ Combination pH/ATC Electrode, Body: Glass, pH Range: pH 0 to 14, Temperature Range: 0 to 100°C, Connection: Mini DIN

  • Glass fiber junction
  • Double junction design prevents sample contamination
  • Filling solution can be changed when potassium or chloride in the sample is not desired
  • Electrode drift is less than 0.002 pH per day, so restandardization is minimized
  • Stable to 0.01 pH within 30 seconds in 6.86 between 25°C and 75°C
  • Per each
  • Manufacturer Part No: ORI-8302BNUMD
(0) No Reviews yet

PLEASE NOTE: Product images and descriptions may not exactly represent the product. Prior to making your purchase, please confirm that the manufacturer part number shown above matches the product you seek. Returns are not allowed for such differences if the correct manufacturer part number is shipped.

Item Number: ORI-8302BNUMD
$751.53

Sold in: Eaches

UnitMSRPYour PriceStock StatusQty
Each792.00751.53Lead Time

New

Details

Thermo Scientific Orion® ROSS Ultra® Triode„¢ Combination Electrode 0 to 14 pH. For use with Thermo Scientific Orion® Star meters. Provides more flexibility and enhanced features. All ROSS® electrodes are double junction electrodes and can be used in samples that contain TRIS, sulfides and proteins since they do not contain silver or mercury. The ROSS Ultra® Triode„¢ incorporates the patented ROSS® internal reference system that provides superior measurement stability, faster response, greater accuracy and more reproducible results than conventional electrodes. Combination of pH/Automatic Temperature Compensation. Glass fiber junction. Double junction design prevents sample contamination. Filling solution can be changed when potassium or chloride in the sample is not desired. Electrode drift is less than 0.002 pH per day, so restandardization is minimized. Stable to 0.01 pH within 30 seconds in 6.86 between 25°C and 75°C. Material: Chemical resistant glass body. Connector: 8 pin mini DIN. pH range: 0 to 14. Temperature range: 0 to 100°C. Dimensions: 120 x 12mm. pH precision: 0.01. pH accuracy: 0.03 pH for buffers using automatic temperature compensation. Temperature accuracy: 1.0°C. Isopotential point: 7. Fill solution: 3M KCl. Per each. Thermo Scientific Orion® #: 8302BNUMD.

Documents & Videos

Thermo Scientific Orion® ROSS Ultra® Triode„¢ Combination Electrode 0 to 14 pH. For use with Thermo Scientific Orion® Star meters. Provides more flexibility and enhanced features. All ROSS® electrodes are double junction electrodes and can be used in samples that contain TRIS, sulfides and proteins since they do not contain silver or mercury. The ROSS Ultra® Triode„¢ incorporates the patented ROSS® internal reference system that provides superior measurement stability, faster response, greater accuracy and more reproducible results than conventional electrodes. Combination of pH/Automatic Temperature Compensation. Glass fiber junction. Double junction design prevents sample contamination. Filling solution can be changed when potassium or chloride in the sample is not desired. Electrode drift is less than 0.002 pH per day, so restandardization is minimized. Stable to 0.01 pH within 30 seconds in 6.86 between 25°C and 75°C. Material: Chemical resistant glass body. Connector: 8 pin mini DIN. pH range: 0 to 14. Temperature range: 0 to 100°C. Dimensions: 120 x 12mm. pH precision: 0.01. pH accuracy: 0.03 pH for buffers using automatic temperature compensation. Temperature accuracy: 1.0°C. Isopotential point: 7. Fill solution: 3M KCl. Per each. Thermo Scientific Orion® #: 8302BNUMD.

Ratings & Reviews

No reviews available

Be the first to Write a Review