Thermo Scientific Orion VSTAR-RD VERSA STAR™ Dissolved Oxygen Module For VERSA STAR™ Meters
- VERSA STAR Dissolved Oxygen/RDO/Temperature module easily connects into VERSA STAR meters
- Dissolved Oxygen/RDO/Temperature module takes the worry out of DO probe compatibility – the meter accepts and automatically recognizes Orion polarographic and RDO optical/luminescence-based probes
- Compensates automatically for temperature, salinity with manual input and barometric pressure (automatic or manual)
- Allows for calibration using water-saturated air, air-saturated water, a Winkler titration, or zero point
- No need to turn off your meter to switch modules –meter automatically recognizes module changes
- Sold individually
- Manufacturer Part No: ORI-VSTAR-RD
IMAGE DISCLAIMER: We strive to show product images and descriptions as accurately as possible. However, images and descriptions may differ from the actual product being shipped. Prior to purchasing, please make sure that the manufacturer PART NUMBER displayed here matches the exact part number you wish to acquire. We apologize in advance, but returns or RMA’s are not permitted due to incorrect purchases made based on images or descriptions.
Details
This Thermo Scientific Orion VERSA STAR Dissolved Oxygen/RDO/Temperature module easily connects into VERSA STAR meters. The Dissolved Oxygen/RDO/Temperature module takes the worry out of DO probe compatibility – the meter accepts and automatically recognizes Orion polarographic and RDO optical/luminescence-based probes. It also compensates automatically for temperature, salinity with manual input and barometric pressure (automatic or manual) and allows for calibration using water-saturated air, air-saturated water, a Winkler titration or zero point. No need to turn off your meter to switch modules –meter automatically recognizes module changes. Temperature Mode Range: -5° to 105° (23° to 221°). Temperature Mode Resolution: 0.1 (0.1). Temperature Mode Relative Accuracy: ±0.1. DO Mode Concentration Range: Polarographic-- 0 to 90mg/L; RDO optical-- 0 to 50mg/L0.01, 0.1. DO Mode Concentration Resolution: 0.01, 0.1. DO Mode Relative Accuracy: Polarographic-- ±0.2mg/L; ±2%; RDO optical-- ±0.1mg/L up to 8mg/L, ±0.2mg/L up to 20mg/L, 10% of reading beyond; ±2%. DO Mode % Saturation Range: Polarographic-- 0 to 600; RDO optical--0 to 500. DO Mode % Saturation Resolution: 0.1, 1. DO Mode Salinity Factor: 0 to 45 ppt, manual; automatic if used with conductivity module (sold separately). DO Mode Calibration: Water-saturated air, air-saturated water, manual (Winkler) and zero point. Inputs: 9-pin mini-DIN. Sensor Types: Polarographic or RDO (optical/luminesce-based) DO. Environmental Operating Conditions Relative Humidity: 5 to 85% noncondensing. Thermo Scientific Orion #: VSTAR-RD.
Documents & Videos
This Thermo Scientific Orion VERSA STAR Dissolved Oxygen/RDO/Temperature module easily connects into VERSA STAR meters. The Dissolved Oxygen/RDO/Temperature module takes the worry out of DO probe compatibility – the meter accepts and automatically recognizes Orion polarographic and RDO optical/luminescence-based probes. It also compensates automatically for temperature, salinity with manual input and barometric pressure (automatic or manual) and allows for calibration using water-saturated air, air-saturated water, a Winkler titration or zero point. No need to turn off your meter to switch modules –meter automatically recognizes module changes. Temperature Mode Range: -5° to 105° (23° to 221°). Temperature Mode Resolution: 0.1 (0.1). Temperature Mode Relative Accuracy: ±0.1. DO Mode Concentration Range: Polarographic-- 0 to 90mg/L; RDO optical-- 0 to 50mg/L0.01, 0.1. DO Mode Concentration Resolution: 0.01, 0.1. DO Mode Relative Accuracy: Polarographic-- ±0.2mg/L; ±2%; RDO optical-- ±0.1mg/L up to 8mg/L, ±0.2mg/L up to 20mg/L, 10% of reading beyond; ±2%. DO Mode % Saturation Range: Polarographic-- 0 to 600; RDO optical--0 to 500. DO Mode % Saturation Resolution: 0.1, 1. DO Mode Salinity Factor: 0 to 45 ppt, manual; automatic if used with conductivity module (sold separately). DO Mode Calibration: Water-saturated air, air-saturated water, manual (Winkler) and zero point. Inputs: 9-pin mini-DIN. Sensor Types: Polarographic or RDO (optical/luminesce-based) DO. Environmental Operating Conditions Relative Humidity: 5 to 85% noncondensing. Thermo Scientific Orion #: VSTAR-RD.